← Back
Two stories - detached, small or mid-size
405 EAST 7 STREET
BROOKLYN · Kensington · BIN 3125549
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R5Zoning
1,825 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Two stories - detached, small or mid-size · 3,374 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof4p · 1 filing · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/19/2021$1.8M—— → —$1,008/sf building
12/10/2013$800K—Private party → Private party$438/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
UNISOLAR306/02/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CENTURION SOLAR ENERGYGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CENTURION SOLAR ENERGY LL9475306/02/2026
Building Lifecycle
All (17)Filed (3)Permit Issued (1)Signed Off (1)Violation (4)Special Inspection (8)
06/05/2026
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01212426-I1
06/02/2026
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01212426-P3
06/02/2026
Special inspection requirement — Air barrier - visual inspection
Andres Arias Londono
06/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Andres Arias Londono
06/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Andres Arias Londono
06/02/2026
Special inspection requirement — Final
Andres Arias Londono
02/05/2026
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01212426-P1
12/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Andres Arias Londono
12/31/2025
Special inspection requirement — Energy Code Compliance Inspections
Andres Arias Londono
12/31/2025
Special inspection requirement — Final
Andres Arias Londono
12/31/2025
Special inspection requirement — Air barrier - visual inspection
Andres Arias Londono
05/12/2025
Permit issued — Solar
B01212426-I1-SL
05/07/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01212426-I1
07/18/2019
Violation issued (ECB, closed)
Construction
08/15/2018
Violation issued (ECB, closed)
Construction
07/02/1998
Violation issued (ECB, closed)
Construction
07/02/1998
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY05/12/2025
BISOTISSUEDH 7 H BUILDING CONSULTANTS11/16/1998
1 project · most recent 11/25/2025
FiledStatusContractorScope
11/25/2025CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 06/02/2026
FiledStatusContractorScope
06/02/2026Signed-offCENTURION SOLAR ENERGY56 panels, 23.8 kw, 588.54 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/02/2026Air barrier - visual inspectionAndres Arias Londonoenergy_progress
06/02/2026Fire-Resistant Penetrations and JointsAndres Arias Londonospecial
06/02/2026Energy Code Compliance InspectionsAndres Arias Londonoprogress
06/02/2026FinalAndres Arias Londonoprogress
12/31/2025Fire-Resistant Penetrations and JointsAndres Arias Londonospecial
12/31/2025Energy Code Compliance InspectionsAndres Arias Londonoprogress
12/31/2025FinalAndres Arias Londonoprogress
12/31/2025Air barrier - visual inspectionAndres Arias Londonoenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026B01212426-P3Request digital key ↗
08/21/2026B01212426-P1Request digital key ↗
08/21/2026B01212426-I1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B01212426-P1Open ↗
09/01/2026B01212426-P1Open ↗
09/01/2026B01212426-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026B01212426-P3Open ↗
08/13/2026B01212426-I1Open ↗
08/13/2026B01212426-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01212426-P1Open ↗
08/27/2026B01212426-P3Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026B01212426-P3Open ↗
08/13/2026B01212426-P1Open ↗
08/13/2026B01212426-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01212426-I1Open ↗