← Back
One story retail building
4021 GLENWOOD ROAD
BROOKLYN · BIN 3114433
💬 Discuss this project
1930Year Built
1Stories
K1Building Class
R4Zoning
3,800 sfGross Floor Area
4Units
4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
One story retail building · Owner of record: 4023 GLENWOOD ROAD LLC · 3,800 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 12p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHEUNG CHUN RLTY CORP203/22/2026
4023 GLENWOOD ROAD LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/23/2019$774K—Private party → MB 4021 GW LLC$204/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SUNG HO SHIN ARCHITECT, PC103/07/2025
ARQUITECTURA VARELA201/09/2023
BILLAH ENGINEERING PLLC108/08/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CM3 DESIGN STUDIO203/21/2026
INSHA BUILDING CONSULTANTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
3 DESIGN HOME IMPROV INCGeneral Contractor107/08/2026
PETER PLUMBING ASSOC. INC.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BILLAH ENGINEERING5838108/08/2022
Building Lifecycle
All (50)Filed (4)Permit Issued (2)Violation (30)Inspection (4)Objection (3)Special Inspection (7)
11/06/2025
Violation issued (FDNY_NOV, closed)
05/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/11/2025
Objection raised — Scope
03/07/2025
Filed — Alteration
Resolve ECB violations 35107933J, 35107917J. Repair exterior cracked brick wall and missing mortar.
B01180828-I1
02/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/18/2025
Special inspection requirement — Air barrier - visual inspection
11/01/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/09/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
10/26/2023
Violation issued (FDNY_NOV, closed)
10/26/2023
Violation issued (FDNY_NOV, closed)
10/26/2023
Violation issued (FDNY_NOV, closed)
10/04/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/14/2023
Permit issued — Plumbing
B00806697-S1-PL
06/29/2023
Violation issued (ECB, closed)
Construction
05/04/2023
Violation issued (FDNY_NOV, closed)
05/04/2023
Violation issued (FDNY_NOV, closed)
04/13/2023
Permit issued — General Construction
B00806697-I1-GC
01/09/2023
Filed — Alteration
APPLICATION TO LEGALIZE WORK ON COMMERCIAL STORE LOCATED ON FIRST FLOOR AS SHOWN IN PLANS FILED HEREWITH. APPLICATION TO SUPERSEDE APPLICATION # 321953132
B00806697-S1
01/04/2023
Filed — Alteration
APPLICATION TO LEGALIZE WORK ON COMMERCIAL STORE LOCATED ON FIRST FLOOR AS SHOWN IN PLANS FILED HEREWITH. APPLICATION TO SUPERSEDE APPLICATION # 321953132
B00806697-I1
01/03/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Vicente Varela
01/03/2023
Special inspection requirement — Final
Vicente Varela
01/03/2023
Special inspection requirement — Fenestration areas
Vicente Varela
01/03/2023
Special inspection requirement — Insulation placement and R values
Vicente Varela
01/03/2023
Special inspection requirement — Fenestration air leakage
Vicente Varela
08/22/2022
Objection raised — Inspections
08/22/2022
Objection raised — Scope
08/08/2022
Filed — Alteration
FILING FOR INTERIOR RENOVATION AT EXISTING CORNER COMMERCIAL SPACE USE, REPLACING FLOOR TILES, REPLACING EXHAUST RANGE HOOD, AND RELATED DUCT WORK AS PER PLANS. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00784337-I1
06/09/2022
Violation issued (FDNY_NOV, closed)
12/10/2021
Violation issued (ECB, closed)
Construction
10/21/2021
Violation issued (ECB, closed)
Construction
08/23/2021
Violation issued (ECB, closed)
Construction
07/28/2021
Violation issued (FDNY_NOV, closed)
07/16/2021
Violation issued (ECB, closed)
Construction
06/15/2021
Violation issued (ECB, closed)
Construction
05/27/2021
Violation issued (ECB, closed)
Construction
04/02/2021
Violation issued (ECB, closed)
Construction
03/23/2021
Violation issued (FDNY_NOV, closed)
03/23/2021
Violation issued (FDNY_NOV, closed)
12/15/2020
Violation issued (ECB, closed)
Construction
10/01/2020
Violation issued (FDNY_NOV, closed)
05/15/2020
Violation issued (FDNY_NOV, closed)
12/12/2019
Violation issued (ECB, closed)
Construction
08/07/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/15/2019
Violation issued (ECB, closed)
Construction
05/15/2019
Violation issued (ECB, closed)
Construction
02/11/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/20/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/28/2014
Violation issued (ECB, open)
Construction
08/19/2014
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedPETER PLUMBING ASSOC. INC.07/14/2023
DOB NOWGeneral ConstructionPermit Issued3 DESIGN HOME IMPROV INC04/13/2023
BISEQISSUEDSUPERIOR FIRE CONTROL INC05/23/2019
BISMHISSUEDSUPERIOR FIRE CONTROL INC05/22/2019
BISOTISSUEDSUPERIOR FIRE CONTROL INC04/23/2019
BISMHISSUEDSUPERIOR FIRE CONTROL INC04/09/2019
BISEQISSUEDSUPERIOR FIRE CONTROL INC04/09/2019
BISFPISSUEDMASTER FIRE SYSTEMS, INC03/12/2010
BISFPISSUEDNY BUS FIRE SYST05/08/2000
1 project · most recent 08/08/2022
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/08/2022——Ventilation Systems
Ventilation
Captiveaire NCA16FA 2,800 CFM · Exhaust Fan ×1
1 project · most recent 01/09/2023
Water/Sanitary
FiledStatusContractorScope
01/09/2023Permit IssuedPETER PLUMBING ASSOC. INCWater/Sanitary
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/01/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/09/2024Pass-Final PL - UndergroundPassView ↗
08/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
02/18/2025Fire-Resistant Penetrations and Joints—special
02/18/2025Air barrier - visual inspection—energy_progress
01/03/2023Fenestration and door U-factor and product ratingsVicente Varelaenergy_progress
01/03/2023FinalVicente Varelaprogress
01/03/2023Fenestration areasVicente Varelaenergy_progress
01/03/2023Insulation placement and R valuesVicente Varelaenergy_progress
01/03/2023Fenestration air leakageVicente Varelaenergy_progress
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/28/2026B00806697-S1Request digital key ↗
08/28/2026B00806697-I1Request digital key ↗
08/15/2026B01180828-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits11
▸BISWORK PERMIT APPLICATION7
05/31/2019321953132Open ↗
05/29/2019321953132Open ↗
05/28/2019321953132Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
03/01/2021321953132Open ↗
04/10/2019321953132Open ↗
12/20/2016321291179Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026B00806697-I1Open ↗
08/27/2026B00806697-I1Open ↗
08/27/2026B00806697-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/22/2026B01180828-I1Open ↗
08/13/2026B00806697-I1Open ↗
08/13/2026B00784337-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/10/2019321953132Open ↗
12/20/2016321291179Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/10/2019321953132Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
04/10/2019321953132Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/10/2019321953132Open ↗
12/20/2016321291179Open ↗
▸BISSCHEDULE B - PLUMBING1
03/01/2021321953132Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/10/2019321953132Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/15/2026B01180828-I1Open ↗
08/13/2026B00806697-I1Open ↗
08/13/2026B00806697-S1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/10/2019321953132Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/27/2010320123317Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
04/10/2019321953132Open ↗
12/20/2016321291179Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
01/27/2010320123317Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
04/10/2019321953132Open ↗
12/20/2016321291179Open ↗
01/27/2010320123317Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET3
05/07/2019321953132Open ↗
12/20/2016321291179Open ↗
01/27/2010320123317Open ↗