← Back
Three families
4064 BARNES AVENUE
BRONX · BIN 2064028
💬 Discuss this project
1910Year Built
3Stories
C0Building Class
R4Zoning
3,180 sfGross Floor Area
3Units
Rent Stabilized13 Open Violations ▸
Three families · 2,205 sf lot · 1.44 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction27p · 1 filing · 20 docs
Floor 2Under Construction27p · 1 filing · 20 docs
Floor 1Under Construction27p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BADALY ENGINEERING PLLC401/14/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WEBB DEVELOPMENT SVC CORPGeneral Contractor606/28/2026
MAMC CONSULTING REPS LLCGeneral Contractor107/08/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BADALY ARCHITECT PLLC7137301/14/2025
Building Lifecycle
All (120)Filed (4)Permit Issued (6)Violation (57)Inspection (5)Objection (26)Special Inspection (22)
08/21/2026
Inspection — Pass-Final SD - Up to 9 Requested Floors
Pass
View inspection ↗
06/22/2026
Permit issued — General Construction
X01044782-I1-GC
04/29/2026
Violation issued (HPD, open)
A
11/18/2025
Violation issued (HPD, closed)
I
08/14/2025
Permit issued — General Construction
X01044782-I1-GC
06/04/2025
Violation issued (HPD, open)
A
02/05/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
01/27/2025
Special inspection requirement — Energy Code Compliance Inspections
SHAHIN BADALY
01/27/2025
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
01/27/2025
Special inspection requirement — Maintenance information
SHAHIN BADALY
01/27/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
01/27/2025
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
01/23/2025
Permit issued — Mechanical Systems
X01044782-S2-MS
01/21/2025
Objection resolved — Addressed
01/17/2025
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
01/15/2025
Objection raised — Other
01/14/2025
Filed — Alteration
NEW MINI-SPLIT MECHANICAL SYSTEM
X01044782-S2
01/09/2025
Filed — Alteration
NEW MINI-SPLIT MECHANICAL SYSTEM
X01044782-P1
01/09/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
01/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
01/09/2025
Special inspection requirement — Permanent certificate
SHAHIN BADALY
01/09/2025
Special inspection requirement — Duct leakage testing, insulation and design
SHAHIN BADALY
01/09/2025
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
01/09/2025
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
01/09/2025
Special inspection requirement — Maintenance information
SHAHIN BADALY
01/09/2025
Special inspection requirement — Ventilation and air distribution system
SHAHIN BADALY
01/03/2025
Special inspection requirement — Final
MOHAMMAD BADALY
01/03/2025
Special inspection requirement — Energy Code Compliance Inspections
SHAHIN BADALY
01/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHIN BADALY
01/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
SHAHIN BADALY
01/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
SHAHIN BADALY
01/03/2025
Special inspection requirement — Maintenance information
SHAHIN BADALY
01/03/2025
Special inspection requirement — Mechanical Systems
SHAHIN BADALY
01/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHIN BADALY
12/06/2024
Permit issued — Plumbing
X01044782-S1-PL
11/29/2024
Permit issued — General Construction
X01044782-I1-GC
11/25/2024
Violation issued (HPD, closed)
I
10/21/2024
Filed — Alteration
NEW MINI-SPLIT MECHANICAL SYSTEM
X01044782-S1
09/24/2024
Permit issued — General Construction
X01044782-I1-GC
07/22/2024
Objection raised — Fire_Protection
07/22/2024
Objection resolved — Addressed
06/21/2024
Objection raised — Admin
06/21/2024
Objection resolved — Addressed
06/21/2024
Objection raised — Other
06/21/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Other
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Fire_Protection
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Scope
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Scope
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Accessibility
05/29/2024
Objection resolved — Addressed
05/29/2024
Objection raised — Accessibility
05/29/2024
Objection resolved — Addressed
Latest 60 of 120 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedWEBB DEVELOPMENT SVC CORP06/22/2026
DOB NOWGeneral ConstructionPermit IssuedWEBB DEVELOPMENT SVC CORP08/14/2025
DOB NOWMechanical SystemsPermit IssuedMAMC CONSULTING REPS LLC01/23/2025
DOB NOWPlumbingPermit IssuedROCK E SMALL PLBG&HTG INC12/06/2024
DOB NOWGeneral ConstructionPermit IssuedWEBB DEVELOPMENT SVC CORP11/29/2024
DOB NOWGeneral ConstructionPermit IssuedWEBB DEVELOPMENT SVC CORP09/24/2024
1 project · most recent 01/14/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/14/2025Permit IssuedWEBB DEVELOPMENT SVC CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin DAIKIN FTXS09LVJU 12,000 BTU · Split System ×6
DAIKIN FTXS15LVJU 18,000 BTU · Split System ×3
Ventilation
Panasonic PANASONIC VTX400 208 CFM · Exhaust Fan ×3
Daikin ×3
1 project · most recent 01/14/2025
Gas Water/Sanitary
FiledStatusContractorScope
01/14/2025Permit IssuedROCK E SMALL PLBG&HTG INCGas, Water/Sanitary
1 project · most recent 11/10/2025
FiledStatusContractorScope
11/10/2025Permit IssuedM & M CONTROL WIRING &4 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/21/2026Pass-Final SD - Up to 9 Requested FloorsPassView ↗
02/05/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/17/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
01/27/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
01/27/2025Energy Code Compliance InspectionsSHAHIN BADALYprogress
01/27/2025HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
01/27/2025Maintenance informationSHAHIN BADALYenergy_progress
01/27/2025HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
01/27/2025HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
01/09/2025HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
01/09/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
01/09/2025Permanent certificateSHAHIN BADALYenergy_progress
01/09/2025Duct leakage testing, insulation and designSHAHIN BADALYenergy_progress
01/09/2025HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
01/09/2025HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
01/09/2025Maintenance informationSHAHIN BADALYenergy_progress
01/09/2025Ventilation and air distribution systemSHAHIN BADALYenergy_progress
01/03/2025FinalMOHAMMAD BADALYprogress
01/03/2025Energy Code Compliance InspectionsSHAHIN BADALYprogress
01/03/2025HVAC-R and service water piping design and insulationSHAHIN BADALYenergy_progress
01/03/2025HVAC-R and service water heating equipmentSHAHIN BADALYenergy_progress
01/03/2025HVAC-R and service water heating system controlsSHAHIN BADALYenergy_progress
01/03/2025Maintenance informationSHAHIN BADALYenergy_progress
01/03/2025Mechanical SystemsSHAHIN BADALYspecial
01/03/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026X01044782-P1Request digital key ↗
08/20/2026X01044782-S1Request digital key ↗
08/20/2026X01044782-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature12
08/28/2026X01044782-S1Open ↗
08/28/2026X01044782-S1Open ↗
08/24/2026X01044782-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026X01044782-S1Open ↗
08/13/2026X01044782-S2Open ↗
08/13/2026X01044782-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026X01044782-S1Open ↗
08/24/2026X01044782-S2Open ↗
08/24/2026X01044782-S2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026X01044782-S1Open ↗
08/13/2026X01044782-I1Open ↗
08/13/2026X01044782-P1Open ↗
Showing 3 of 4 on file for this type