← Back
All parking garages
406 MAC DONOUGH STREET
BROOKLYN · BIN 3047143
💬 Discuss this project
1916Year Built
1Stories
G1Building Class
R6BZoning
7,500 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
All parking garages · 7,500 sf lot · 1 FAR built · Flood zone X
Locations of Work
ElectricalPlumbingFire Protection
Roof3p · 1 filing · 18 docs
Bulkhead1p · 1 filing · 18 docs
Floor 61p · 1 filing · 18 docs
Floor 54p · 1 filing · 18 docs
Floor 44p · 1 filing · 18 docs
Floor 34p · 1 filing · 18 docs
Floor 24p · 1 filing · 18 docs
Floor 15p · 1 filing · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LE CAPITAL NYC509/01/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GEORGE CAMBOURAKIS208/25/2026
FLORINELA MURESAN308/11/2026
NIKOLA MARTINOVIC104/22/2026
STUDIOSC ARCHITECTURE PLLC102/06/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING203/21/2026
Building Lifecycle
All (83)Filed (7)Violation (2)Objection (44)Special Inspection (30)
09/09/2026
Objection raised — Structural
09/09/2026
Objection raised — Structural
09/09/2026
Objection raised — Other
09/09/2026
Objection raised — Admin
09/09/2026
Objection raised — Admin
09/09/2026
Objection raised — Admin
09/09/2026
Objection raised — Structural
09/08/2026
Objection raised — Other
09/08/2026
Objection raised — Other
08/25/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSE NEW VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 1-STORY FOR A NEW 5-STORY MULTIFAMILY BUILDING W/. GENERAL CONSTRUCTION WORKS AS PER PLAN. IT WILL BE UPGRADED TO IB CONSTRUCTION, & COMPLY WITH NEW BUILDING REQUIREMENTS. OBTAIN A NEW C OF O.
B01353337-S6
08/25/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSE NEW VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 1-STORY FOR A NEW 5-STORY MULTIFAMILY BUILDING W/. GENERAL CONSTRUCTION WORKS AS PER PLAN. IT WILL BE UPGRADED TO IB CONSTRUCTION, & COMPLY WITH NEW BUILDING REQUIREMENTS. OBTAIN A NEW C OF O.
B01353337-S5
08/25/2026
Objection raised — Energy
08/25/2026
Objection raised — Scope
08/25/2026
Objection raised — Other
08/25/2026
Objection raised — Other
08/25/2026
Objection raised — Energy
08/25/2026
Objection raised — Scope
08/25/2026
Objection raised — Admin
08/25/2026
Objection raised — Cost
08/25/2026
Objection raised — Zoning
08/25/2026
Objection raised — Cost
08/25/2026
Objection raised — Fire_Protection
08/25/2026
Objection raised — Scope
08/25/2026
Objection raised — Scope
08/25/2026
Objection raised — Inspections
08/25/2026
Objection raised — Scope
08/25/2026
Objection raised — Other
08/25/2026
Objection raised — Inspections
08/24/2026
Special inspection requirement — Subgrade Inspections
08/24/2026
Special inspection requirement — Footing and Foundation
08/24/2026
Special inspection requirement — Concrete - Cast-In-Place
08/24/2026
Special inspection requirement — Concrete - Cast-In-Place
08/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/24/2026
Special inspection requirement — Final
08/24/2026
Special inspection requirement — Final
08/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/24/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
08/11/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSE NEW VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 1-STORY FOR A NEW 5-STORY MULTIFAMILY BUILDING W/. GENERAL CONSTRUCTION WORKS AS PER PLAN. IT WILL BE UPGRADED TO IB CONSTRUCTION, & COMPLY WITH NEW BUILDING REQUIREMENTS. OBTAIN A NEW C OF O.
B01353337-S2
08/11/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSE NEW VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 1-STORY FOR A NEW 5-STORY MULTIFAMILY BUILDING W/. GENERAL CONSTRUCTION WORKS AS PER PLAN. IT WILL BE UPGRADED TO IB CONSTRUCTION, & COMPLY WITH NEW BUILDING REQUIREMENTS. OBTAIN A NEW C OF O.
B01353337-S3
07/29/2026
Objection raised — Scope
07/29/2026
Objection raised — Structural
07/29/2026
Objection raised — Fire_Protection
07/29/2026
Objection raised — Admin
07/29/2026
Objection raised — Scope
07/17/2026
Objection resolved — Resolved
07/15/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSE NEW VERTICAL & HORIZONTAL ENLARGEMENT OF EXISTING 1-STORY FOR A NEW 5-STORY MULTIFAMILY BUILDING W/. GENERAL CONSTRUCTION WORKS AS PER PLAN. IT WILL BE UPGRADED TO IB CONSTRUCTION, & COMPLY WITH NEW BUILDING REQUIREMENTS. OBTAIN A NEW C OF O.
B01353337-S4
06/25/2026
Objection raised — Zoning
06/25/2026
Objection raised — Zoning
06/25/2026
Objection raised — Other
06/25/2026
Objection raised — Zoning
06/25/2026
Objection raised — Cost
06/10/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/09/2026
Special inspection requirement — Interior lighting power
06/09/2026
Special inspection requirement — Post-installed Anchors
06/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/09/2026
Special inspection requirement — Post-installed Anchors
06/09/2026
Special inspection requirement — Energy Code Compliance Inspections
06/09/2026
Special inspection requirement — Shutoff dampers
06/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/09/2026
Special inspection requirement — Post-installed Anchors
Latest 60 of 83 events.
Nothing on file for this building.
1 project · most recent 08/25/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ZRUN024GSS0 27,000 BTU · Vrf Outdoor ×12
ZRUM048GSS0 54,000 BTU · Vrf Outdoor ×2
Captiveaire CAS-HVAC1-E.402-15-7.5T-ERV 71,600 BTU · Erv ×1
Ventilation
Greenheck BSD-160 3,250 CFM · Exhaust Fan ×1
BSQ-160 3,550 CFM · Exhaust Fan ×1
G-095-VG 300 CFM · Exhaust Fan ×1
SQ-98-VG 250 CFM · Exhaust Fan ×1
USF-12-B7 950 CFM · Exhaust Fan ×1
1 project · most recent 08/25/2026
Sprinkler System
FiledStatusContractorScope
08/25/2026——Sprinkler System
1 project · most recent 08/25/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/25/2026——Storm, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
08/24/2026Subgrade Inspections—special
08/24/2026Footing and Foundation—progress
08/24/2026Concrete - Cast-In-Place—special
08/24/2026Concrete - Cast-In-Place—special
08/24/2026Structural Stability – Alterations of existing buildings—special
08/24/2026Final—progress
08/24/2026Final—progress
08/24/2026Structural Stability – Alterations of existing buildings—special
08/24/2026Subsurface Conditions – Fill Placement & In-Place Density—special
06/10/2026Structural Stability – Alterations of existing buildings—special
06/09/2026Interior lighting power—energy_progress
06/09/2026Post-installed Anchors—special
06/09/2026Fire-Resistant Penetrations and Joints—special
06/09/2026Post-installed Anchors—special
06/09/2026Energy Code Compliance Inspections—progress
06/09/2026Shutoff dampers—energy_progress
06/09/2026Fire-Resistant Penetrations and Joints—special
06/09/2026Post-installed Anchors—special
06/09/2026Maintenance information—energy_progress
06/09/2026HVAC-R and service water heating system controls—energy_progress
06/09/2026HVAC-R and service water heating equipment—energy_progress
06/09/2026HVAC-R and service water piping design and insulation—energy_progress
06/09/2026Lighting controls—energy_progress
06/09/2026HVAC-R and service water piping design and insulation—energy_progress
06/09/2026Electrical motors and elevators—energy_progress
Latest 25 of 38.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/17/2026B01353337-S2Request digital key ↗
08/17/2026B01353337-S1Request digital key ↗
08/17/2026B01353337-S3Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01353337-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026B01353337-S1Open ↗
08/17/2026B01353337-I1Open ↗
08/17/2026B01353337-S4Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026B01353337-S2Open ↗
08/17/2026B01353337-S3Open ↗
08/14/2026B01353337-I1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026B01353337-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01353337-I1Open ↗
▸DOB NOWProperty Ownership Certification1