HPD09/19/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 57, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD09/19/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 57, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD09/19/2026§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 5th STORY
HPD09/19/2026§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 57, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
ECB01/27/2026CLASS 2 ITEMS: IN-CAR COMMUNICATION INOPERATIVE. PROVIDE THE MACHINE ROOM DOOR TO BE SELF CLOSING AND LOCKING. CLEAN OIL FROM HOSIT MACHINE AND BED PLATE.$625 due
ECB01/08/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER . NOTED UPON INSPECTION A/C BRACKETS NOT INSTALLED ON 1 ST FL AT EXP # 2 EAST & 5 FL AT EXP # 2 WEST. AS WELL AS EXP #1 SOUTH 2ND FL & EXP #1 NORTH SECOND F$1K due
ECB08/06/2025CLASS 2:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,EMERGENCY PHONE IN ELEVATOR INOPERATIVE,REPAIR/CONNECT PHONE TO 24HRS EMERGENC$3K due
HPD06/11/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 32, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/29/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT 2nd CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st CLOSET FROM WEST AT NORTH WALL DOOR FRAME, 1st CLOSET FROM WEST AT NORTH WALL DOOR, 2nd CLOSET FROM WEST AT NORTH WALL DOOR IN THE FOYER LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD05/29/2025§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL, 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE KITCHEN LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD05/29/2025§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AND CLEANABLE, POSITIVE LEAD-BASED PAINT IN AN APARTMENT WITH A CHILD UNDER SIX LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD03/21/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH
HPD03/21/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH
HPD03/09/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD01/09/2024§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMP. EXCEEDING 130 DEGREES AT FIXTURES KITCHEN AND IN THE BATHROOM LOCATED AT APT 4, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''NORTH''
HPD08/03/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE FIRE RETARDANT DOOR IN THE ENTRANCE LOCATED AT APT 67, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''South''
HPD05/10/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH, WEST, SOUTH WALLS AND THE CEILING IN THE BATHROOM LOCATED AT APT 63, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/29/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 66, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/29/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 66, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
DOB08/22/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/22/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/22/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB05/20/2019FAILURE TO PERFORM CATEGORY 5 INSPECTION
DOB02/06/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/19/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/19/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/19/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB05/13/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB10/01/2012VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
DOB03/15/2004V-DOB VIOLATION - ACTIVE
ECB02/05/202559-BB-5=BRAKE MAINTENANCE TAG EXPIRED MUST REFORM AND FILE ON TAG BY CONTROLLER WITH DATE OF TEST AND ON MCP.Nothing owed — awaiting certificate of correction
ECB08/24/2023FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR NOV 38234148P. REMEDY: FILE CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB07/03/2023AT TIME OF INSPECTION I OBSERVED VIOLATION NUMBERS 39000781P, 35204218P, 35204216L, 39003155L, 39003156N, 39003157P & 35204217N HAVE FAILED TO MEET THE COMMISSIONERS ORDERS OF COMPLIANCE., COMPLY WITH COMMISSIONothing owed — awaiting certificate of correction
ECB06/03/2019ON 11-17-18 @ APPROX 3:30 PM I OBSERVED AN ACTIVE GAS METER HAVING NEW GAS PIPING AND GAS FITTINGSINSTALLED FOR 3 COMMERCIAL GAS DRYERS WITHOUT ANY DOB GAS INSPECTIONS AND GAS AUTHORIZATION ONFILE UNDER DOB RECNothing owed — awaiting certificate of correction
ECB06/03/2019ON 11-17-18 @ APPROX 3:30 PM I OBSERVED 3 COMMERCIAL GAS DRYERS INSTALLED WITH FLEXIBLE GAS HOSE,WHICH IS NOT CODE COMPLIANT., REPAIR AND/REPLACE; <Nothing owed — awaiting certificate of correction
ECB11/17/2018ON 11-17-18 @ APPROX 3:30 PM I OBSERVED IN THE BASEMENT LEVEL 3 COMMERCIAL GAS DRYERS INSTALLED WITHOUT ANY FIRE SPRINKLER PROTECTION INSTALLED., <Nothing owed — awaiting certificate of correction
ECB11/17/2018ON 11-17-18 @ APPROX 3:30 PM I OBSERVED NEW GAS PIPING AND GAS FITTINGS INSTALLED FOR 3 COMMERCIALGAS DRYERS WITHOUT ANY GAS TEST INSPECTION CONDUCTED ON FILE UNDER DOB RECORDS., PERFORM TEST; <Nothing owed — awaiting certificate of correction
ECB01/20/2017FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. LACK OF A SYSTEM OFAUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2;27-954. AT THE TIME OF MY INSPECTION @ 5:15PM ON ABOVE DATE AT THE ABOVE ADDRESS I OBSERVEDNothing owed — awaiting certificate of correction
ECB01/20/2017GAS BEING SUPPLIED TO BLDG W/O INSPECTION OR CERTIFICATION BY DOB. AT THE TIME OF MY INSPECTION @ 5:10PM ON ABOVE DATE AT THE ABOVE ADDRESS I OBSERVED IN THE CELLAR NEW GAS PIPING COMING FROM THE METER LABELEDNothing owed — awaiting certificate of correction
ECB01/20/2017FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT THE TIME OF MY INSPECTION @ 5:15PM ON ABOVE DATE AT THE ABOVE ADDRESS I OBSERVED IN THE CELLAR INSIDE THE LAUNDRY ROOM 3 COMMERCIAL DRYER W/FLEX HOSE. THESENothing owed — awaiting certificate of correction
ECB02/20/20153I10,2B10,68B7,42G11,15I11. 3 PHONE NOT WORKING; 2-ALARM BELL NOT WORKING; 42-REPLACE JUMPED FUSE.Nothing owed — awaiting certificate of correction