← Back
BuildNYC
Four families
391 LEWIS AVENUE
BROOKLYN · BIN 3046788
💬 Discuss this project
1891Year Built
4Stories
C3Building Class
R6BZoning
6,000 sfGross Floor Area
4Units
Rent Stabilized1 Active Violation ▸FDNY Report ↗
Four families · Owner of record: 391 Lewis · 1,800 sf lot · 3.33 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofCold water and sanitary piping installation27p · 2 filings · 20 docs
Floor 4Cold water and sanitary piping installation21p · 2 filings · 20 docs
Floor 3Cold water and sanitary piping installation21p · 2 filings · 20 docs
Floor 2Cold water and sanitary piping installation22p · 2 filings · 20 docs
Floor 1Cold water and sanitary piping installation22p · 2 filings · 20 docs
CellarCold water and sanitary piping installation21p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
267 Kosciuszko2407/08/2026
391 Lewis103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/30/2023$3.2M—Private party → 391 LEWIS LLC$533/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Chun Engineering Consultant704/15/2024
Robert Siqeca PE107/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Cavalry1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Badger ManagementGeneral Contractor507/08/2026
PipestylistsPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. International Engineering3129804/15/2024
Building Lifecycle
05/05/2026
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
06/10/2025
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
11/29/2024
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
09/19/2024
Signed off — Alteration
STRUCTURAL PLANS AND SPECIFICATIONS IN CONJUNCTION WITH ALT 2 APPLICATION B00809523-I1 FOR INTERIOR RENOVATION ON EXISTING 4 STORY 4 FAMILY BLDG
B00809523-I1
09/05/2024
Signed off — Alteration
STRUCTURAL PLANS AND SPECIFICATIONS IN CONJUNCTION WITH ALT 2 APPLICATION B00809523-I1 FOR INTERIOR RENOVATION ON EXISTING 4 STORY 4 FAMILY BLDG
B00809523-S2
68 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offBadger Management08/22/2023
DOB NOWMechanical SystemsSigned-offBadger Management08/22/2023
DOB NOWPlumbingSigned-offT & T Plumbing08/10/2023
DOB NOWGeneral ConstructionSigned-offBadger Management08/10/2023
1 project · most recent 04/15/2024
Heating and Air Conditioning Systems
FiledStatusContractorScope
04/15/2024Signed-offBadger ManagementHeating and Air Conditioning Systems
1 project · most recent 11/14/2023
General Wiring
FiledStatusContractorScope
11/14/2023CompleteE & M Electrical NYGeneral Wiring
1 project · most recent 04/15/2024
Steel Wood
FiledStatusContractorScope
04/15/2024Signed-offBadger ManagementSteel, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/13/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
02/13/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/27/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/27/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/27/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
04/16/2024Fire-Resistance Rated ConstructionNANIK MASSANDprogress
04/16/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
04/16/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
04/16/2024FinalNANIK MASSANDprogress
04/16/2024Lighting in dwelling unitsNANIK MASSANDenergy_progress
04/11/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
04/11/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
04/11/2024FinalNANIK MASSANDprogress
04/11/2024Fire-Resistance Rated ConstructionNANIK MASSANDprogress
04/11/2024Lighting in dwelling unitsNANIK MASSANDenergy_progress
11/06/2023HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
11/06/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
11/06/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
11/06/2023FinalNANIK MASSANDprogress
11/06/2023Fire-Resistance Rated ConstructionNANIK MASSANDprogress
11/06/2023Lighting in dwelling unitsNANIK MASSANDenergy_progress
11/06/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
11/06/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
11/06/2023Maintenance informationNANIK MASSANDenergy_progress
11/06/2023HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
11/06/2023HVAC-R and service water piping design and insulationNANIK MASSANDenergy_progress
07/19/2023Energy Code Compliance InspectionsNANIK MASSANDprogress
07/19/2023HVAC-R and service water heating equipmentNANIK MASSANDenergy_progress
07/19/2023Maintenance informationNANIK MASSANDenergy_progress
07/19/2023HVAC-R and service water heating system controlsNANIK MASSANDenergy_progress
Latest 25 of 33.
61 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account