← Back
Two family brick
402 EAST 16 STREET
BROOKLYN · BIN 3118719
💬 Discuss this project
1901Year Built
3Stories
B1Building Class
R6AZoning
2,592 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family brick · 1,500 sf lot · 1.73 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/11/2022$1.4M—Private party → Private party$559/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBM AND ASSOCIATES212/20/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L L CONSULTING SERVICES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CLASSIC CONSTRUCTION NY*General Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENTHINK ENGINEERS LLC6247212/20/2022
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (3)
01/27/2023
Signed off — Alteration
1. Removal of non-bearing wall or partitions at 1st fl. as shown on the plan. 2. Removal of a bearing wall partition at 1st fl. as shown on the plan and the installation of beam supports and posts. 3. Reinforce. of exist. wood girder at cel. w/steel
B08013113-I1
12/20/2022
Filed — Alteration
1. Removal of non-bearing wall or partitions at 1st fl. as shown on the plan. 2. Removal of a bearing wall partition at 1st fl. as shown on the plan and the installation of beam supports and posts. 3. Reinforce. of exist. wood girder at cel. w/steel
B08013113-P1
12/20/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Sunil Saigal
12/20/2022
Special inspection requirement — Structural Steel - Details
Sunil Saigal
12/20/2022
Special inspection requirement — Final
Sunil Saigal
11/04/2022
Permit issued — Structural
B08013113-I1-ST
09/30/2022
Filed — Alteration
1. Removal of non-bearing wall or partitions at 1st fl. as shown on the plan. 2. Removal of a bearing wall partition at 1st fl. as shown on the plan and the installation of beam supports and posts. 3. Reinforce. of exist. wood girder at cel. w/steel
B08013113-I1
10/29/2004
Violation issued (ECB, open)
Construction
11/09/1993
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offCLASSIC CONSTRUCTION NY*11/04/2022
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/20/2022Structural Stability – Alterations of existing buildingsSunil Saigalspecial
12/20/2022Structural Steel - DetailsSunil Saigalspecial
12/20/2022FinalSunil Saigalprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B08013113-P1Request digital key ↗
08/28/2026B08013113-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026B08013113-P1Open ↗
08/28/2026B08013113-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/26/2026B08013113-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/26/2026B08013113-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/28/2026B08013113-I1Open ↗
08/28/2026B08013113-P1Open ↗
▸Other Documents1
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B08013113-I1Open ↗