← Back
Two stories - detached, small or mid-size
3916 KINGS HIGHWAY
BROOKLYN · Flatlands · BIN 3217226
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R5Zoning
2,796 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: LIFESPIRE, INC. · 8,680 sf lot · 0.32 FAR built · Flood zone X500
Locations of Work
Plumbing
Cellar4p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LIFESPIRE INC.1103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEMS ENGINEERING AND CONSTRUCTION201/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEWSAN CONSULTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TAVELLA PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781201/14/2022
Building Lifecycle
All (15)Filed (2)Permit Issued (1)Violation (1)Inspection (4)Special Inspection (7)
03/01/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/28/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/23/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/11/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/19/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
01/19/2022
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
01/19/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Bendoraitis
01/19/2022
Special inspection requirement — HVAC-R and service water heating equipment
Steven Bendoraitis
01/19/2022
Special inspection requirement — HVAC-R and service water heating system controls
Steven Bendoraitis
01/19/2022
Special inspection requirement — Permanent certificate
Steven Bendoraitis
01/19/2022
Special inspection requirement — Maintenance information
Steven Bendoraitis
01/14/2022
Filed — Alteration
Replace gas-fired boiler and two (2) gas fired water heaters. Register one (1) dryer. Perform corrective work to comply with ECB violation 32052578J.
B00623397-P1
12/01/2021
Permit issued — Plumbing
B00623397-I1-PL
11/24/2021
Filed — Alteration
Replace gas-fired boiler and two (2) gas fired water heaters. Register one (1) dryer. Perform corrective work to comply with ECB violation 32052578J.
B00623397-I1
09/18/2007
Violation issued (ECB, open)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offTAVELLA PLBG & HTG CORP12/01/2021
BISPLISSUEDTOWER PLUMBING & HTG CORP06/23/2010
1 project · most recent 01/14/2022
Gas
FiledStatusContractorScope
01/14/2022Signed-offTAVELLA PLBG & HTG CORPGas
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/01/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/28/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/23/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/11/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
01/19/2022Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
01/19/2022Energy Code Compliance InspectionsSteven Bendoraitisprogress
01/19/2022HVAC-R and service water piping design and insulationSteven Bendoraitisenergy_progress
01/19/2022HVAC-R and service water heating equipmentSteven Bendoraitisenergy_progress
01/19/2022HVAC-R and service water heating system controlsSteven Bendoraitisenergy_progress
01/19/2022Permanent certificateSteven Bendoraitisenergy_progress
01/19/2022Maintenance informationSteven Bendoraitisenergy_progress
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/31/2026B00623397-P1Request digital key ↗
08/31/2026B00623397-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
11/01/2010320164362Open ↗
09/27/2010320164353Open ↗
05/11/2010320164353Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
06/23/2010320164362Open ↗
05/21/2010320164362Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026B00623397-I1Open ↗
08/31/2026B00623397-I1Open ↗
08/31/2026B00623397-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
02/28/2011320164362Open ↗
05/11/2010320164353Open ↗
05/11/2010320164362Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/31/2026B00623397-P1Open ↗
08/31/2026B00623397-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026B00623397-I1Open ↗
▸Trade Schedules & Equipment9
▸BISSELF-CERT PLUMBING NOTICE7
01/24/2011320164362Open ↗
12/29/2010320164362Open ↗
12/10/2010320164362Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING2
11/01/2010320164362Open ↗
05/11/2010320164362Open ↗
▸Environmental & Asbestos5
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
05/24/2010320164362Open ↗
05/11/2010320164353Open ↗
05/11/2010320164362Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/31/2026B00623397-P1Open ↗
08/31/2026B00623397-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS2
05/11/2010320164353Open ↗
05/11/2010320164362Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/28/2011320164362Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
02/28/2011320164362Open ↗
05/11/2010320164353Open ↗
05/11/2010320164362Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
05/11/2010320164353Open ↗
05/11/2010320164362Open ↗