| Owner | Filings | Most Recent |
|---|---|---|
| 198 SHEFA | 24 | 09/13/2026 |
| PARK CONTRACTING GROUP | 4 | 04/09/2026 |
| MNK ENTERPRISES NY | 5 | 04/09/2026 |
| DOUGLASS BAPAZ, LLC | 2 | 03/22/2026 |
| MORELL BUILDERS | 9 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/18/2022 | $1.7M | — | Private party → DOUGLASS BAPAZ, LLC | $1,079/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| MICHAEL SCADUTO ARCHITECT | 4 | 07/22/2026 |
| JOSE L. PENA,P.E. | 13 | 06/09/2026 |
| ASHRAF CORP | 1 | 07/31/2025 |
| MSM ENGINEERING SERVICES, PLLC | 1 | 01/06/2025 |
| AA BLDG & INSP SVC LLC | 2 | 11/01/2023 |
| WAVIC ENGINEERING PLLC | 1 | 12/01/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| A&A BUILDING CONSULTANTS INC. | 26 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| YAFE MEOD CORP | General Contractor | 9 | 07/08/2026 |
| MORELL BUILDERS INC | General Contractor | 4 | 07/08/2026 |
| R.A.B. CONSTRUCTION CORP | General Contractor | 2 | 07/08/2026 |
| MOKEN HOME IMPROVEMENT | General Contractor | 2 | 04/09/2026 |
| PARK CONTRACTING GROUP | General Contractor | 2 | 04/09/2026 |
| LG ELITE PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| MNK ENTERPRISES NY INC | General Contractor | 1 | 04/09/2026 |
| STELLAR INDUSTRIES INC | General Contractor | 1 | 04/09/2026 |
| ALL PRO PLBG & HTG INC | Plumbing | 1 | 07/08/2026 |
| ALL PRO PLBG & HTG INC | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MICHAEL SCADUTO ARCHITECT | 4833 | 8 | 07/22/2026 |
| AA BUILDING & INSPECTION | 1519 | 6 | 03/26/2025 |
| IP CONCRETE TESTING AND I | 6252 | 1 | 11/01/2023 |
| CL ENGINEERING P.C. | 6781 | 2 | 12/01/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Signed-off | YAFE MEOD CORP | 02/17/2026 |
| DOB NOW | Structural | Permit Issued | YAFE MEOD CORP | 02/17/2026 |
| DOB NOW | Sprinklers | Signed-off | ALL PRO PLBG & HTG INC | 01/07/2026 |
| DOB NOW | Plumbing | Signed-off | ALL PRO PLBG & HTG INC | 11/07/2025 |
| DOB NOW | Supported Scaffold | Signed-off | PARK CONTRACTING GROUP | 09/12/2025 |
| DOB NOW | Structural | Permit Issued | YAFE MEOD CORP | 07/28/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | PARK CONTRACTING GROUP | 07/10/2025 |
| DOB NOW | Plumbing | Signed-off | LG ELITE PLUMBING INC | 06/12/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | MNK ENTERPRISES NY INC | 01/30/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | YAFE MEOD CORP | 12/20/2024 |
| DOB NOW | Construction Fence | Signed-off | YAFE MEOD CORP | 12/19/2024 |
| DOB NOW | Support of Excavation | Signed-off | MOKEN HOME IMPROVEMENT | 02/20/2024 |
| DOB NOW | Support of Excavation | Signed-off | MOKEN HOME IMPROVEMENT | 02/01/2024 |
| DOB NOW | General Construction | Signed-off | MORELL BUILDERS INC | 10/27/2023 |
| DOB NOW | General Construction | Signed-off | R.A.B. CONSTRUCTION CORP | 08/29/2023 |
| DOB NOW | General Construction | Signed-off | STELLAR INDUSTRIES INC | 07/21/2023 |
| DOB NOW | General Construction | Signed-off | R.A.B. CONSTRUCTION CORP | 05/27/2022 |
| DOB NOW | General Construction | Signed-off | MORELL BUILDERS INC | 05/10/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/22/2026 | Permit Issued | YAFE MEOD CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Rheem RA1342AJ1NA 42,000 BTU · Condensing Unit ×8 Ventilation Hampton Bay 7114-01 100 CFM · Exhaust Fan ×20 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/01/2022 | Signed-off | ALL PRO PLBG & HTG INC | 24 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/09/2026 | Signed-off | ALL PRO PLBG & HTG INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/25/2026 | Permit Issued | ACCURATE ELEC'L CORP. | General Wiring |
| 01/31/2025 | Complete | RICHARD NEU | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/22/2026 | Permit Issued | YAFE MEOD CORP | Steel, Concrete, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/13/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/15/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/22/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/03/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/18/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 11/14/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 11/14/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/14/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 11/12/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/28/2026 | Insulation placement and R values | Michael Scaduto | energy_progress |
| 07/28/2026 | Permanent certificate | Michael Scaduto | energy_progress |
| 07/28/2026 | Air barrier — testing | Michael Scaduto | energy_progress |
| 07/28/2026 | Footing and Foundation | Michael Scaduto | progress |
| 07/28/2026 | Fire-Resistance Rated Construction | Michael Scaduto | progress |
| 07/28/2026 | Final | Michael Scaduto | progress |
| 07/28/2026 | Energy Code Compliance Inspections | Michael Scaduto | progress |
| 07/28/2026 | Excavations - Sheeting, Shoring, and Bracing | Michael Scaduto | special |
| 07/28/2026 | Structural Steel - Details | Michael Scaduto | special |
| 07/28/2026 | Mechanical Systems | Michael Scaduto | special |
| 07/28/2026 | Structural Stability – Alterations of existing buildings | Michael Scaduto | special |
| 07/28/2026 | Heating Systems | Michael Scaduto | special |
| 07/28/2026 | Fire-Resistant Penetrations and Joints | Michael Scaduto | special |
| 07/28/2026 | Concrete - Cast-In-Place | Michael Scaduto | special |
| 07/28/2026 | Masonry | Michael Scaduto | special |
| 07/28/2026 | Construction Operations Influencing Adjacent Structures | Michael Scaduto | special |
| 07/28/2026 | Post-installed Anchors | Michael Scaduto | special |
| 07/28/2026 | Subgrade Inspections | Michael Scaduto | special |
| 07/28/2026 | Structural Cold-Formed Steel | Michael Scaduto | special |
| 07/28/2026 | HVAC-R and service water heating equipment | Michael Scaduto | energy_progress |
| 07/28/2026 | Air barrier - visual inspection | Michael Scaduto | energy_progress |
| 07/28/2026 | Maintenance information | Michael Scaduto | energy_progress |
| 07/28/2026 | Fenestration air leakage | Michael Scaduto | energy_progress |
| 07/28/2026 | Fenestration and door U-factor and product ratings | Michael Scaduto | energy_progress |
| 07/28/2026 | HVAC-R and service water heating system controls | Michael Scaduto | energy_progress |