← Back
BuildNYC
Over six families without stores
406 EAST 153RD STREET
BRONX · BIN 2130689
💬 Discuss this project
2023Year Built
4Stories
C1Building Class
R6Zoning
6,297 sfGross Floor Area
10Units
Rent Stabilized19 Active Violations ▸
Over six families without stores · Owner of record: HSK East 153 Street · 2,250 sf lot · 2.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof47p · 1 filing · 20 docs
Penthouse110p · 1 filing · 20 docs
Floor 4108p · 1 filing · 20 docs
Floor 3Unit 3A, Unit 3B110p · 1 filing · 20 docs
Floor 2105p · 1 filing · 20 docs
Floor 1125p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
Site & exteriorProposed heavy duty sidewalk shed5p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HSK East 153 Street203/22/2026
HSK Capital Group103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/28/2021$900K—MELROSE 153 LLC → HSK EAST 153 STREET LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Nikolai Katz Architect803/24/2026
AL Ffred Architecture603/27/2025
Zee Structural Engineering207/02/2024
Ashraf102/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Express Filing1803/21/2026
Empire Expediting1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Ace Maintenance USAGeneral Contractor607/08/2026
HSK ManagementGeneral Contractor607/08/2026
HSK ManagementScaffold303/21/2026
J & G Construction ServicesScaffold303/21/2026
Watermark PlumbingPlumbing207/08/2026
Ace Maintenance USAScaffold107/08/2026
Arco Plumbing and HeatingFire Protection107/08/2026
American Power Electric ConsElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF Services56161203/24/2026
IP Concrete Testing and I6252207/02/2024
AA Building & Inspection1519104/01/2022
Building Lifecycle
04/22/2026
Signed off — New Building
EARTH WORK, FOUNDATION AND STRUCTURAL SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #X00553697-I1
X00553697-S4
04/06/2026
Special inspection requirement — Lighting controls
FAHAD FATEH
04/06/2026
Special inspection requirement — Exterior lighting power
FAHAD FATEH
04/06/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
04/06/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
117 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWatermark Plumbing05/14/2025
DOB NOWSprinklersSigned-offArco Plumbing and Heating04/07/2025
DOB NOWGeneral ConstructionPermit IssuedAce Maintenance USA09/11/2024
DOB NOWMechanical SystemsSigned-offAce Maintenance USA05/31/2024
DOB NOWEarth WorkSigned-offAce Maintenance USA03/04/2024
DOB NOWGeneral ConstructionPermit IssuedAce Maintenance USA03/04/2024
DOB NOWPlumbingSigned-offWatermark Plumbing02/28/2024
DOB NOWConstruction FenceSigned-offAce Maintenance USA02/23/2024
DOB NOWSidewalk ShedSigned-offJ & G Construction Services02/08/2024
DOB NOWConstruction FenceSigned-offHSK Management05/12/2023
DOB NOWGeneral ConstructionPermit IssuedHSK Management05/11/2023
DOB NOWStructuralSigned-offHSK Management03/13/2023
DOB NOWGeneral ConstructionPermit IssuedHSK Management03/06/2023
DOB NOWGeneral ConstructionSigned-offHSK Management06/14/2022
1 project · most recent 03/24/2026
Heating Systems Ventilation Systems
FiledStatusContractorScope
03/24/2026Permit IssuedAce Maintenance USAHeating Systems, Ventilation Systems
1 project · most recent 03/24/2026
Sprinkler System
FiledStatusContractorScope
03/24/2026Signed-offArco Plumbing and HeatingSprinkler System
1 project · most recent 03/24/2026
Storm Water/Sanitary
FiledStatusContractorScope
03/24/2026Signed-offWatermark PlumbingStorm, Water/Sanitary
3 projects · most recent 04/21/2025
General Wiring
FiledStatusContractorScope
04/21/2025CompleteAmerican Power Electric ConsGeneral Wiring
02/08/2024CompleteRichard Neu—
05/19/2023CompleteSolas Electrical—
1 project · most recent 03/24/2026
Steel Concrete Masonry
FiledStatusContractorScope
03/24/2026Signed-offWatermark PlumbingSteel, Concrete, Masonry
1 project · most recent 03/24/2026
Fence
FiledStatusContractorScope
03/24/2026Signed-offWatermark PlumbingFence
1 project · most recent 03/24/2026
Earthwork
FiledStatusContractorScope
03/24/2026Signed-offWatermark PlumbingEarthwork
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
03/19/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/08/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/07/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
05/06/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/30/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/13/2025Fail-Final CND-Occupancy InspectionFailView ↗
08/23/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/18/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/18/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 149
DateRequirementInspectorRole
04/06/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/06/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
04/06/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
04/06/2026Maintenance informationFAHAD FATEHenergy_progress
04/06/2026Fenestration air leakageFAHAD FATEHenergy_progress
04/06/2026Lighting in dwelling unitsFAHAD FATEHenergy_progress
04/06/2026Exterior lighting powerFAHAD FATEHenergy_progress
04/06/2026Protection of exposed foundation insulationShahrish Shuvoenergy_progress
04/06/2026Interior lighting powerFAHAD FATEHenergy_progress
04/06/2026Lighting controlsFAHAD FATEHenergy_progress
04/06/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
04/06/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
04/06/2026Fenestration areasFAHAD FATEHenergy_progress
04/06/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
04/06/2026MeteringFAHAD FATEHenergy_progress
03/23/2026Lighting in dwelling unitsFAHAD FATEHenergy_progress
03/23/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
03/23/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
03/23/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
03/23/2026Protection of exposed foundation insulationShahrish Shuvoenergy_progress
03/23/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
03/23/2026Lighting controlsFAHAD FATEHenergy_progress
03/23/2026Interior lighting powerFAHAD FATEHenergy_progress
03/23/2026MeteringFAHAD FATEHenergy_progress
03/23/2026Fenestration areasFAHAD FATEHenergy_progress
Latest 25 of 149.
161 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account