← Back
BuildNYC
Predominantly retail with other uses
400 BAY STREET
STATEN ISLAND · BIN 5106825
💬 Discuss this project
1931Year Built
3Stories
K4Building Class
R6Zoning
6,400 sfGross Floor Area
6Units
0 Active ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: Dema Properties · 7,062 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 1Island Rotisserie Chicken5p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Island Rotisserie Chicken1607/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Stewart301/17/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Done Right Kitchen ExhausGeneral Contractor303/21/2026
Paul Traktman Lic PLBRPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Stewart Engineering Services2506301/17/2020
Building Lifecycle
All (15)Filed (3)Permit Issued (3)Violation (1)Special Inspection (8)
05/29/2024
Violation issued (ECB, closed)
Construction
02/18/2020
Permit issued — Plumbing
S00210243-I1-PL
01/17/2020
Filed — Alteration
Plumbing for restaurant
S00210243-P1
01/17/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
EGAR STEWART
01/17/2020
Special inspection requirement — Electrical energy consumption
EGAR STEWART
01/16/2020
Special inspection requirement — Electrical energy consumption
EGAR STEWART
01/16/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
EGAR STEWART
11/22/2019
Permit issued — Mechanical Systems
S00246360-I1-MS
11/12/2019
Permit issued — Plumbing
S00210243-I1-PL
10/17/2019
Filed — Alteration
Installation of commercial kitchen hood and exhaust system
S00246360-I1
10/15/2019
Special inspection requirement — Energy Code Compliance Inspections
EGAR STEWART
10/15/2019
Special inspection requirement — Fire-Resistance Rated Construction
EGAR STEWART
10/15/2019
Special inspection requirement — Mechanical Systems
EGAR STEWART
10/15/2019
Special inspection requirement — Final
EGAR STEWART
08/28/2019
Filed — Alteration
Plumbing for restaurant
S00210243-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPaul Traktman Lic PLBR02/18/2020
DOB NOWMechanical SystemsPermit IssuedDone Right Kitchen Exhaus11/22/2019
DOB NOWPlumbingSigned-offPaul Traktman Lic PLBR11/12/2019
BISOTISSUEDCorporate Construction & Project11/18/2019
BISOTISSUEDL J & A Construction11/13/2019
1 project · most recent 10/17/2019
Others
FiledStatusContractorScopeMake / Model / Capacity
10/17/2019Permit IssuedDone Right Kitchen ExhausOthers
Other
Dayton 5DVR0 3,445 CFM · Kitchen Exhaust ×1
1 project · most recent 01/17/2020
Gas Water/Sanitary
FiledStatusContractorScope
01/17/2020Signed-offPaul Traktman Lic PLBRGas, Water/Sanitary
2 projects · most recent 12/30/2024
General Wiring
FiledStatusContractorScope
12/30/2024CompleteRidge ElectricGeneral Wiring
02/01/2020CompleteLotus ElectricGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/17/2020Fire-Resistant Penetrations and JointsEGAR STEWARTspecial
01/17/2020Electrical energy consumptionEGAR STEWARTenergy_progress
01/16/2020Electrical energy consumptionEGAR STEWARTenergy_progress
01/16/2020Fire-Resistant Penetrations and JointsEGAR STEWARTspecial
10/15/2019Energy Code Compliance InspectionsEGAR STEWARTprogress
10/15/2019Fire-Resistance Rated ConstructionEGAR STEWARTprogress
10/15/2019Mechanical SystemsEGAR STEWARTspecial
10/15/2019FinalEGAR STEWARTprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Island Rotisserie ChickenRestaurant / Food ServiceFloor 1
Project S00246360 Alteration · Permit Entire · 10/17/2019
Project S00210243 Alteration · Permit Entire · 08/28/2019
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
08/26/2026S00210243-I1Request digital key ↗
08/15/2026S00210243-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/26/2026S00246360-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
10/01/2019540169253Open ↗
08/29/2019520390087Open ↗
▸BISWORK PERMIT APPLICATION2
11/19/2019540169253Open ↗
11/13/2019540169253Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISFLOOD ZONE DESIGN CERTIFICATION1
10/01/2019540169253Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature5
08/25/2026S00210243-P1Open ↗
08/24/2026S00246360-I1Open ↗
08/24/2026S00246360-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/25/2026S00210243-P1Open ↗
08/24/2026S00246360-I1Open ↗
08/24/2026S00210243-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026S00246360-I1Open ↗
08/13/2026S00210243-I1Open ↗
08/13/2026S00210243-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/01/2019540169253Open ↗
08/29/2019520390087Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/01/2019540169253Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/29/2019520390087Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/01/2019540169253Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/29/2019520390087Open ↗
▸Safety & Tenant Protection5
▸DOB NOWTenant Protection Plan3
08/13/2026S00210243-I1Open ↗
08/13/2026S00246360-I1Open ↗
08/13/2026S00210243-P1Open ↗
▸BISSTREET TREE CHECKLIST1
08/29/2019520390087Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
10/01/2019540169253Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026S00246360-I1Open ↗
08/13/2026S00210243-I1Open ↗
08/13/2026S00210243-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/01/2019540169253Open ↗
08/29/2019520390087Open ↗
▸DOB NOWOER: Notice to Proceed2
08/13/2026S00210243-I1Open ↗
08/13/2026S00210243-P1Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
10/01/2019540169253Open ↗
▸DOB NOWOER: Notice of Satisfaction1
08/13/2026S00210243-I1Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/13/2019540169253Open ↗
10/01/2019540169253Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/29/2019520390087Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/01/2019540169253Open ↗
▸BISNYCECC ANALYSIS1
10/01/2019540169253Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/13/2019540169253Open ↗
10/01/2019540169253Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
08/29/2019520390087Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/19/2019540169253Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/01/2019540169253Open ↗
08/29/2019520390087Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION3
11/13/2019540169253Open ↗
09/09/2019520390087Open ↗
09/09/2019520390087Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/01/2019540169253Open ↗
▸BISEFILING COVER SHEET1
08/29/2019520390087Open ↗