1 Active Violation 0 unresolved · 1 paperwork only ▸
Elevator apt, semi-fireproof with stores · Owner of record: 40 West 167th Street · 4,661 sf lot · 5.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofThe Olympic TowerUnder Construction46p · 2 filings · 20 docs
Bulkhead2p · 1 filing · 20 docs
Floor 10The Olympic TowerUnder Construction1p · 1 filing · 11 docs
Floor 9
Floor 8
Floor 713p · 1 filing · 20 docs
Floor 613p · 1 filing · 20 docs
Floor 513p · 1 filing · 20 docs
Floor 413p · 1 filing · 20 docs
Floor 367p · 1 filing · 20 docs
Floor 213p · 1 filing · 20 docs
Floor 183p · 1 filing · 20 docs
Cellar13p · 1 filing · 20 docs
BasementThe Olympic TowerUnder Construction1p · 1 filing · 11 docs
Site & exteriorTemporary pipe scaffold installation12p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SKY Home Group3307/08/2026
Blue Home Holding103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/02/2019$130K—Private party → BLUE HOME HOLDING INC.— not available
04/21/2017$151K—Private party → NYCTL 1998-2 TRUST— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Sharon Associates705/07/2026
Gerald Caliendo Architects404/10/2026
RMM Design Studio203/23/2026
Ashraf407/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Gerald J. Caliendo R.A1203/21/2026
Danico Services803/21/2026
Ebc Consulting203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Impact BuildersGeneral Contractor2307/08/2026
Impact BuildersScaffold907/08/2026
Lakhi General ContractorScaffold304/09/2026
Record GroupGeneral Contractor207/08/2026
Doug's Plumbing & Heating Service CoFire Protection207/08/2026
Plumbing-It MechanicalPlumbing207/08/2026
First Class Management CoGeneral Contractor104/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
World Design Architecture9323605/07/2026
IP Concrete Testing and I6252204/10/2026
HRF Services5616108/05/2025
AA Building & Inspection1519104/01/2022
Building Lifecycle
All (137)Filed (18)Permit Issued (27)Signed Off (10)Violation (15)Inspection (13)Objection (21)Special Inspection (30)Tax Incentive (3)
10/01/2029
421-a(16) construction completed
10/15/2026
Signed off — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-S6
09/29/2026
Signed off — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-S7
09/29/2026
Signed off — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-S3
08/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/12/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/11/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/09/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
06/09/2026
Special inspection requirement — Mechanical Systems
Younes Abouyaala
06/09/2026
Special inspection requirement — Final
NAVEEN KUMAR
06/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
JEFFREY BELL
06/09/2026
Special inspection requirement — Maintenance information
JEFFREY BELL
06/09/2026
Special inspection requirement — Duct leakage testing, insulation and design
JEFFREY BELL
06/09/2026
Special inspection requirement — Electrical motors and elevators
JEFFREY BELL
06/09/2026
Special inspection requirement — Metering
JEFFREY BELL
06/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
JEFFREY BELL
06/09/2026
Special inspection requirement — Shutoff dampers
Younes Abouyaala
06/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JEFFREY BELL
06/08/2026
Signed off — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-S5
06/08/2026
Signed off — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-S2
06/03/2026
Special inspection requirement — Electrical motors and elevators
JEFFREY BELL
06/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
06/03/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
William Alicea
06/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
06/03/2026
Special inspection requirement — Sprayed fire-resistant materials
William Alicea
06/03/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
INDARDEO PARBHUNATH
06/03/2026
Special inspection requirement — Fire-Resistance Rated Construction
JEFFREY BELL
06/03/2026
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
06/03/2026
Special inspection requirement — Fenestration air leakage
JEFFREY BELL
06/03/2026
Special inspection requirement — Vestibules
JEFFREY BELL
06/03/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
JEFFREY BELL
06/03/2026
Special inspection requirement — Insulation placement and R values
JEFFREY BELL
06/03/2026
Special inspection requirement — Maintenance information
JEFFREY BELL
06/03/2026
Special inspection requirement — Interior lighting power
JEFFREY BELL
06/03/2026
Special inspection requirement — Lighting controls
JEFFREY BELL
06/03/2026
Special inspection requirement — Exterior lighting power
JEFFREY BELL
06/03/2026
Special inspection requirement — Fenestration areas
JEFFREY BELL
06/03/2026
Special inspection requirement — Protection of exposed foundation insulation
JEFFREY BELL
06/03/2026
Special inspection requirement — Metering
JEFFREY BELL
05/08/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/07/2026
Filed — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-P5
04/23/2026
Permit issued — General Construction
X00655372-I1-GC
04/20/2026
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
04/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/15/2026
Permit issued — Plumbing
X00655372-S3-EW-SP
04/15/2026
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
04/15/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/10/2026
Filed — New Building
FO & EA WORK FOR A SEVEN (7)-STORY, MIXED-USE NEW BUILDING WITH (24) RESIDENTIAL DWELLING UNITS, CELLAR PARKING FOR (8) EIGHT CARS FOR RESIDENTIAL USE, & COMMUNITY FACILITY ON THE GROUND FLOOR.
X00655372-P4
04/09/2026
Objection raised — Other
03/23/2026
Filed — Alteration
X01304281-P2
03/11/2026
Permit issued — Curb Cut
X00655372-S6-CC
03/11/2026
Permit issued — Mechanical Systems
X00655372-S7-MS
03/05/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD FOR NEW BUILDING AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE 2022 NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.SIDEWALK SHED FILED ON A SEPARATE APPLICATION.
X01216156-I1
03/05/2026
Signed off — Alteration
X01161083-I1
01/23/2026
Permit issued — Construction Fence
X00655372-S5-FN
01/20/2026
Permit issued — Solar
X01304281-I1-SL
01/19/2026
Signed off — Alteration
X01266352-I1
01/02/2026
Permit issued — Plumbing
X00655372-S3-PL
12/16/2025
Filed — Alteration
X01304281-I1
11/07/2025
Permit issued — General Construction
X00655372-I1-GC
Latest 60 of 137 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRecord Group04/23/2026
DOB NOWSprinklersSigned-offDoug's Plumbing & Heating Service Co04/15/2026
DOB NOWCurb CutSigned-offImpact Builders03/11/2026
DOB NOWMechanical SystemsSigned-offImpact Builders03/11/2026
DOB NOWConstruction FenceSigned-offImpact Builders01/23/2026
DOB NOWSolarPermit IssuedImpact Builders01/20/2026
DOB NOWPlumbingSigned-offJVR Plumbing and Heating01/02/2026
DOB NOWGeneral ConstructionPermit IssuedRecord Group11/07/2025
DOB NOWSuspended ScaffoldSigned-offSha Home Improvement10/01/2025
DOB NOWStructuralSigned-offImpact Builders09/18/2025
DOB NOWSuspended ScaffoldSigned-offSha Home Improvement08/19/2025
DOB NOWSupported ScaffoldSigned-offLakhi General Contractor05/01/2025
DOB NOWSprinklersSigned-offDoug's Plumbing & Heating Service Co03/10/2025
DOB NOWConstruction FenceSigned-offImpact Builders02/07/2025
DOB NOWStructuralSigned-offImpact Builders01/16/2025
DOB NOWSidewalk ShedSigned-offLakhi General Contractor01/09/2025
DOB NOWGeneral ConstructionPermit IssuedFirst Class Management Co11/01/2024
DOB NOWPlumbingSigned-offJVR Plumbing and Heating09/25/2024
DOB NOWSupport of ExcavationSigned-offImpact Builders02/12/2024
DOB NOWConstruction FenceSigned-offImpact Builders02/12/2024
DOB NOWFoundationSigned-offImpact Builders02/12/2024
DOB NOWFoundationSigned-offImpact Builders05/24/2023
DOB NOWSupport of ExcavationSigned-offImpact Builders05/24/2023
DOB NOWConstruction FenceSigned-offImpact Builders05/24/2023
DOB NOWEarth WorkSigned-offImpact Builders06/07/2022
DOB NOWSupport of ExcavationSigned-offImpact Builders06/07/2022
DOB NOWConstruction FenceSigned-offImpact Builders05/23/2022
1 project · most recent 05/07/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/07/2026Permit IssuedRecord GroupHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUMY-P36NKMU3 42,000 BTU · Vrf Outdoor ×64
PUMY-P48NKMU3 48,000 BTU · Vrf Outdoor ×32
Ventilation
Greenheck G-090-VG 150 CFM · Exhaust Fan ×16
1 project · most recent 05/07/2026
Sprinkler System
FiledStatusContractorScope
05/07/2026Signed-offDoug's Plumbing & Heating Service CoSprinkler System
1 project · most recent 05/07/2026
Storm Water/Sanitary
FiledStatusContractorScope
05/07/2026Signed-offPlumbing-It MechanicalStorm, Water/Sanitary
5 projects · most recent 09/08/2026
General Wiring
FiledStatusContractorScope
09/08/2026CompleteAL-Lectric Elect'l ContractingGeneral Wiring
08/04/2025CompleteVillage Electl Contractors—
03/10/2025Permit IssuedPower Direct Electric—
02/20/2025Permit IssuedK.N.C. Electric—
02/20/2025CompleteAL-Lectric Elect'l ContractingGeneral Wiring
1 project · most recent 05/07/2026
FiledStatusContractorScope
05/07/2026Permit IssuedRecord Group3 scope_items
1 project · most recent 05/07/2026
Fence
FiledStatusContractorScope
05/07/2026Permit IssuedRecord GroupFence
1 project · most recent 05/07/2026
Earthwork
FiledStatusContractorScope
05/07/2026Permit IssuedRecord GroupEarthwork
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
08/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/12/2026Pass-Final CND-Occupancy InspectionPassView ↗
06/11/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/08/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/20/2026Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
04/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/15/2026Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
04/15/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/04/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/14/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/13/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/15/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 57
DateRequirementInspectorRole
06/09/2026Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
06/09/2026Mechanical SystemsYounes Abouyaalaspecial
06/09/2026FinalNAVEEN KUMARprogress
06/09/2026HVAC-R and service water heating equipmentJEFFREY BELLenergy_progress
06/09/2026Maintenance informationJEFFREY BELLenergy_progress
06/09/2026Duct leakage testing, insulation and designJEFFREY BELLenergy_progress
06/09/2026Electrical motors and elevatorsJEFFREY BELLenergy_progress
06/09/2026MeteringJEFFREY BELLenergy_progress
06/09/2026HVAC-R and service water heating system controlsJEFFREY BELLenergy_progress
06/09/2026Shutoff dampersYounes Abouyaalaenergy_progress
06/09/2026HVAC-R and service water piping design and insulationJEFFREY BELLenergy_progress
06/03/2026Electrical motors and elevatorsJEFFREY BELLenergy_progress
06/03/2026Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
06/03/2026Exterior Insulation and Finish Systems (EIFS)William Aliceaspecial
06/03/2026Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
06/03/2026Sprayed fire-resistant materialsWilliam Aliceaspecial
06/03/2026Wall Panels, Curtain Walls, and VeneersINDARDEO PARBHUNATHspecial
06/03/2026Fire-Resistance Rated ConstructionJEFFREY BELLprogress
06/03/2026Energy Code Compliance InspectionsJEFFREY BELLprogress
06/03/2026Fenestration air leakageJEFFREY BELLenergy_progress
06/03/2026VestibulesJEFFREY BELLenergy_progress
06/03/2026Fenestration and door U-factor and product ratingsJEFFREY BELLenergy_progress
06/03/2026Insulation placement and R valuesJEFFREY BELLenergy_progress
06/03/2026Maintenance informationJEFFREY BELLenergy_progress
06/03/2026Interior lighting powerJEFFREY BELLenergy_progress
Latest 25 of 57.
▾Documents — 107 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch18
08/19/2026X01216156-I1Request digital key ↗
08/19/2026X01216156-P1Request digital key ↗
08/19/2026X01161083-I1Request digital key ↗
Showing 3 of 18 on file for this type
▸Applications & Permits1
▸BISBPP-5 - Authorization to the Department of Transportation1
03/30/2022240316378Open ↗
▸Zoning, Tax Lot & Property Records21
▸DOB NOWRestrictive Declaration/Easement 15
08/17/2026X00655372-S7Open ↗
08/17/2026X00655372-S2Open ↗
08/17/2026X00655372-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWRestrictive Declaration/Easement 25
08/17/2026X00655372-S7Open ↗
08/17/2026X00655372-S2Open ↗
08/17/2026X00655372-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWRestrictive Declaration/Easement 34
08/17/2026X00655372-S7Open ↗
08/17/2026X00655372-I1Open ↗
08/17/2026X00655372-P4Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram3
08/17/2026X00655372-I1Open ↗
08/17/2026X00655372-P4Open ↗
08/13/2026X00655372-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/17/2026X00655372-P4Open ↗
08/13/2026X00655372-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
03/30/2022240316378Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026X00655372-I1Open ↗
▸Seals & Professional Certifications43
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/19/2026X01216156-P1Open ↗
08/19/2026X01216156-I1Open ↗
08/19/2026X01161083-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature16
09/02/2026X00655372-P1Open ↗
09/02/2026X00655372-S1Open ↗
09/01/2026X01304281-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/03/2026X00655372-S3Open ↗
09/01/2026X01304281-I1Open ↗
09/01/2026X00655372-P5Open ↗
Showing 3 of 9 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/28/2022240316378Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026X00655372-I1Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist2
08/17/2026X00655372-I1Open ↗
08/17/2026X00655372-P4Open ↗
▸BISBPP: STREET TREES SITE PLAN1
03/30/2022240316378Open ↗
▸BISSTREET TREE CHECKLIST1
03/30/2022240316378Open ↗
▸DOB NOWStreet Trees Site Plan1
08/17/2026X00655372-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/17/2026X00655372-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00655372-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/17/2026X00655372-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/30/2022240316378Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
03/28/2022240316378Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
03/30/2022240316378Open ↗
▸Other Documents12
▸DOB NOWAdjoining Owners Notification2
08/13/2026X00655372-S1Open ↗
08/13/2026X00655372-S4Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026X00655372-I1Open ↗
08/17/2026X00655372-P4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026X00655372-P4Open ↗
08/13/2026X00655372-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/17/2026X00655372-I1Open ↗
08/17/2026X00655372-P4Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026X01266352-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026X00655372-I1Open ↗
▸DOB NOWCalculations1
08/13/2026X01266352-I1Open ↗
▸DOB NOWFinal Survey1
08/17/2026X00655372-I1Open ↗