← Back
Two family frame
39 WOODLAND AVENUE
STATEN ISLAND · Great Kills-Eltingville · BIN 5070498
💬 Discuss this project
1920Year Built
2.25Stories
B2Building Class
R2Zoning
2,650 sfGross Floor Area
2Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Two family frame · 8,220 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOTIR ASSOCIATES108/11/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RICHMOND ELEC'L CONTR'SElectrical103/22/2026
SUPERIOR PLUMBING & HEATINGPlumbing107/08/2026
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Inspection (4)Special Inspection (1)
11/26/2025
Violation issued (HPD, open)
I
09/22/2023
Signed off — Alteration
NEW GAS METER TO SEPARATE GAS SERVICE FOR EXISTING 2-FAMILY DWELLING UNITS. REMOVE EXISTING OIL BURNER * REPLACE WITH (2) NAVIAN TANKLESS BOILERS/HWHs.
S00785088-I1
09/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/14/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/14/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/30/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/08/2022
Permit issued — Plumbing
S00785088-I1-PL
08/11/2022
Filed — Alteration
NEW GAS METER TO SEPARATE GAS SERVICE FOR EXISTING 2-FAMILY DWELLING UNITS. REMOVE EXISTING OIL BURNER * REPLACE WITH (2) NAVIAN TANKLESS BOILERS/HWHs.
S00785088-I1
08/01/2022
Special inspection requirement — Energy Code Compliance Inspections
Hany Demetry
01/25/2011
Violation issued (ECB, closed)
Unknown
01/25/2011
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI09/08/2022
1 project · most recent 07/11/2022
FiledStatusContractorScope
07/11/2022CompleteRICHMOND ELEC'L CONTR'S3 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
09/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/14/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/14/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/30/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
08/01/2022Energy Code Compliance InspectionsHany Demetryprogress
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/24/2026S00785088-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/24/2026S00785088-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026S00785088-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/24/2026S00785088-I1Open ↗