← Back
Two family brick
404 CLASSON AVENUE
BROOKLYN · BIN 3056385
💬 Discuss this project
1899Year Built
2.5Stories
B1Building Class
R6BZoning
2,592 sfGross Floor Area
2Units
1 Open Violation ▸
Two family brick · 2,000 sf lot · 1.3 FAR built · Flood zone X
Locations of Work
PlumbingCivil
Floor 31p · 1 filing · 11 docs
Floor 2
Floor 11p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AKT DESIGNS LLC408/01/2024
URBAN INTEGRATIONS103/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NOEL BUILDING CONSULTING INC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BLUESKY CONST. & CONSULTINGGeneral Contractor404/09/2026
AMOS & CLIVE CONSTRUCTIONGeneral Contractor107/08/2026
DRAKES CARPENTRY & WOOD**General Contractor104/09/2026
BENT MECHANICAL CORPPlumbing107/08/2026
SAMUEL & SONS P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIZA WORKS OF ARCH PLLC6101408/01/2024
URBAN INTEGRATIONS LLC7993203/06/2023
Building Lifecycle
All (49)Filed (5)Permit Issued (6)Signed Off (3)Violation (3)Inspection (4)Objection (16)Special Inspection (12)
07/30/2026
Signed off — Alteration
Renovation existing kitchen. Installation of new kitchen fixtures. No change of use, egress or occupancy under this application.
B08054111-I1
07/28/2026
Signed off — Alteration
Renovation of existing Kitchen and Install new rear metal deck. New walls, cabinets and floor finishes. No change of use, egress or occupancy under this application.
B08054101-I1
02/14/2025
Signed off — Alteration
B08054150-I1
09/10/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nicolas Zapata
08/01/2024
Filed — Alteration
Renovation existing kitchen. Installation of new kitchen fixtures. No change of use, egress or occupancy under this application.
B08054111-P2
07/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nicolas Zapata
05/21/2024
Permit issued — Structural
B08054150-I1-ST
03/28/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/22/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/23/2024
Filed — Alteration
Renovation existing kitchen. Installation of new kitchen fixtures. No change of use, egress or occupancy under this application.
B08054111-P1
01/02/2024
Permit issued — General Construction
B08054101-I1-GC
12/27/2023
Permit issued — Plumbing
B08054111-I1-PL
11/16/2023
Permit issued — Plumbing
B08054111-I1-PL
10/03/2023
Permit issued — Structural
B08054150-I1-ST
09/29/2023
Permit issued — General Construction
B08054101-I1-GC
03/16/2023
Objection raised — Admin
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Scope
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/16/2023
Objection raised — Other
03/16/2023
Objection resolved — Addressed
03/06/2023
Filed — Alteration
B08054150-I1
03/01/2023
Filed — Alteration
Renovation existing kitchen. Installation of new kitchen fixtures. No change of use, egress or occupancy under this application.
B08054111-I1
03/01/2023
Filed — Alteration
Renovation of existing Kitchen and Install new rear metal deck. New walls, cabinets and floor finishes. No change of use, egress or occupancy under this application.
B08054101-I1
01/17/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
DANNY TRUJILLO
01/17/2023
Special inspection requirement — Structural Steel - Details
DANNY TRUJILLO
01/17/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
DANNY TRUJILLO
01/09/2023
Special inspection requirement — Lighting in dwelling units
Nicolas Zapata
01/09/2023
Special inspection requirement — Masonry
Nicolas Zapata
01/09/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
DANNY TRUJILLO
01/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nicolas Zapata
01/09/2023
Special inspection requirement — Exterior lighting power
Nicolas Zapata
12/13/2022
Special inspection requirement — Final
KIRK MITCHELL
12/13/2022
Special inspection requirement — Final
DANNY TRUJILLO
01/11/2006
Violation issued (HPD, open)
C
12/13/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/02/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offAMOS & CLIVE CONSTRUCTION05/21/2024
DOB NOWGeneral ConstructionSigned-offDRAKES CARPENTRY & WOOD**01/02/2024
DOB NOWPlumbingSigned-offSAMUEL & SONS P & H INC12/27/2023
DOB NOWPlumbingSigned-offBENT MECHANICAL CORP11/16/2023
DOB NOWStructuralSigned-offBLUESKY CONST. & CONSULTI10/03/2023
DOB NOWGeneral ConstructionSigned-offBLUESKY CONST. & CONSULTI09/29/2023
BISPLISSUEDCODE MECHANICAL INC04/04/2022
BISOTISSUEDDOWNTOWN COMPLETE CONSTRUCTION09/18/2007
BISPLISSUEDBAY RIDGE MECHANICAL CORP02/22/1999
BISEQISSUEDNAGA CONSTRACTING01/13/1999
BIS—ISSUEDMAGA CONSTRACTING INC01/13/1999
BISEQISSUEDNAGA CONSTRACTING10/26/1998
BIS—ISSUEDMAGA CONSTRACTING INC10/05/1998
1 project · most recent 08/01/2024
Gas Water/Sanitary
FiledStatusContractorScope
08/01/2024Signed-offSAMUEL & SONS P & H INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
09/10/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/28/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/22/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
08/23/2024Fire-Resistant Penetrations and JointsNicolas Zapataspecial
07/22/2024Fire-Resistant Penetrations and JointsNicolas Zapataspecial
01/17/2023Structural Stability – Alterations of existing buildingsDANNY TRUJILLOspecial
01/17/2023Structural Steel - DetailsDANNY TRUJILLOspecial
01/17/2023Construction Operations Influencing Adjacent StructuresDANNY TRUJILLOspecial
01/09/2023Lighting in dwelling unitsNicolas Zapataenergy_progress
01/09/2023MasonryNicolas Zapataspecial
01/09/2023Structural Stability – Alterations of existing buildingsDANNY TRUJILLOspecial
01/09/2023Fire-Resistant Penetrations and JointsNicolas Zapataspecial
01/09/2023Exterior lighting powerNicolas Zapataenergy_progress
12/13/2022FinalKIRK MITCHELLprogress
12/13/2022FinalDANNY TRUJILLOprogress
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/27/2026B08054101-I1Request digital key ↗
08/27/2026B08054150-I1Request digital key ↗
08/24/2026B08054111-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
05/02/2022310016755Open ↗
04/04/2022310016755Open ↗
12/12/2007310016755Open ↗
▸BISWORK PERMIT APPLICATION2
04/04/2022310016755Open ↗
09/18/2007310016755Open ↗
▸Seals & Professional Certifications19
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026B08054111-I1Open ↗
08/29/2026B08054111-P2Open ↗
08/24/2026B08054150-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/27/2026B08054101-I1Open ↗
08/27/2026B08054150-I1Open ↗
08/24/2026B08054111-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026B08054150-I1Open ↗
08/23/2026B08054101-I1Open ↗
08/23/2026B08054101-I1Open ↗
▸BISPC FULL REPORT1
08/31/2007310016755Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/31/2007310016755Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/31/2007310016755Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/31/2007310016755Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
04/04/2022310016755Open ↗
▸Safety & Tenant Protection1
▸BIS* SHORING 27-10101
06/15/2022310016755Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/27/2026B08054101-I1Open ↗
08/27/2026B08054150-I1Open ↗
08/24/2026B08054111-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
08/31/2007310016755Open ↗
▸Inspections & Test Reports5
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
06/15/2022310016755Open ↗
▸BIS* WELDING 27-6161
06/15/2022310016755Open ↗
▸BIS* STRUCTURAL STABILITY 1 RCNY:16-011
06/15/2022310016755Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/15/2022310016755Open ↗
▸BIS* CONCRETE 27-6031
06/15/2022310016755Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/16/2022310016755Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
08/31/2007310016755Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
09/18/2007310016755Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/15/2022310016755Open ↗
▸Other Documents3
▸BIS* UNDERPINNING 27-7241
06/15/2022310016755Open ↗
▸BIS* * SUBGRADE 27-723,DIRC 15/711
06/15/2022310016755Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B08054150-I1Open ↗