Two family brick
40 BAY 7 STREET
BROOKLYN · Bath Beach · BIN 3165997
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R4Zoning
2,160 sfGross Floor Area
2Units
Two family brick · Owner of record: JW 40 BAY INC. · 2,320 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 23p · 2 filings · 10 docs
Floor 1
Cellar4p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2025$1.4M—Private party → JW 40 BAY INC.$660/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FARHAD BASSIRI-TEHRANI407/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor104/09/2026
S & L PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394207/30/2025
Building Lifecycle
All (16)Filed (4)Permit Issued (2)Signed Off (2)Inspection (5)Special Inspection (3)
11/14/2025
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237589-I1
10/22/2025
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237586-I1
10/21/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/24/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
07/31/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
07/31/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
07/30/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237586-P1
07/30/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237589-P1
07/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/08/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/12/2025
Permit issued — Plumbing
B01237589-I1-PL
06/10/2025
Permit issued — General Construction
B01237586-I1-GC
06/06/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237589-I1
06/06/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01237586-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offS & L PLUMBING INC06/12/2025
DOB NOWGeneral ConstructionSigned-offKALE CONSTRUCTION INC06/10/2025
2 projects · most recent 06/11/2025
General Wiring
FiledStatusContractorScope
06/11/2025CompleteA.C. MORGAN ELECTRICGeneral Wiring
11/27/2019CompleteL.J.F. & SONS ELECL CONTS3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/21/2025Pass-Final General Construction Non-Directive 14PassView ↗
09/24/2025Fail-Final General Construction Non-Directive 14FailView ↗
08/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/08/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
07/31/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
07/31/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
07/31/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026B01237586-P1Request digital key ↗
08/21/2026B01237586-I1Request digital key ↗
08/21/2026B01237589-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026B01237586-I1Open ↗
08/21/2026B01237589-I1Open ↗
08/13/2026B01237586-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026B01237586-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026B01237586-I1Open ↗