← Back
Two family converted from one family
404 ADELPHI STREET
BROOKLYN · BIN 3055856
💬 Discuss this project
1901Year Built
3Stories
B3Building Class
R6BZoning
2,268 sfGross Floor Area
2Units
Two family converted from one family · 1,850 sf lot · 1.23 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof17p · 1 filing · 20 docs
Floor 316p · 1 filing · 20 docs
Floor 215p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar16p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/06/2021$1.8M—— → —$772/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALBANNA ENGINEERING PC309/27/2023
BARKER FREEMAN DESIGN OFFICE406/21/2023
DANIEL R. WAPNER PE., P.C.105/17/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
4444 PPPP CORP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ABA INNOVATIVE BUILDERS IGeneral Contractor1407/08/2026
S & L PLUMBING INCPlumbing407/08/2026
ALEXANDRA BARKERElectrical103/21/2026
ALEX WUElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALBANNA ENGINEERING PC2401209/27/2023
BARKER FREEMAN DESIGN OFF3442206/21/2023
Building Lifecycle
All (49)Filed (8)Permit Issued (8)Signed Off (4)Inspection (7)Objection (2)Special Inspection (20)
09/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/04/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/18/2023
Signed off — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-S2
10/10/2023
Signed off — Alteration
pipe scaffold as per plans
B00739850-I1
09/27/2023
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-P3
09/22/2023
Signed off — Alteration
B00688397-I1
09/21/2023
Signed off — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-S1
08/28/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Mechanical Systems
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Final
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Energy Code Compliance Inspections
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Interior lighting power
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Air barrier - visual inspection
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — HVAC-R and service water heating equipment
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — HVAC-R and service water heating system controls
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Permanent certificate
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Air barrier — testing
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Ventilation and air distribution system
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Fenestration areas
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Insulation placement and R values
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Maintenance information
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ALEXANDRA BARKER
06/26/2023
Special inspection requirement — Metering
ALEXANDRA BARKER
06/21/2023
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-P1
06/21/2023
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-P2
06/02/2023
Special inspection requirement — Energy Code Compliance Inspections
ALEXANDRA BARKER
06/02/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ALEXANDRA BARKER
04/20/2023
Permit issued — Plumbing
B00546747-S1-PL
04/04/2023
Permit issued — General Construction
B00546747-I1-GC-CX
04/04/2023
Permit issued — Construction Fence
B00688397-I1-FN
10/31/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/31/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/13/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/13/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/02/2022
Permit issued — Plumbing
B00546747-S1-PL
05/19/2022
Permit issued — Supported Scaffold
B00739850-I1-SF
05/17/2022
Filed — Alteration
pipe scaffold as per plans
B00739850-I1
05/09/2022
Permit issued — Earth Work
B00546747-S2-GC-CX
03/04/2022
Permit issued — Construction Fence
B00688397-I1-FN
02/28/2022
Filed — Alteration
B00688397-I1
02/16/2022
Permit issued — Mechanical Systems
B00546747-I1-GC-CX
10/07/2021
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-S2
07/28/2021
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-S1
07/26/2021
Objection raised — Accessibility
07/26/2021
Objection resolved — Addressed
07/20/2021
Filed — Alteration CO
RENOVATION OF TWO FAMILY TO RESTORE PRIOR LEGAL USE OF ONE FAMILY AS DESCRIBED. Interior partitions, GWB,tilework,trim & cosmetic finishes. Exterior, rear yd steel deck &stairs,modify openings & sunken area in rear yard, new roof hatch, skylight on roof.
B00546747-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offS & L PLUMBING INC04/20/2023
DOB NOWGeneral ConstructionPermit IssuedABA INNOVATIVE BUILDERS I04/04/2023
DOB NOWConstruction FenceSigned-offABA INNOVATIVE BUILDERS I04/04/2023
DOB NOWPlumbingSigned-offS & L PLUMBING INC06/02/2022
DOB NOWSupported ScaffoldSigned-offABA INNOVATIVE BUILDERS I05/19/2022
DOB NOWEarth WorkSigned-offABA INNOVATIVE BUILDERS I05/09/2022
DOB NOWConstruction FenceSigned-offABA INNOVATIVE BUILDERS I03/04/2022
DOB NOWMechanical SystemsPermit IssuedABA INNOVATIVE BUILDERS I02/16/2022
BISOTISSUEDBROOKLYN SOLARWORKS LLC03/14/2023
1 project · most recent 09/27/2023
Air Conditioning Systems Associated Ducts and Piping Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
09/27/2023Permit IssuedABA INNOVATIVE BUILDERS IAir Conditioning Systems, Associated Ducts and Piping, Heating Systems
Cooling
Fujitsu AOU36RLXFZ1 36,000 BTU · Split System ×6
Heating
Laars LAARS FT Series Model #: MFTCW199NA2XN 181,000 BTU · Boiler ×2
Ducts & Piping
N/A n/a ×2
1 project · most recent 09/27/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/27/2023Signed-offCASE PLUMBING LLCGas, Storm, Water/Sanitary
3 projects · most recent 09/06/2023
General Wiring
FiledStatusContractorScope
09/06/2023CompleteFIRST STAR ELECTRIC INCGeneral Wiring
08/29/2023CancelledFIRST STAR ELECTRIC INCGeneral Wiring
04/05/2023CompleteBROOKYLN SOLARWORKS, LLC—
1 project · most recent 09/27/2023
Steel Concrete Masonry Wood
FiledStatusContractorScope
09/27/2023Signed-offCASE PLUMBING LLCSteel, Concrete, Masonry, Wood
1 project · most recent 09/27/2023
Earthwork
FiledStatusContractorScope
09/27/2023Signed-offCASE PLUMBING LLCEarthwork
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/04/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/31/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/31/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/13/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/13/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
06/26/2023Fire-Resistant Penetrations and JointsALEXANDRA BARKERspecial
06/26/2023Mechanical SystemsALEXANDRA BARKERspecial
06/26/2023FinalALEXANDRA BARKERprogress
06/26/2023Fire-Resistance Rated ConstructionALEXANDRA BARKERprogress
06/26/2023Energy Code Compliance InspectionsALEXANDRA BARKERprogress
06/26/2023Fenestration and door U-factor and product ratingsALEXANDRA BARKERenergy_progress
06/26/2023Interior lighting powerALEXANDRA BARKERenergy_progress
06/26/2023Air barrier - visual inspectionALEXANDRA BARKERenergy_progress
06/26/2023HVAC-R and service water heating equipmentALEXANDRA BARKERenergy_progress
06/26/2023HVAC-R and service water heating system controlsALEXANDRA BARKERenergy_progress
06/26/2023Permanent certificateALEXANDRA BARKERenergy_progress
06/26/2023Air barrier — testing ALEXANDRA BARKERenergy_progress
06/26/2023Ventilation and air distribution systemALEXANDRA BARKERenergy_progress
06/26/2023Fenestration areasALEXANDRA BARKERenergy_progress
06/26/2023Insulation placement and R valuesALEXANDRA BARKERenergy_progress
06/26/2023Maintenance informationALEXANDRA BARKERenergy_progress
06/26/2023HVAC-R and service water piping design and insulationALEXANDRA BARKERenergy_progress
06/26/2023MeteringALEXANDRA BARKERenergy_progress
06/02/2023Energy Code Compliance InspectionsALEXANDRA BARKERprogress
06/02/2023HVAC-R and service water piping design and insulationALEXANDRA BARKERenergy_progress
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
09/01/2026B00546747-P2Request digital key ↗
09/01/2026B00546747-P3Request digital key ↗
09/01/2026B00546747-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
03/13/2023340882263Open ↗
▸BISWORK PERMIT APPLICATION1
03/14/2023340882263Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00546747-I1Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/31/2026B00688397-I1Open ↗
08/13/2026B00546747-P1Open ↗
08/13/2026B00546747-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
08/23/2026B00546747-P3Open ↗
08/23/2026B00546747-P3Open ↗
08/23/2026B00546747-P3Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/23/2026B00546747-P3Open ↗
08/23/2026B00546747-P3Open ↗
08/23/2026B00546747-P3Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/13/2023340882263Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist4
08/13/2026B00546747-P2Open ↗
08/13/2026B00546747-I1Open ↗
08/13/2026B00546747-P3Open ↗
Showing 3 of 4 on file for this type
▸BISTPP1: TENANT PROTECTION PLAN1
03/14/2023340882263Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/13/2026B00546747-S1Open ↗
08/13/2026B00546747-I1Open ↗
08/13/2026B00546747-S2Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/13/2023340882263Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
06/06/2023340882263Open ↗
03/13/2023340882263Open ↗
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00546747-S1Open ↗
08/13/2026B00546747-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/06/2023340882263Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
06/07/2023340882263Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
03/13/2023340882263Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/06/2023340882263Open ↗
03/14/2023340882263Open ↗
03/13/2023340882263Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026B00546747-P3Open ↗
08/13/2026B00546747-S2Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00546747-S2Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00546747-S2Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/07/2023340882263Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/07/2023340882263Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/06/2023340882263Open ↗
03/13/2023340882263Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
03/14/2023340882263Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/13/2023340882263Open ↗
▸Other Documents1
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00546747-S2Open ↗