← Back
Two family converted from one family
394 6 STREET
BROOKLYN · BIN 3021663
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
2,400 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family converted from one family · 2,000 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/28/2016$2.2M—Private party → Private party$927/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC101/02/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYS ESSENTIAL POWER INCGeneral Contractor303/21/2026
ANTONIO CERIELLOElectrical103/21/2026
CERIELLO ANTONIOElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854101/02/2024
Building Lifecycle
All (26)Filed (1)Permit Issued (1)Signed Off (1)Violation (2)Objection (16)Special Inspection (5)
05/10/2024
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
B00984172-I1
02/01/2024
Permit issued — Solar
B00984172-I1-SL
01/29/2024
Objection resolved — Addressed
01/24/2024
Objection resolved — Addressed
01/24/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/22/2024
Objection resolved — Addressed
01/16/2024
Objection raised — Admin
01/08/2024
Objection raised — Structural
01/08/2024
Objection raised — Zoning
01/08/2024
Objection raised — Structural
01/08/2024
Objection raised — Other
01/08/2024
Objection raised — Other
01/08/2024
Objection raised — Other
01/08/2024
Objection raised — Structural
01/02/2024
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
B00984172-I1
01/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
01/02/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
01/02/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
01/02/2024
Special inspection requirement — Final
TOM PETERSEN
01/02/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
06/29/2018
Violation issued (ECB, closed)
Construction
12/08/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYS ESSENTIAL POWER INC02/01/2024
BISMHISSUEDJDP DESIGN CONSTRUCTION I11/14/2019
BISPLISSUEDVENDOLA INC07/10/2019
BISOTISSUEDJDP DESIGN CONSTRUCTION I05/13/2019
BISPLISSUEDVENDOLA INC06/19/2018
BISOTISSUEDJDP DESIGN CONSTRUCTION I05/04/2018
BISOTISSUEDSHAMROCKIN PAINTING AND03/31/2017
BISPLISSUEDVENDOLA INC03/17/2017
BISOTISSUEDSHAMROCKIN PAINTING AND02/16/2017
1 project · most recent 01/07/2024
FiledStatusContractorScope
01/07/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/02/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
01/02/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
01/02/2024Energy Code Compliance InspectionsTOM PETERSENprogress
01/02/2024FinalTOM PETERSENprogress
01/02/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026B00984172-I1Request digital key ↗
▸Applications & Permits18
▸BISWORK PERMIT APPLICATION11
11/15/2019321516971Open ↗
11/15/2019321516971Open ↗
05/28/2019321516971Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION5
10/17/2017321516971Open ↗
10/17/2017321516971Open ↗
10/06/2017321516971Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
10/11/2017321516971Open ↗
02/07/2017321516971Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026B00984172-I1Open ↗
08/30/2026B00984172-I1Open ↗
08/30/2026B00984172-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
02/07/2017321516971Open ↗
02/07/2017321516971Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026B00984172-I1Open ↗
08/30/2026B00984172-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/07/2017321516971Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/07/2017321516971Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00984172-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
10/11/2017321516971Open ↗
02/07/2017321516971Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes2
02/07/2017321516971Open ↗
02/07/2017321516971Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/07/2017321516971Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00984172-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/07/2017321516971Open ↗
▸Approvals, Objections & Sign-offs2
▸BISSUPERSEDING LETTER1
05/07/2018321516971Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B00984172-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/07/2017321516971Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
10/11/2017321516971Open ↗
▸BISEFILING COVER SHEET1
02/07/2017321516971Open ↗