← Back
Office with commercial, 1-6 stories
390 COURT STREET
💬 Discuss this project
1900Year Built
3Stories
O5Building Class
R6AZoning
—Gross Floor Area
4Units
0 Open Violations
Office with commercial, 1-6 stories · Owner of record: CARROLL COURT ASSOCIATES · 3 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 3Under Construction23p · 1 filing · 20 docs
Floor 2Under Construction9p · 2 filings · 20 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GREENBROOK PARTNERS1209/13/2026
CARROLL COURT ASSOCIATES LLC1103/22/2026
HKS CONSTRUCTION503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COMMERCIAL CONSTRUCTION CONSULTING704/09/2026
RIMKUS NEW YORK PLLC201/30/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EAST COAST EXPEDITING503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HARROW NY INCGeneral Contractor307/08/2026
TORRES IVANElectrical103/21/2026
JEM FIRE PREVENTION INCFire Protection107/15/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIMKUS NEW YORK, PLLC8123403/26/2026
RIMKUS NEW YORK, PLLC9809101/30/2026
Building Lifecycle
All (64)Filed (9)Permit Issued (5)Violation (2)Inspection (1)Objection (21)Special Inspection (26)
07/14/2026
Permit issued — Sprinklers
B01345444-S3-EW-SP
04/29/2026
Permit issued — Mechanical Systems
B01345455-S1-MS
04/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Kenneth Wagner
04/13/2026
Special inspection requirement — Maintenance information
Kenneth Wagner
04/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
04/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
04/13/2026
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
04/09/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-P2
04/09/2026
Permit issued — Plumbing
B01345444-S2-PL
04/08/2026
Objection resolved — Open
03/30/2026
Special inspection requirement — Maintenance information
Kenneth Wagner
03/30/2026
Special inspection requirement — Ventilation and air distribution system
Kenneth Wagner
03/27/2026
Objection raised — Other
03/27/2026
Objection resolved — Addressed
03/27/2026
Objection raised — Fire_Protection
03/26/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-P1
03/26/2026
Permit issued — Mechanical Systems
B01345444-S1-MS
03/24/2026
Special inspection requirement — Sprinkler Systems
Kenneth Wagner
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
03/16/2026
Filed — Alteration CO
Mechanical work associated with conversion of 2nd floor to residential use. No change in occupancy, use or egress.
B01345455-S2
03/16/2026
Filed — Alteration CO
Mechanical work associated with conversion of 2nd floor to residential use. No change in occupancy, use or egress.
B01345455-S1
03/03/2026
Permit issued — General Construction
B01345444-I1-GC
02/11/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-S2
02/11/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-S3
02/11/2026
Objection raised — Scope
02/11/2026
Objection raised — Other
02/11/2026
Objection raised — Scope
02/11/2026
Objection raised — Other
02/11/2026
Objection raised — Other
02/11/2026
Objection raised — Other
02/11/2026
Objection raised — Zoning
02/11/2026
Objection raised — Accessibility
02/11/2026
Objection raised — Accessibility
02/11/2026
Objection raised — Accessibility
02/11/2026
Objection raised — Fire_Protection
02/11/2026
Objection raised — Scope
01/30/2026
Filed — Alteration CO
Mechanical work associated with conversion of 2nd floor to residential use. No change in occupancy, use or egress.
B01345455-I1
01/30/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-S1
01/30/2026
Filed — Alteration
General construction associated with renovations to existing apartments on the 3rd fl. No change in occupancy, use or egress.
B01345444-I1
01/28/2026
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
01/28/2026
Special inspection requirement — Ventilation and air distribution system
Kenneth Wagner
01/28/2026
Special inspection requirement — Maintenance information
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
01/28/2026
Special inspection requirement — Mechanical Systems
Kenneth Wagner
01/28/2026
Special inspection requirement — Final
Kenneth Wagner
01/28/2026
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Kenneth Wagner
01/28/2026
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
01/28/2026
Special inspection requirement — Maintenance information
Kenneth Wagner
01/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedJEM FIRE PREVENTION INC07/14/2026
DOB NOWMechanical SystemsPermit IssuedHARROW NY INC04/29/2026
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP04/09/2026
DOB NOWMechanical SystemsSigned-offHARROW NY03/26/2026
DOB NOWGeneral ConstructionPermit IssuedHARROW NY03/03/2026
BISOTISSUEDHKS CONSTRUCTION CORP11/02/2016
BISEQISSUEDHKS CONSTRUCTION CORP09/20/2016
BISMHISSUEDTOTO + VUJINOVIC ARCHITECTS03/16/2007
BIS—ISSUEDNATIONAL MAINTENANCE INC06/19/2006
BIS—ISSUEDNATIONAL MAINTENANCE INC06/19/2006
BISPLISSUEDPAR PLUMBING CO., INC04/24/2006
BISOTISSUEDCANDOR CONST GROUP03/16/2006
BISEQISSUEDCANDOR CONST GROUP03/16/2006
BISEQISSUEDBIANCHI & SON CONTRACTING CORP09/20/1996
2 projects · most recent 04/09/2026
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/09/2026Signed-offHARROW NY INCHeating Systems, Ventilation Systems
Heating
Stelpro Stelpro Model #AB61508W 1,500 kW · Electric Heater ×16
Stelpro Model # AB0758W 750 kW · Electric Heater ×5
Stelpro Model #AB0508W 500 kW · Electric Heater ×5
Stelpro Model #Ass01502T2W 1,500 kW · Electric Heater ×2
Ventilation
Panasonic Panasonic Model # FV-0511VF1 50 CFM · Exhaust Fan ×2
Panasonic Model #FV-10VEC2RH 64 CFM · Erv ×1
03/16/2026Permit IssuedHARROW NY INCHeating Systems, Ventilation Systems
Heating
Stelpro Stelpro Model #AB61508W 2 kW · Electric Heater ×9
Stelpro Model #AB0758W 750 kW · Electric Heater ×7
Stelpro Model # 500 kW · Electric Heater ×4
Ventilation
Panasonic Panasonic Model #FV-0511VF1 50 CFM · Exhaust Fan ×4
Panasonic Model #FV-10VEC2RH 64 CFM · Erv ×1
1 project · most recent 04/09/2026
FiledStatusContractorScope
04/09/2026Permit IssuedJEM FIRE PREVENTION INC52 heads
2 projects · most recent 04/09/2026
Water/Sanitary
FiledStatusContractorScope
04/09/2026Permit IssuedTRI CITY MECHANICAL GROUPWater/Sanitary
03/16/2026——Water/Sanitary
1 project · most recent 06/30/2026
General Wiring
FiledStatusContractorScope
06/30/2026Permit IssuedE & M ELECTRICAL NY CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
04/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
04/13/2026HVAC-R and service water piping design and insulationKenneth Wagnerenergy_progress
04/13/2026Maintenance informationKenneth Wagnerenergy_progress
04/13/2026HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
04/13/2026HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
04/13/2026Energy Code Compliance InspectionsKenneth Wagnerprogress
03/30/2026Maintenance informationKenneth Wagnerenergy_progress
03/30/2026Ventilation and air distribution systemKenneth Wagnerenergy_progress
03/24/2026Sprinkler SystemsKenneth Wagnerspecial
01/28/2026Energy Code Compliance InspectionsKenneth Wagnerprogress
01/28/2026Ventilation and air distribution systemKenneth Wagnerenergy_progress
01/28/2026Maintenance informationKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
01/28/2026Mechanical SystemsKenneth Wagnerspecial
01/28/2026FinalKenneth Wagnerprogress
01/28/2026Energy Code Compliance InspectionsKenneth Wagnerprogress
01/28/2026HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water piping design and insulationKenneth Wagnerenergy_progress
01/28/2026Energy Code Compliance InspectionsKenneth Wagnerprogress
01/28/2026HVAC-R and service water piping design and insulationKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
01/28/2026Maintenance informationKenneth Wagnerenergy_progress
01/28/2026HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
01/28/2026Mechanical SystemsKenneth Wagnerspecial
Latest 25 of 26.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/18/2026B01345444-S3Request digital key ↗
08/18/2026B01345444-P1Request digital key ↗
08/18/2026B01345444-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸BISWORK PERMIT APPLICATION2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸Seals & Professional Certifications39
▸DOB NOWProgress Inspector Seal & Signature23
09/23/2026B01345444-S1Open ↗
09/23/2026B01345444-S1Open ↗
09/23/2026B01345444-S1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/18/2026B01345444-P1Open ↗
08/18/2026B01345444-S2Open ↗
08/18/2026B01345444-S3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01345444-S1Open ↗
08/28/2026B01345455-S1Open ↗
08/26/2026B01345444-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/10/2017340422910Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01345455-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026B01345444-S1Open ↗
08/18/2026B01345444-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/25/2016340436488Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/25/2016340436488Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/10/2017340422910Open ↗
▸Cost, Insurance & Ownership3
▸BISCIVIL PENALTY AFFADAVIT/REQUEST2
11/02/2016340436488Open ↗
09/19/2016340422910Open ↗
▸BISCOST AFFIDAVIT1
10/25/2016340436488Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET2
10/25/2016340436488Open ↗
09/15/2016340422910Open ↗
▸Other Documents1
▸DOB NOWFinal Survey1
08/13/2026B01345455-I1Open ↗