1998Year Built
2Stories
B2Building Class
R3AZoning
2,400 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family frame · 4,836 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GLM ASSOCIATES208/29/2026
TO THE OWNER OF 4 MAINDEN103/22/2026
A T P DEVELOPMENT103/21/2026
TOWER ESTATES603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC105/04/2026
GREEN RIVER ENVIRONMENTAL ENGINEERI103/10/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NY State Solar LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYSS LLCGeneral Contractor106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/04/2026
GREEN RIVER ENVIRONMENTAL7841103/10/2025
Building Lifecycle
All (10)Filed (2)Permit Issued (2)Violation (2)Special Inspection (4)
05/12/2026
Permit issued — Solar
S01397012-I1-SL
05/04/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
S01397012-I1
05/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/04/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/04/2026
Special inspection requirement — Final
TOM PETERSEN
05/04/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/31/2026
Permit issued — Solar
S01192437-I1-SL
03/10/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
S01192437-I1
02/04/2004
Violation issued (ECB, open)
Construction
12/31/1996
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedTOM PETERSEN ARCHITECT, LLC05/12/2026
DOB NOWSolarPermit IssuedNYSS LLC03/31/2026
BISEQISSUEDTOWER ESTATES INC02/05/2001
BISEQISSUEDTOWER ESTATES INC01/21/2000
BIS—ISSUEDTOWER ESTATES, INC01/25/1999
BISEQISSUEDTOWER ESTATES INC01/20/1999
BISPLISSUEDORMONDE MCCARTY PLBG & HEATING02/10/1998
BIS—ISSUEDTOWER ESTATES, INC01/13/1998
BIS—ISSUEDA.T.P. DEVELOPMENT CORP.04/17/1996
2 projects · most recent 05/04/2026
FiledStatusContractorScope
05/04/2026Permit IssuedVENTURE HOME SOLAR LLC—
03/10/2025CancelledNY SOLAR ELECTRICAL LLC—
2 projects · most recent 05/04/2026
FiledStatusContractorScope
05/04/2026Permit IssuedTOM PETERSEN ARCHITECT, LLC28 panels, 12.32 kw, 2,400 roof_area_sqft
03/10/2025Permit IssuedNYSS LLC25 panels, 10.75 kw, 1,514 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
05/04/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/04/2026Energy Code Compliance InspectionsTOM PETERSENprogress
05/04/2026FinalTOM PETERSENprogress
05/04/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026S01192437-I1Request digital key ↗
08/16/2026S01397012-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026S01192437-I1Open ↗
08/16/2026S01397012-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026S01397012-I1Open ↗
08/29/2026S01397012-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026S01397012-I1Open ↗