DOB05/08/2025FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER NOTE MULTIPLE BROKEN CRACKED WINDOWS, DAMAGED BALCONIES OBSERVED DAMAGE CORNICE AND DAMAGED STONE AND WATER TABLE MULTIPLE LOCATIONS. REMEDY: REPAIR AND/OR REPLACE
DOB02/16/2024CYCLE 9C UNSAFE REPORT FILED
DOB08/09/2023EMERGENCY WORK.FACADE IN STATE OF DISREPAIR,FISP REPORT#802931-8C FILED FACADE UNSAFE W/INITIAL FILING DATE OF 9/15/17 REQ'D RESTORATION OF FACDE W/IMMED RPRS TO UNSAFE CNDITIONS&RPRS TO SWARMP CNDITIONS BY 9/11/19.ADR FOR JOB312320 TO IMMED EVAL ALL EXTERIOR WALLS&FILE PAA W/ ANY REQ'D CHANGES TO APPRVD FACADE RPR DRWNGS.IMMED COMMENCE FACADE RP
DOB08/09/2023EMERGENCY WORK.BSMNT FL FRAMNG&SLABS&CELLAR LVL COLUMNS IN A STATE OF DISREPAIR.UNDERSIDE OF SLABS HAVE SPALLS W/SEVERELYDTERIORATD MESH EXPOSD IN MULT LOCATIONS.CRCKD&SPALLD CONC ENCASEMENT.IMMED INSTALL TEMP SHORNG&BRACNG OR STRCTRL COLUMN REINFORCMNT@DRECTION OF NYS PE SKETCHES&INSPECTD BY REG SPEC
DOB07/31/2023EMERGENCY WORK.BSMNT FL FRAMNG&SLABS&CELLAR LVL COLUMNS IN A STATE OF DISREPAIR.UNDERSIDE OF SLABS HAVE SPALLS W/SEVERELY DETERIORATD MESH EXPOSD IN MULT LOCATIONS.CRCKD&SPALLD CONC BASEMENT.NYS PE STRCTRL ENG TO IMMED EVAL ENT STRUCTURE&SURVEY FOR OVERHEAD HAZARDS@CELLAR&BSMNT LVLS.IMMED PROBE BSMNT FL
DOB07/31/2023EMERG WRK-CITY OWND BLD-MENS SHELTER-BSMNT&CELLAR LEVELS INDISRPR STATE.UNDERSID SLABS-SPALLS W/SEVERELY DETRTD MESH EXPOSD MULTIPLE AREAS.CRCKD&DTACHD CONCRT/MASRY FIRPRFNG ENCSMNT@BSMNT FRMNG CELLR COLMS.IMMED PRFRM NYSPE EVAL ENTIR CLLR&BSMNT LVLS INCLD EXTERIOR AREAWYS.CLOS OFF IUNSAF AREA,IMMED NOTFY DOB IMPCK EGRESS
DOB07/31/2023EMERGENCY WORK-CITY OWNED BUILDING-MEN'S SHELTER BASEMENT FLRFRMING& SLABS&CELLAR LVL COLMN STAT DISRPR.UNDRSID SLABS-SPALLS W/SEVRL DETERIOR MESH EXPOSD MULTI LOCATNS.CRACKD/SPALD CONCRT ENCASMNT@ UNDERSD.IMMED INSTL TEMP SHORING&BRACNG OR STRCTRL COLM REINFORCMNT@ DRECTN NYSPE.ALL WRK DIRCT SUPRVSD/DIRCTD ONSITE PE
DOB07/31/2023FTM.BSMNT&CELLAR LVLS IN A STATE OF DISREPAIR.UNDERSIDE OF HAVE SPALLS W/SEVERELY DTERIORATD MESH EXPOSD IN MULT AREAS.CRCKD&DTACHD CONCRETE/ MASONRY FIREPROOFNG ENCASEMENT@BSMNT FRAMNG&CELLAR.1.NYSPE STRCTRL ENG TO IMMED EVAL ENT BLDG&DSIGN RPRS,2.FILE FOR RPRS BY 12/1/23,3.OBTN PRMTS&STRT RPRS BY 12/18/23,4.CMPLTE RPRS&SGN OFF PRMTS BY 12/20/24
DOB07/31/2023EMERGENCY WORK-CITY OWNED BUILDING-MEN'S SHELTER BASEMENT FLRFRMNG& SLABS&CELLAR LVL-DISRPR STATE.UNDERSID SLABS-SPALLS W/SEVERL DETERIOR MESH EXPSD MULT LOCATIONS.CRACKD/SPALD CONCRT ENCASMNT@UNDRSD OF BSMNT LVL STEEL BMS.NYSPE IMMED EVAL ENTIR STRCTR&SURVYOVRHD HAZ@ CELLAR&BASEMENT LVLS.IMMED PROB BSMNT FL STEEL BMS@LOCTNS PER PE&TERRA
DOB07/31/2023FTM.BSMNT&CELLAR LVLS IN A STATE OF DISREPAIR.UNDERSIDE OF HAVE SPALLS W/SEVERELY DTERIORATD MESH EXPOSD IN MULT AREAS.CRCKD&DMGD CONCRETE/ MASONRY FIREPROOFNG ENCASMNT@BSMNT FRAMNG&CELLAR COLUMNS.1.NYS PE STRCTRL ENG TO IMMED EVAL ENT BLDG&DSGN RPRS,2.FILE FOR RPRS BY12/1/23 3.OBTN PRMTS&STRT RPRS BY 12/18/23
DOB07/31/2023EMERGENCY WORK.BSMNT&CELLAR LVLS IN A STATE OF DISREPAIR UNDERSIDE OF SLABS HAVE STALLS W/SEVERELY DTERIORATD MESH EXPOSD IN MULT AREAS, CRCKD&DTACHD CONC/MASONRY FIREPROOFNG ENCASMNT@BSMNT FRMNG.IMMED PERFORM THE FOLLOWNG:1.NYS PE STRCTRL ENGNEER TO EVAL ENT CELLAR&BSMNT LVLS INCLDNG EXT ARE ALWAYS,2.CLOSE OFF UNSAFE AREAS @CELLAR&BSMNT LVL
ECB04/21/2021FAILURE TO MAINTAIN BUILDING IN CODE COMPIANT MANNER NOTE AT CELLAR LEVEL OBSERVED ON CEILING SPALLING CONCRETE MISSING AND EXPOSING REBARAL SO SOME COLUMNS HAVE CONCRETE MISSING REPAIR AND OR REPLACE$12K due
DOB04/01/2020V-DOB VIOLATION - ACTIVE
DOB04/01/2020V-DOB VIOLATION - ACTIVE
DOB04/01/2020V-DOB VIOLATION - ACTIVE
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
ECB05/20/2019FAILURE TO INSTALL TEMPORARY WIRING AS PER SECTION. OBSERVED ON 30 ST ENTRANCE IN FRONT OF GATE LIGHTS AND CONDUITS NOT SUPPORTED/SECURED ASREQUIRED; ALSO NOTED EMT CONDUITS DISCONNECTED AND NOT PROVIDING ELEC$8K due
DOB10/01/2018THE DOB INTENDS TO REVOKE ALL APPROVALS AND PERMITS UNDER PLUMBING ARA #110267791 DUE TO SUSPENSION OF MASTER PLUMBERS LICENSE. STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT AND OBTAIN A NEW MASTER PLUMBER TO SUPERSEDE THE PLUMBING PERMIT
DOB10/01/2018THE DOB INTENDS TO REVOKE ALL APPROVALS AND PERMITS UNDER PLUMBING ARA #110261029 DUE TO SUSPENSION OF MASTER PLUMBERS LICENSE. STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT AND OBTAIN A NEW MASTER PLUMBER TO SUPERSEDE THE PLUMBING PERMIT
DOB10/01/2018THE DOB INTENDS TO REVOKE ALL APPROVALS AND PERMITS UNDER PLUMBING LAA #110558888 DUE TO SUSPENSION OF MASTER PLUMBERS LICENSE. STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT AND OBTAIN A NEW MASTER PLUMBER TO SUPERSEDE THE PLUMBING PERMIT
DOB10/01/2018THE DOB INTENDS TO REVOKE ALL APPROVALS AND PERMITS UNDER PLUMBING LAA #110261029 DUE TO SUSPENSION OF MASTER PLUMBERS LICENSE. STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT AND OBTAIN A NEW MASTER PLUMBER TO SUPERSEDE THE PLUMBING PERMIT
DOB10/01/2018THE DOB INTENDS TO REVOKE ALL APPROVALS AND PERMITS UNDER PLUMBING LAA #122321585 DUE TO SUSPENSION OF MASTER PLUMBERS LICENSE. STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT AND OBTAIN A NEW MASTER PLUMBER TO SUPERSEDE THE PLUMBING PERMIT
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB09/15/2017V-DOB VIOLATION - ACTIVE
DOB08/15/2017V-DOB VIOLATION - ACTIVE
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB03/01/2016V-DOB VIOLATION - ACTIVE
DOB02/10/2016EXIT DOOR NOT SELF CLOSING, THE FOLLOWING DOORS NOT SELF CLOSING 2ND FLOOR, 2W-78, 2W-82, 2W-83, 2W-88, 2W-87, 2E-58, 3RD FLOOR 3E-47, 3E-39, 3E-48, 3E-49,. 3E-51, 3E-26, 3E-14, 4TH FLOOR 4W-87, 4W-91, 4E-51, 4E-48, 5TH FLOOR 5E-49, 6TH FLOOR 6E-16, 6E-17, 6W-78, 7TH FLOOR 7E-40, 8TH FLOOR 8C-04 & MAIN ENTRY DOORS @ 1ST FLOOR
DOB07/29/2015V-DOB VIOLATION - ACTIVE
DOB07/29/2015V-DOB VIOLATION - ACTIVE
DOB07/29/2015V-DOB VIOLATION - ACTIVE
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB12/31/2013FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
DOB03/05/2013V-DOB VIOLATION - ACTIVE
DOB03/05/2013V-DOB VIOLATION - ACTIVE
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
DOB12/13/2011VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
DOB10/08/2010V-DOB VIOLATION - ACTIVE
DOB03/31/2008V-DOB VIOLATION - ACTIVE
DOB03/31/2008V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB06/30/2025FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED WOOD BARRICADE INSTALL AT STAIRWELL LEADING INTO THE BASEMENT. POTENTIAL FIRE HAZARD., REMOVE OBSTRUCTIONNothing owed — awaiting certificate of correction
ECB06/30/2025CLASS 2 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE.Nothing owed — awaiting certificate of correction
ECB06/30/2025CLASS 2 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE.Nothing owed — awaiting certificate of correction
ECB06/30/2025CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. ALARM BUTTON MISSING IN CAR OPERATING PANEL. HOIST ROPES SHOWING SIGN OF ROUGE. ADJUST/REPLACE HOISTWAY DOOR RELEASE ROLLERS ON 9TH FLOOR. COUNTERWEIGHT RUNBY ATNothing owed — awaiting certificate of correction
ECB06/30/2025CLASS 2 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE.Nothing owed — awaiting certificate of correction
ECB06/30/2025CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. FIRE HAT FEATURE FOR PHASE 1 IS MISSING. PROVIDE A CONTRAST SIGN FOR MACHINE ROOM DOOR. HOIST ROPES SHOWING SIGN OF ROUGE. CLEAN HOIST MACHINE. PROVIDE AN UPDATENothing owed — awaiting certificate of correction
ECB12/05/2024: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CALL THE DOB ELEVATOR DIVISION AT (212) 393-2144 OR EMAIL AT EINothing owed — awaiting certificate of correction
ECB12/05/2024: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CALL THE DOB ELEVATOR DIVISION AT (212) 393-2144 OR EMAIL AT EINothing owed — awaiting certificate of correction
ECB12/05/2024: IN-CAR COMMUNICATION INOPERATIVE. HOIST ROPES SHOW SIGNS OF ROUGE. RELAMP MACHINE ROOM LIGHTING. PROVIDE A UPDATED MAINTENANCE LOG.Nothing owed — awaiting certificate of correction
ECB12/05/2024DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, CALL OR EMAILTHE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT (212) 393-2144 FOR A RENothing owed — awaiting certificate of correction
ECB12/05/2024: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CALL THE DOB ELEVATOR DIVISION AT (212) 393-2144 OR EMAIL AT EINothing owed — awaiting certificate of correction
ECB12/05/2024IN-CAR COMMUNICATION INOPERATIVE. PROVIDE TO GAIN APROVCCESS TO ELEVATOR MACHINE ROOM AND OVERHEAD FOR INSPECTION.Nothing owed — awaiting certificate of correction
ECB12/05/2024IN-CAR COMMUNICATION AND ALARM BELL INOPERATIVE. CLASS 2 ITEMS: HOIST ROPES SHOWING SIGNS OF ROUGE. PROVIDE A SIGN ON ELEVATOR MACHINE ROOM DOOR. REPLACE BASEMENT CAR BUTTON.Nothing owed — awaiting certificate of correction
ECB10/31/2022ELECTRICAL BRAKE MONITORING SWITCH DEFECTIVE NOT WORKING TAMPERED WITH DISABLED(CU).Nothing owed — awaiting certificate of correction
ECB10/31/2022UPON INSPECTION THE DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.Nothing owed — awaiting certificate of correction
ECB10/31/2022UPON INSECTION THE DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.Nothing owed — awaiting certificate of correction
ECB10/31/2022AT 6TH FL, SMOKE DOORS NEAR 6W-89RM, 6C-58 RM, AT 5TH FL,SMOKE DOORS NEAR STAIRCASE E, 5E-11RM, 5W-72, AT 4TH FL, SOMOKE DOORS NEAR 4C-02RM, 4C-65RM, 4W-72RM, 4E-15RM, 4E-52RM, AT 3RD FL, EXIT DOOR STAIRCASE C,Nothing owed — awaiting certificate of correction
ECB10/31/2022I OBSERVED ON THE 30TH STREET SIDE OF THE SIDEWALK SHED, THE IMPROPER INSTALLATION OF POWER AND LIGHTS. THERE IS NO GFCI PROTECTION TO THAT SECTION OF THE SIDEWALK SHED AND THE LIGHTS AND POWER ARE IMPROPERLY SNothing owed — awaiting certificate of correction
ECB10/31/2022UPON INSPECTION THE DEVCIE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILBINGS.NYC.GOV FOR A COMPLETE INSPECTION.Nothing owed — awaiting certificate of correction
ECB10/31/2022ELECTRICAL BRAKE MANITORING SWITCHES DEFECTIVE NOT WORKING TAMPERED WITH DISABLED(CU). EMERGENCEY ALARM BELL NO BUZZER. EMERGENCY STOP SWITCH DEFECTIVE NO BUZZER.Nothing owed — awaiting certificate of correction
ECB10/31/2022UPON INSPECTION THE DEVICE WAS FOUND OUT OF SERVICE . RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.Nothing owed — awaiting certificate of correction
ECB06/07/2022EXISTING DOORS AT 7TH FL, STAIR C , 6TH FL STAIR A, DOOR NEAR 6E-23, DOOR NEAR ELEVATOR D, DOOR NEAR STAIR E, DOOR NEAR 5E-11 RM, AT 5TH FL, STAIR A, DOOR NEAR 5W-72 RM, AT 4TH FL, DOOR NEAR 4C-02 RM, DOOR NEARNothing owed — awaiting certificate of correction
ECB10/15/2021DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). NO ACCESS TO THE MACHINE ROOM. IT WAS COVERED WITH PLYWOOD.Nothing owed — awaiting certificate of correction
ECB10/15/2021FIX WATER LEAK OVER THE MACHINE. REMOVE ALL PLASTIC AND WOOD THAT'S COVERING THE MACHINE.Nothing owed — awaiting certificate of correction
ECB10/15/2021DOOR ZONE RESTRICTOR TAMPERED WITH DISABLED (CU). BRAKE TAG NEEDS TO BE UPDATED. FIX WATER LEAK OVER THE CONTROLLER . FIX WATER LEAK OVER THE MACHINE. REMOVE ALL PLASTIC AND WOOD THAT'S COVERING THE MACHINE ANDNothing owed — awaiting certificate of correction
ECB09/10/2021AN UNLAWFUL ACT.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS#35414815Z ISSUED ON 4/26/2019 FORFAILURE TO PROPERLY INSTALL TEMPORARY WIRING.ALSO SUMMONS#35414816K ISNothing owed — awaiting certificate of correction
ECB08/12/2021EXISTING EMERGENCY LIGHTS WITH BACK UP BATTERY AT &TH FLOOR, NEAR ELEVATOR B WAS NO OPERATIONAL WHEN TESTED., REPAIR AND/OR REPLACE LIGHTINGNothing owed — awaiting certificate of correction
ECB08/12/2021UPON INSPECTION THE DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.Nothing owed — awaiting certificate of correction
ECB08/12/2021SMOKE DOOR DO NOT SELF CLOSE AT 6TH FL NEAR RM 6C-54 AND NEAR ELEVATOR B, AT 5TH FL NEAR RM 5W-71, AT 4TH FL NEAR RM 4W-72, RM 4W-113, 4E-15, AT SECOND FL NEAR RM 2E-53., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB01/19/2021FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT CELLAR LEVEL OBSERVED ON CEILING SPALLING CONCRETE MISSING AND EXPOSING REBARALSO SOME COLUMNS HAVE CONCRETE MISSING. REMEDY: REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
ECB11/17/2020FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIO#35500683R ISSUED ON 9/29/2020 AND TO FILE A CERTIFICATE OF CORRECTIONPURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO MAINTAIN BUILDING INNothing owed — awaiting certificate of correction
ECB11/13/2020DOOR ZONE RESTRICTOR NEEDED TO BE ADJUSTED TRAPPING HAZARD (CU). NO DLM TAG ON THE CONTROLLER. BRAKE TAG EXPIRED 9/3/19. WATER LEAK OVER THE CONTROLLER. ALARM BELL MISSING THE BUTTON CAR STATION.Nothing owed — awaiting certificate of correction
ECB11/13/2020DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED (CU). BRAKE TAG EXPIRED. IN CAR POSITION INDICATOR DEFECTIVE. EMERGENCY STOP SWITCH NO BUZZER. ALARM BELL NO BUZZER.Nothing owed — awaiting certificate of correction
ECB11/13/2020DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED (CU). NO DLM TAG . WIRE OFF THE BOARD .Nothing owed — awaiting certificate of correction
ECB09/29/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT CELLAR LEVEL OBSERVED MISSING AND SPALLING CONCRETE ON CEILING EXPOSING REBARALSO SOME COLUMNS HAVE MISSING CONCRETE. REMEDY: REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
ECB07/23/2020DEVICE NOT RUNNING SITTING WITH THE ROPE GRIPPER TRIPPED. REPAIR AND RESTORE TO SERVICE IMMEDIATELY.Nothing owed — awaiting certificate of correction
ECB02/18/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT CELLAR LEVEL EAST SIDE OF BLDG SPALLING AND MISSING CONCRETE FROM CEILING EXPOSING REINFORCEMENT BEAMS ALSO SOME COLUMNS HAVE CONCRETE MISSING THRONothing owed — awaiting certificate of correction
ECB01/08/2020FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE OBSERVED ATBASEMENT LEVEL EAST SIDE SPALLING AND MISSING CONCRETE FROM CEILING EXPOSING REINFORCEMENT BEAMS ALSO SOME COLUMS HAVE CONCRETE MISSING THRONothing owed — awaiting certificate of correction
ECB11/29/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION I OBSERVED AT BASEMENT LEVEL SPALLING CONCRETE FALLING FROM THE CEILING EXPOSED REINFORCEMENT BEAM AND PARTIALLY COLLAPSED CEINothing owed — awaiting certificate of correction
ECB11/12/2019NOTED: OBSERVED THROUGHOUT CELLAR, SPALLING AND MISSING CONCRETE EXPOSING REINFORCEMENT BARS AND STEEL BEAMS COMPROMISING FIREPROOFING OF STRUCTURE COMPONENTS THROUGHOUT CELLAR. , REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB11/12/2019JIM CAPS INSTALLED THROUGHOUT THE CELLAR., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB11/12/2019NOTED: OBSERVED CRACKS AND SHIFTED BRICKS THROUGHOUT EXTERIOR OF ROOF BULKHEAD, ELEVATOR MACHINE ROOM AND ELEVATOR MOTOR ROOM. , MAINTAIN EXTERIOR BUILDING WALLNothing owed — awaiting certificate of correction
ECB11/12/2019NOTED: EXISTING EMERGENCY LIGHTS WERE NOT OPERATIONAL WHEN TESTED, AT 6TH FLOOR STAIR D, FIFTH FLOOR STAIR C AND B, 4TH FLOOR STAIR E, 3RD FLOOR STAIR A AND VARIOUS OTHER LOCATIONS THROUGHOUT BUILDING. , REPAIRNothing owed — awaiting certificate of correction
Home for indigent children, aged, homeless · 80,000 sf lot · 6 FAR built · Flood zone X