← Back
QUEENS
399 A BAYSIDE AVENUE
QUEENS · BIN 4625652
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction10p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BREEZY POINT COOPERATIVE, INC.1107/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VALENTINO POMPEO ARCHITECT, P.C.306/09/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SIMPLY STRONG CONSTRUCTGeneral Contractor404/09/2026
JOSEPH O'GRADY P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495203/05/2025
Building Lifecycle
All (72)Filed (3)Permit Issued (3)Objection (36)Special Inspection (30)
03/20/2026
Permit issued — Plumbing
Q01168245-S1-PL
02/20/2026
Objection resolved — Addressed
02/20/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/09/2026
Objection resolved — Addressed
11/17/2025
Permit issued — General Construction
Q01168245-I1-GC-CX
11/06/2025
Objection raised — Fire_Protection
11/06/2025
Objection raised — Fire_Protection
11/06/2025
Objection raised — Plumbing
11/06/2025
Objection raised — Fire_Protection
10/16/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
09/30/2025
Permit issued — Construction Fence
Q01168245-S2-FN
09/29/2025
Objection resolved — Addressed
09/23/2025
Objection resolved — Addressed
09/19/2025
Objection raised — Zoning
09/05/2025
Objection resolved — Addressed
08/14/2025
Objection resolved — Addressed
08/05/2025
Objection raised — Other
06/30/2025
Special inspection requirement — Sprinkler Systems
Rajasekhar Sakhamuri
06/30/2025
Special inspection requirement — Maintenance information
Rajasekhar Sakhamuri
06/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
06/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
06/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Rajasekhar Sakhamuri
06/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
06/16/2025
Objection raised — Other
06/16/2025
Objection resolved — Addressed
06/16/2025
Objection resolved — Addressed
06/11/2025
Objection raised — Other
06/11/2025
Objection resolved — Addressed
06/09/2025
Filed — New Building
APPLICATION FILED FOR CONSTRUCTION OF A NEW 2 STORY, 1 FAMILY DWELLING. ALL WORK IS PER PLANS FILED HEREWITH.
Q01168245-S2
06/03/2025
Objection resolved — Addressed
06/03/2025
Objection resolved — Addressed
06/03/2025
Special inspection requirement — Electric vehicle service equipment requirements
Rajasekhar Sakhamuri
05/27/2025
Objection raised — Energy
05/27/2025
Objection raised — Structural
05/27/2025
Objection raised — Inspections
05/16/2025
Objection resolved — Addressed
03/28/2025
Objection raised — Zoning
03/28/2025
Objection raised — Zoning
03/28/2025
Objection raised — Scope
03/28/2025
Objection raised — Scope
03/14/2025
Objection raised — Plumbing
03/14/2025
Objection raised — Energy
03/06/2025
Objection raised — Scope
03/05/2025
Filed — New Building
APPLICATION FILED FOR CONSTRUCTION OF A NEW 2 STORY, 1 FAMILY DWELLING. ALL WORK IS PER PLANS FILED HEREWITH.
Q01168245-S1
03/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
02/21/2025
Filed — New Building
APPLICATION FILED FOR CONSTRUCTION OF A NEW 2 STORY, 1 FAMILY DWELLING. ALL WORK IS PER PLANS FILED HEREWITH.
Q01168245-I1
02/21/2025
Special inspection requirement — Permanent certificate
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Air barrier — testing
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Insulation placement and R values
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Ventilation and air distribution system
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Interior lighting power
Rajasekhar Sakhamuri
02/21/2025
Special inspection requirement — Metering
Rajasekhar Sakhamuri
02/20/2025
Special inspection requirement — Fenestration air leakage
Rajasekhar Sakhamuri
02/20/2025
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
02/20/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Rajasekhar Sakhamuri
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJOSEPH O'GRADY P & H INC03/20/2026
DOB NOWGeneral ConstructionPermit IssuedSIMPLY STRONG CONSTRUCT11/17/2025
DOB NOWConstruction FencePermit IssuedSIMPLY STRONG CONSTRUCT09/30/2025
1 project · most recent 06/09/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/09/2025Permit IssuedSIMPLY STRONG CONSTRUCTAir Conditioning Systems
Cooling
Fujitsu UPDATE WHEN UNIT CUT SHEET IS SHARED 60,000 BTU · Condensing Unit ×1
1 project · most recent 06/09/2025
FiledStatusContractorScope
06/09/2025——23 heads
1 project · most recent 06/09/2025
Water/Sanitary
FiledStatusContractorScope
06/09/2025Permit IssuedJOSEPH O'GRADY P & H INCWater/Sanitary
1 project · most recent 06/04/2026
General Wiring
FiledStatusContractorScope
06/04/2026Permit IssuedPAPPAS & FODERA ELECT'LGeneral Wiring
1 project · most recent 06/09/2025
FiledStatusContractorScope
06/09/2025Permit IssuedJOSEPH O'GRADY P & H INC1 scope_items
1 project · most recent 06/09/2025
Fence
FiledStatusContractorScope
06/09/2025Permit IssuedJOSEPH O'GRADY P & H INCFence
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
06/30/2025Sprinkler SystemsRajasekhar Sakhamurispecial
06/30/2025Maintenance informationRajasekhar Sakhamurienergy_progress
06/30/2025Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
06/30/2025HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
06/30/2025HVAC-R and service water heating system controlsRajasekhar Sakhamurienergy_progress
06/30/2025HVAC-R and service water heating equipmentRajasekhar Sakhamurienergy_progress
06/03/2025Electric vehicle service equipment requirementsRajasekhar Sakhamurienergy_progress
03/04/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
02/21/2025Permanent certificateRajasekhar Sakhamurienergy_progress
02/21/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
02/21/2025Air barrier — testing Rajasekhar Sakhamurienergy_progress
02/21/2025Insulation placement and R valuesRajasekhar Sakhamurienergy_progress
02/21/2025Ventilation and air distribution systemRajasekhar Sakhamurienergy_progress
02/21/2025Interior lighting powerRajasekhar Sakhamurienergy_progress
02/21/2025MeteringRajasekhar Sakhamurienergy_progress
02/20/2025Fenestration air leakageRajasekhar Sakhamurienergy_progress
02/20/2025Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
02/20/2025Fenestration and door U-factor and product ratingsRajasekhar Sakhamurienergy_progress
02/20/2025Maintenance informationRajasekhar Sakhamurienergy_progress
02/20/2025Subgrade InspectionsRajasekhar Sakhamurispecial
02/20/2025HVAC-R and service water heating system controlsRajasekhar Sakhamurienergy_progress
02/20/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)Rajasekhar Sakhamurispecial
02/20/2025Fenestration areasRajasekhar Sakhamurienergy_progress
02/20/2025HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
02/20/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
Latest 25 of 33.
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026Q01168245-I1Request digital key ↗
08/20/2026Q01168245-S2Request digital key ↗
08/20/2026Q01168245-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01168245-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01168245-I1Open ↗
▸Seals & Professional Certifications36
▸DOB NOWProgress Inspector Seal & Signature25
08/29/2026Q01168245-S1Open ↗
08/29/2026Q01168245-S1Open ↗
08/29/2026Q01168245-S1Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/29/2026Q01168245-S1Open ↗
08/29/2026Q01168245-S1Open ↗
08/25/2026Q01168245-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026Q01168245-I1Open ↗
08/20/2026Q01168245-S1Open ↗
08/20/2026Q01168245-S2Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01168245-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01168245-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01168245-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01168245-I1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01168245-I1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification1
08/20/2026Q01168245-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01168245-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01168245-I1Open ↗