← Back
Elevator apt, semi-fireproof with stores
The Westmark
395 CARROLL ST · BIN 3430171
💬 Discuss this project
2023Year Built
23Stories
D7Building Class
M1-4/R7-2Zoning
1,241,869 sfGross Floor Area
1,651Units
3 Open Violations 1 unresolved · 2 paperwork only ▸FDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: PRESIDENT UNION LLC · 43,020 sf lot · 28.87 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction13p · 4 filings · 20 docs
Bulkhead1p · 1 filing · 5 docs
Floor 23Under Construction13p · 3 filings · 20 docs
Floor 22Under Construction13p · 3 filings · 20 docs
Floor 21Under Construction13p · 3 filings · 20 docs
Floor 20Under Construction13p · 3 filings · 20 docs
Floor 19Under Construction13p · 3 filings · 20 docs
Floor 18Under Construction13p · 3 filings · 20 docs
Floor 17Under Construction13p · 3 filings · 20 docs
Floor 16Under Construction13p · 3 filings · 20 docs
Floor 15Under Construction13p · 3 filings · 20 docs
Floor 14Under Construction13p · 3 filings · 20 docs
Floor 13Under Construction13p · 3 filings · 20 docs
Floor 12Under Construction13p · 4 filings · 20 docs
Floor 11Under Construction13p · 3 filings · 20 docs
Floor 10Under Construction13p · 3 filings · 20 docs
Floor 9Under Construction13p · 3 filings · 20 docs
Floor 8Under Construction13p · 3 filings · 20 docs
Floor 7Under Construction13p · 3 filings · 20 docs
Floor 6Under Construction13p · 2 filings · 20 docs
Floor 5Under Construction13p · 3 filings · 20 docs
Floor 4Under Construction13p · 2 filings · 20 docs
Floor 3Under Construction12p · 2 filings · 20 docs
Floor 2Under Construction12p · 3 filings · 20 docs
Floor 1Under Construction13p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SKY EQUITY GROUP10507/08/2026
GALAXY DEVELOPERS2407/08/2026
SKY CONSTRUCTION NY1303/22/2026
PRESIDENT UNION LLC103/22/2026
SKY CONSTRUCTION CORP.203/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BAC Developers Group1703/21/2026
SYNERGY BUILDING CONSULTANTS1303/21/2026
HIERARCH-E203/21/2026
Rigid Structural Design, LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SKY CONSTRUCTION NY INCGeneral Contractor2807/08/2026
COLGATE ENTERPRISE CORPGeneral Contractor2307/08/2026
SAFETY FIRE SPRINKLER CORPFire Protection707/08/2026
MPI PLUMBING CORPPlumbing207/08/2026
KMI INCGeneral Contractor203/21/2026
SHTEIERMAN AVIGeneral Contractor103/21/2026
SAFETY FIRE SPRINKLER CORGeneral Contractor103/21/2026
CELTIC SERVICES NYC INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BIG APPLE GROUP NY A RMA91681605/01/2026
URBAN INTEGRATIONS LLC7993112/18/2024
TOHFAZ UDDIN P.E.2001309/25/2024
Building Lifecycle
All (188)Filed (33)Permit Issued (44)Signed Off (10)Violation (13)Inspection (24)Objection (34)Special Inspection (30)
08/06/2026
Signed off — Alteration
B01293887-I1
07/30/2026
Signed off — Alteration
B00690563-I1
07/30/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/30/2026
Permit issued — Mechanical Systems
B01381214-I1-MS
06/09/2026
Signed off — Alteration
B01002131-I1
06/09/2026
Signed off — Alteration
Installation of temporary overhead protection per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B01002120-I1
06/08/2026
Signed off — Alteration
Installation of temporary needle beam per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B01002137-I1
06/08/2026
Signed off — Alteration
Installation of temporary heavy duty sidewalk shed per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B00979051-I1
06/08/2026
Signed off — Alteration
Installation of temporary supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
B00987973-I1
05/04/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/01/2026
Filed — Alteration
INSTALLATION OF EMERGENCY GENERATOR WITH FUEL STORAGE.
B01381214-I1
03/31/2026
Special inspection requirement — Mechanical Systems
SOORJBALLY HARILALL
03/31/2026
Special inspection requirement — Final
SOORJBALLY HARILALL
03/23/2026
Objection resolved — Addressed
03/13/2026
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
03/13/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/13/2026
Inspection — Certified StandPipe-Fire Pump (SD)-Fire Pump Test
Certified
View inspection ↗
03/13/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
03/09/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/03/2026
Objection raised — Other
03/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Standpipe Systems
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Energy Code Compliance Inspections
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Sprinkler Systems
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Electrical motors and elevators
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Post-installed Anchors
SOORJBALLY HARILALL
03/03/2026
Special inspection requirement — Maintenance information
SOORJBALLY HARILALL
02/12/2026
Objection resolved — Addressed
02/10/2026
Objection raised — Other
02/05/2026
Filed — New Building
Plumbing, Sprinkler & Standpipe filed in conjunction with NB Job Number B00645244.
B00645244-A1
02/02/2026
Filed — New Building
Plumbing, Sprinkler & Standpipe filed in conjunction with NB Job Number B00645244.
B00645244-P8
02/02/2026
Special inspection requirement — Standpipe Systems
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Energy Code Compliance Inspections
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Post-installed Anchors
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Sprinkler Systems
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Maintenance information
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — Electrical motors and elevators
SOORJBALLY HARILALL
02/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
SOORJBALLY HARILALL
01/31/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/26/2025
Permit issued — Plumbing
B00645244-S6-PL
12/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/16/2025
Permit issued — Mechanical Systems
B00645244-S5-MS
12/09/2025
Permit issued — General Construction
B00645244-I1-GC
12/09/2025
Special inspection requirement — HVAC-R and service water heating equipment
Soorjbally Harilall
12/09/2025
Special inspection requirement — Mechanical Systems
SOORJBALLY HARILALL
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SOORJBALLY HARILALL
12/09/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Soorjbally Harilall
12/09/2025
Special inspection requirement — HVAC-R and service water heating system controls
Soorjbally Harilall
12/09/2025
Special inspection requirement — Final
Soorjbally Harilall
11/25/2025
Filed — New Building
Plumbing, Sprinkler & Standpipe filed in conjunction with NB Job Number B00645244.
B00645244-P7
Latest 60 of 188 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSKY CONSTRUCTION NY INC06/30/2026
DOB NOWPlumbingSigned-offYG SERVICES INC12/26/2025
DOB NOWMechanical SystemsPermit IssuedSKY CONSTRUCTION NY INC12/16/2025
DOB NOWGeneral ConstructionPermit IssuedSKY CONSTRUCTION NY INC12/09/2025
DOB NOWGeneral ConstructionSigned-offSKY CONSTRUCTION NY INC11/24/2025
DOB NOWConstruction FenceSigned-offSKY CONSTRUCTION NY INC11/21/2025
DOB NOWSidewalk ShedSigned-offCOLGATE ENTERPRISE CORP10/27/2025
DOB NOWSuspended ScaffoldSigned-offPRECISION HOIST & SCAFFOL08/12/2025
DOB NOWStandpipePermit IssuedSAFETY FIRE SPRINKLER CORP08/11/2025
DOB NOWStandpipePermit IssuedSAFETY FIRE SPRINKLER CORP08/11/2025
DOB NOWStandpipePermit IssuedSAFETY FIRE SPRINKLER CORP06/11/2025
DOB NOWStandpipePermit IssuedSAFETY FIRE SPRINKLER CORP03/06/2025
DOB NOWSupported ScaffoldSigned-offCOLGATE ENTERPRISE CORP01/21/2025
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP01/21/2025
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP01/21/2025
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP01/21/2025
DOB NOWSuspended ScaffoldSigned-offCOLGATE ENTERPRISE CORP01/06/2025
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP12/23/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP12/23/2024
DOB NOWConstruction FenceSigned-offSKY CONSTRUCTION NY INC12/11/2024
DOB NOWGeneral ConstructionPermit IssuedSKY CONSTRUCTION NY INC12/10/2024
DOB NOWMechanical SystemsPermit IssuedSKY CONSTRUCTION NY INC12/10/2024
DOB NOWSidewalk ShedSigned-offCOLGATE ENTERPRISE CORP11/21/2024
DOB NOWMechanical SystemsPermit IssuedSKY CONSTRUCTION NY INC08/08/2024
DOB NOWSprinklersPermit IssuedSAFETY FIRE SPRINKLER CORP05/17/2024
DOB NOWSprinklersPermit IssuedSAFETY FIRE SPRINKLER CORP05/06/2024
DOB NOWStandpipeSigned-offYG SERVICES INC05/06/2024
DOB NOWStructuralPermit IssuedSKY CONSTRUCTION NY INC03/15/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP02/09/2024
DOB NOWStandpipePermit IssuedSAFETY FIRE SPRINKLER CORP02/09/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP02/08/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP02/08/2024
DOB NOWSupported ScaffoldSigned-offCOLGATE ENTERPRISE CORP02/08/2024
DOB NOWStructuralPermit IssuedSKY CONSTRUCTION NY INC01/12/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP01/09/2024
DOB NOWProtection and Mechanical MethodsSigned-offCOLGATE ENTERPRISE CORP01/09/2024
DOB NOWGeneral ConstructionPermit IssuedSKY CONSTRUCTION NY INC12/29/2023
DOB NOWSidewalk ShedSigned-offCOLGATE ENTERPRISE CORP12/27/2023
DOB NOWFoundationPermit IssuedSKY CONSTRUCTION NY INC12/07/2023
DOB NOWConstruction FenceSigned-offSKY CONSTRUCTION NY INC12/06/2023
+ 4 more permits on file
2 projects · most recent 05/01/2026
Ventilation Systems Generators Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
05/01/2026Permit IssuedSKY CONSTRUCTION NY INCGenerators, Ventilation Systems
Ventilation
Greenheck SQ-95-VG 500 CFM · Exhaust Fan ×1
Generators
Gillette Generators SPVD-3500-3-2 350 kW · Generator ×1
02/05/2026Permit IssuedSKY CONSTRUCTION NY INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric PURY-EP216TSNU-A1 216,000 BTU · Vrf Outdoor ×18
PURY-EP312TSNU-A1 312,000 BTU · Vrf Outdoor ×18
PURY-EP168TNU-A1 168,000 BTU · Vrf Outdoor ×16
PURY-EP240TSNU-A1 240,000 BTU · Vrf Outdoor ×16
PURY-EP264TSNU-A1 264,000 BTU · Vrf Outdoor ×14
PURY-EP96TNU-A1 76,000 BTU · Vrf Outdoor ×12
PURY-EP120TNU-A1 120,000 BTU · Vrf Outdoor ×10
PURY-EP144TNU-A1 144,000 BTU · Vrf Outdoor ×8
PUHY-EP120TNU-A1 120,000 BTU · Vrf Outdoor ×6
PURY-EP72TNU-A1 72,000 BTU · Vrf Outdoor ×6
PURY-EP288TSNU-A1 288,000 BTU · Vrf Outdoor ×4
PUHY-EP144TNU-A1 144,000 BTU · Vrf Outdoor ×2
Heating
Mitsubishi Electric PURY-EP216TSNU-A1 243,000 BTU · Vrf Outdoor ×18
PURY-EP312TSNU-A1 350,000 BTU · Vrf Outdoor ×18
PURY-EP240TSNU-A1 270,000 BTU · Vrf Outdoor ×16
PURY-EP264TSNU-A1 295,000 BTU · Vrf Outdoor ×14
PURY-EP96TNU-A1 108,000 BTU · Vrf Outdoor ×12
PURY-EP120TNU-A1 135,000 BTU · Vrf Outdoor ×10
PURY-EP144TNU-A1 160,000 BTU · Vrf Outdoor ×8
PUHY-EP120TNU-A1 135,000 BTU · Vrf Outdoor ×6
PURY-EP72TNU-A1 80,000 BTU · Vrf Outdoor ×6
PURY-EP288TSNU-A1 323,000 BTU · Vrf Outdoor ×4
PUHY-EP144TNU-A1 160,000 BTU · Vrf Outdoor ×2
PUHY-EP192TNU-A1 215,000 BTU · Vrf Outdoor ×2
__Junk__ PURY-168TNU-A1 188,000 BTU · Heat Pump Outdoor ×16
Ventilation
Greenheck SQ-97-VG 160 CFM · Exhaust Fan ×30
SQ-98-VG 280 CFM · Exhaust Fan ×16
CSP-A700 570 CFM · Exhaust Fan ×10
SQ-160-VG 780 CFM · Exhaust Fan ×10
CSP-A3300 990 CFM · Exhaust Fan ×8
QEI-16 8,985 CFM · Exhaust Fan ×2
QEI-22 10,030 CFM · Exhaust Fan ×2
Rupp Air CFA 300RA 240 CFM · Exhaust Fan ×28
CFA 700RA 450 CFM · Exhaust Fan ×18
Markel E3323TD-RP 175 CFM · Electric Heater ×2
Nutone AEN110 50 CFM · Exhaust Fan ×2
1 project · most recent 02/05/2026
Sprinkler System
FiledStatusContractorScope
02/05/2026Permit IssuedSAFETY FIRE SPRINKLER CORSprinkler System
1 project · most recent 02/05/2026
Storm Water/Sanitary
FiledStatusContractorScope
02/05/2026Signed-offMPI PLUMBING CORPStorm, Water/Sanitary
5 projects · most recent 05/09/2026
General Wiring
FiledStatusContractorScope
05/09/2026CompleteJAM ELECTRICAL CORP—
07/02/2024Permit IssuedM.R. ELEC'L SERVICE LLCGeneral Wiring
01/08/2024CompleteNASH ELECTRIC SERVICES IN—
01/08/2024CompleteNASH ELECTRIC SERVICES IN—
12/18/2023CompleteNASH ELECTRIC SERVICES IN—
2 projects · most recent 02/05/2026
Concrete
FiledStatusContractorScope
02/05/2026Signed-offMPI PLUMBING CORPConcrete
01/02/2024——Concrete
1 project · most recent 08/13/2024
Scaffold
FiledStatusContractorScope
08/13/2024Signed-offCOLGATE ENTERPRISE CORPScaffold
▾Field Inspections (DOB CAP) — 24
DateTypeResultReport
07/30/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/04/2026Pass-Final General Construction Non-Directive 14PassView ↗
03/13/2026Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
03/13/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/13/2026Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
03/13/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
03/09/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/31/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/11/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
08/07/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/12/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/06/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/05/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
11/20/2024Pass-Final PL - More than 10 Requested FloorsPassView ↗
08/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/01/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/20/2024Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
03/20/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 85
DateRequirementInspectorRole
03/31/2026Mechanical SystemsSOORJBALLY HARILALLspecial
03/31/2026FinalSOORJBALLY HARILALLprogress
03/03/2026HVAC-R and service water heating equipmentSOORJBALLY HARILALLenergy_progress
03/03/2026HVAC-R and service water piping design and insulationSOORJBALLY HARILALLenergy_progress
03/03/2026Energy Code Compliance InspectionsSOORJBALLY HARILALLprogress
03/03/2026Standpipe SystemsSOORJBALLY HARILALLspecial
03/03/2026Sprinkler SystemsSOORJBALLY HARILALLspecial
03/03/2026Post-installed AnchorsSOORJBALLY HARILALLspecial
03/03/2026Fire-Resistant Penetrations and JointsSOORJBALLY HARILALLspecial
03/03/2026HVAC-R and service water heating system controlsSOORJBALLY HARILALLenergy_progress
03/03/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSOORJBALLY HARILALLspecial
03/03/2026Electrical motors and elevatorsSOORJBALLY HARILALLenergy_progress
03/03/2026Maintenance informationSOORJBALLY HARILALLenergy_progress
02/02/2026Fire-Resistant Penetrations and JointsSOORJBALLY HARILALLspecial
02/02/2026HVAC-R and service water heating system controlsSOORJBALLY HARILALLenergy_progress
02/02/2026HVAC-R and service water heating equipmentSOORJBALLY HARILALLenergy_progress
02/02/2026Maintenance informationSOORJBALLY HARILALLenergy_progress
02/02/2026Electrical motors and elevatorsSOORJBALLY HARILALLenergy_progress
02/02/2026HVAC-R and service water piping design and insulationSOORJBALLY HARILALLenergy_progress
02/02/2026Energy Code Compliance InspectionsSOORJBALLY HARILALLprogress
02/02/2026Standpipe SystemsSOORJBALLY HARILALLspecial
02/02/2026Sprinkler SystemsSOORJBALLY HARILALLspecial
02/02/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationSOORJBALLY HARILALLspecial
02/02/2026Post-installed AnchorsSOORJBALLY HARILALLspecial
12/09/2025Heating SystemsSOORJBALLY HARILALLspecial
Latest 25 of 85.
▾Documents — 161 on file (BIS + DOB NOW)
▸Plans & Drawings34
▸DOB NOWPlans/Sketch34
08/31/2026B00690563-I1Request digital key ↗
08/26/2026B00938589-P1Request digital key ↗
08/26/2026B00938589-I1Request digital key ↗
Showing 3 of 34 on file for this type
▸Applications & Permits3
▸BISBPP-5 - Authorization to the Department of Transportation1
04/11/2024340907442Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
04/11/2024340907442Open ↗
▸DOB NOWHPD - Permit Notice1
08/13/2026B00645244-I1Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00645244-I1Open ↗
08/13/2026B00645244-P5Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026B00645244-I1Open ↗
08/13/2026B00645244-P5Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026B00645244-I1Open ↗
▸Seals & Professional Certifications72
▸DOB NOWDPL-1: Design Professional Seal & Signature35
08/31/2026B00690563-I1Open ↗
08/26/2026B00938589-P1Open ↗
08/26/2026B00938589-I1Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWProgress Inspector Seal & Signature20
09/23/2026B00645244-S6Open ↗
09/23/2026B00645244-S6Open ↗
09/01/2026B01293887-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/23/2026B00645244-S6Open ↗
08/29/2026B00984783-P1Open ↗
08/27/2026B00645244-S4Open ↗
Showing 3 of 15 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/11/2024340907442Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/11/2024340907442Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWStandpipe Alarms Drawings1
08/14/2026B00645244-I1—
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
04/11/2024340907442Open ↗
04/11/2024340907442Open ↗
▸BISBPP: STREET TREES SITE PLAN1
04/11/2024340907442Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00645244-I1Open ↗
▸Environmental & Asbestos21
▸DOB NOWOER: Notice to Proceed16
08/26/2026B00645244-S5Open ↗
08/13/2026B00645244-P5Open ↗
08/13/2026B01293887-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWOER: Notice of Satisfaction4
08/26/2026B00645244-S3Open ↗
08/26/2026B00645244-S3Open ↗
08/20/2026B01293887-I1Open ↗
Showing 3 of 4 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
04/11/2024340907442Open ↗
▸Inspections & Test Reports1
▸DOB NOWTR5 Test Report1
08/14/2026B00645244-S1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISNYS DEC TIDAL WETLANDS APPROVAL1
04/11/2024340907442Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
04/11/2024340907442Open ↗
04/11/2024340907442Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
04/11/2024340907442Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/11/2024340907442Open ↗
▸Other Documents15
▸BISBPP - SUPPORTING DOCUMENTATION3
04/11/2024340907442Open ↗
04/11/2024340907442Open ↗
04/11/2024340907442Open ↗
▸DOB NOWLowest Floor Elevation Plan2
08/14/2026B00645244-S1Open ↗
08/14/2026B00645244-S2Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00645244-S1Open ↗
08/13/2026B00645244-S2Open ↗
▸DOB NOWFlood Plan Emergency Temporary Flood Shields2
08/26/2026B00645244-P5Open ↗
08/14/2026B00645244-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026B00645244-P5Open ↗
08/13/2026B00645244-I1Open ↗
▸DOB NOWCalculations1
08/13/2026B01153541-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026B01153541-I1Open ↗
▸DOB NOWFinal Survey1
08/14/2026B00645244-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00645244-I1Open ↗