← Back
Primarily 1 family with 1 store or office
391 KINGSTON AVENUE
BROOKLYN · Crown Heights (South) · BIN 3034313
💬 Discuss this project
1925Year Built
2Stories
S1Building Class
R5Zoning
2,400 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Primarily 1 family with 1 store or office · Owner of record: KTG KINGSTON LLC · 2,800 sf lot · 0.86 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Floor 224p · 1 filing · 20 docs
Floor 122p · 1 filing · 20 docs
Cellar24p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KTG KINGSTON LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADVANCED ENGINEERING & INSPECT. PLL908/16/2023
JOHN SCHIMENTI, P.C. ARCHITECT212/29/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY EXPEDITING2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PROMPT BUILDERS NY INCGeneral Contractor307/08/2026
S & J INDUSTRIAL CORPFire Protection107/08/2026
P.H. WORKS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI10081108/16/2023
Building Lifecycle
All (118)Filed (11)Permit Issued (4)Signed Off (3)Violation (3)Inspection (9)Objection (58)Special Inspection (30)
10/16/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-S2
10/13/2023
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
10/13/2023
Special inspection requirement — Maintenance information
GLEN LANGER
10/13/2023
Special inspection requirement — Shutoff dampers
GLEN LANGER
10/13/2023
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
10/13/2023
Special inspection requirement — Heating Systems
GLEN LANGER
10/13/2023
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
10/13/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
10/13/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
10/13/2023
Special inspection requirement — Mechanical Systems
GLEN LANGER
10/13/2023
Special inspection requirement — Final
GLEN LANGER
09/28/2023
Objection resolved — Addressed
09/28/2023
Objection resolved — Addressed
08/24/2023
Objection raised — Other
08/21/2023
Objection raised — Scope
08/16/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P7
08/16/2023
Special inspection requirement — Final
GLEN LANGER
08/16/2023
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
08/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
08/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
08/16/2023
Special inspection requirement — Shutoff dampers
GLEN LANGER
08/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
08/16/2023
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
08/16/2023
Special inspection requirement — Heating Systems
GLEN LANGER
08/16/2023
Special inspection requirement — Maintenance information
GLEN LANGER
08/16/2023
Special inspection requirement — Mechanical Systems
GLEN LANGER
08/08/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-S4
07/17/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/07/2023
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
07/07/2023
Special inspection requirement — Maintenance information
GLEN LANGER
07/07/2023
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
07/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
07/07/2023
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
07/07/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
07/06/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P6
06/21/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-S3
06/19/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
06/19/2023
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
06/19/2023
Special inspection requirement — Maintenance information
GLEN LANGER
06/19/2023
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
06/16/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/24/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/22/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/22/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/11/2023
Objection resolved — Addressed
05/01/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/24/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/18/2023
Objection raised — Admin
04/17/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P5
04/04/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P4
12/29/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P2
12/29/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P3
12/29/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-P1
09/21/2022
Permit issued — Mechanical Systems
B00656384-S2-MS
08/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/26/2022
Permit issued — Plumbing
B00656384-S4-PL
07/01/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-S4
06/23/2022
Permit issued — Sprinklers
B00656384-S3-EW-SP
06/07/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed Combine tax lots 7 & 8 - change of use with Minor partitions work and lighting as per plan
B00656384-S3
Latest 60 of 118 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPROMPT BUILDERS NY INC09/21/2022
DOB NOWPlumbingSigned-offP.H. WORKS INC07/26/2022
DOB NOWSprinklersSigned-offS & J INDUSTRIAL CORP06/23/2022
DOB NOWGeneral ConstructionPermit IssuedPROMPT BUILDERS NY INC05/17/2022
BISPLISSUEDFERNANDEZ HTG & MECH CORP.05/09/2013
BISOTISSUEDPHEN-TECH CONSTRUCTI AND05/09/2013
BISOTISSUEDY.H.S. CONSTRUCTION CORP06/20/2005
BISOTISSUEDY.H.S. CONSTRUCTION CORP01/03/2005
BISOTISSUEDBONYITZ05/28/1999
1 project · most recent 08/16/2023
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/16/2023Signed-offPROMPT BUILDERS NY INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Carrier 24ABB360A520 5 tons · Condensing Unit ×4
24abb360a0052011 5 tons · Condensing Unit ×4
Mitsubishi Electric SUZ-KA09NA2 9,500 BTU · Condensing Unit ×3
Ventilation
Captiveaire A2-D.500-20D-MPU 4,960 CFM · Makeup Air ×6
1 project · most recent 08/16/2023
Sprinkler System
FiledStatusContractorScope
08/16/2023Signed-offS & J INDUSTRIAL CORPSprinkler System
1 project · most recent 08/16/2023
Gas Water/Sanitary
FiledStatusContractorScope
08/16/2023Signed-offP.H. WORKS INCGas, Water/Sanitary
1 project · most recent 04/18/2023
General Wiring
FiledStatusContractorScope
04/18/2023CompleteCONTACT ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/17/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/19/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/16/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/24/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/22/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/22/2023Pass-Final CND-Occupancy InspectionPassView ↗
05/01/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/24/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
08/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 61
DateRequirementInspectorRole
10/13/2023Heating SystemsGLEN LANGERspecial
10/13/2023Fire-Resistant Penetrations and JointsGLEN LANGERspecial
10/13/2023HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
10/13/2023HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
10/13/2023Maintenance informationGLEN LANGERenergy_progress
10/13/2023HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
10/13/2023Shutoff dampersGLEN LANGERenergy_progress
10/13/2023FinalGLEN LANGERprogress
10/13/2023Energy Code Compliance InspectionsGLEN LANGERprogress
10/13/2023Mechanical SystemsGLEN LANGERspecial
08/16/2023Shutoff dampersGLEN LANGERenergy_progress
08/16/2023HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
08/16/2023Mechanical SystemsGLEN LANGERspecial
08/16/2023Energy Code Compliance InspectionsGLEN LANGERprogress
08/16/2023FinalGLEN LANGERprogress
08/16/2023Maintenance informationGLEN LANGERenergy_progress
08/16/2023HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
08/16/2023HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
08/16/2023Fire-Resistant Penetrations and JointsGLEN LANGERspecial
08/16/2023Heating SystemsGLEN LANGERspecial
07/07/2023Maintenance informationGLEN LANGERenergy_progress
07/07/2023HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
07/07/2023HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
07/07/2023HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
07/07/2023Energy Code Compliance InspectionsGLEN LANGERprogress
Latest 25 of 61.
▾Documents — 82 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/29/2026B00656384-P4Request digital key ↗
08/29/2026B00656384-P3Request digital key ↗
08/29/2026B00656384-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
02/15/2023340047005Open ↗
02/15/2023300864866Open ↗
10/05/2013340047005Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
05/09/2013340047005Open ↗
05/09/2013340047005Open ↗
04/30/2013340047005Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00656384-I1Open ↗
▸Seals & Professional Certifications37
▸DOB NOWProgress Inspector Seal & Signature14
09/02/2026B00656384-P4Open ↗
09/02/2026B00656384-P4Open ↗
09/01/2026B00656384-P7Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/29/2026B00656384-P4Open ↗
08/29/2026B00656384-P3Open ↗
08/29/2026B00656384-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/02/2026B00656384-P4Open ↗
09/01/2026B00656384-P7Open ↗
08/27/2026B00656384-S2Open ↗
Showing 3 of 9 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/22/2013340047005Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/22/2013340047005Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/22/2013340047005Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
10/05/2013340047005Open ↗
03/22/2013340047005Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/29/2026B00656384-P3Open ↗
08/29/2026B00656384-P2Open ↗
08/29/2026B00656384-P1Open ↗
Showing 3 of 11 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/22/2013340047005Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/22/2013340047005Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/22/2013340047005Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00656384-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/22/2013340047005Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/22/2013340047005Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
10/23/2013340047005Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/22/2013340047005Open ↗
▸Other Documents5
▸DOB NOWSite Survey: Initial2
08/13/2026B00656384-P3Open ↗
08/13/2026B00656384-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/29/2026B00656384-P3Open ↗
08/14/2026B00656384-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00656384-I1Open ↗