← Back
Elevator apt, fireproof with stores
Harlem River Ninth Avenue Condominium
408 WEST 207 STREET · BIN 1091691
💬 Discuss this project
2023Year Built
17Stories
D6Building Class
—Zoning
218,848 sfGross Floor Area
225Units
Rent Stabilized0 Open Violations
Elevator apt, fireproof with stores · Owner of record: HARLEM RIVER NINTH AVENUE DEVELOPMENT LL C · 19,984 sf lot · 10.95 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 2 docs
Floor 16Under Construction82p · 1 filing · 20 docs
Floor 15Under Construction82p · 1 filing · 20 docs
Floor 14Under Construction82p · 1 filing · 20 docs
Floor 13Under Construction82p · 1 filing · 20 docs
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4Under Construction82p · 1 filing · 20 docs
Floor 3Under Construction82p · 1 filing · 20 docs
Floor 2Under Construction83p · 1 filing · 20 docs
Floor 1Under Construction82p · 1 filing · 20 docs
CellarUnder Construction93p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLATINUM SERVICES NY1507/08/2026
VIK XS SERVICES1507/08/2026
ALBA SERVICES407/08/2026
ROCK GROUP NY1007/08/2026
URBAN ATELIER GROUP603/22/2026
HARLEM RIVER NINTH AVENUE DEVELOPMENT LL C203/22/2026
PARHMARK STORES INC103/22/2026
PATHMARK STORES INC PROPA103/22/2026
CHATSWORTH BUILDERS203/22/2026
L M DEVELOPMENT PARTNERS103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/06/2021$7.2M—Private party → HARLEM RIVER NINTH AVENUE DEVELOPMENT LLC— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHATSWORTH BUILDERS LLCGeneral Contractor4507/08/2026
ROCK GROUP NY CORPGeneral Contractor1107/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor1007/08/2026
4 BROTHERS & SONS FENCEGeneral Contractor1007/08/2026
VIK XS SERVICES INCGeneral Contractor807/08/2026
RNC INDUSTRIES LLCGeneral Contractor707/08/2026
G.N.T. MECHANICAL LLCPlumbing607/08/2026
URBAN ATELIER GROUP LLCGeneral Contractor603/21/2026
G.N.T. MECHANICAL LLCFire Protection607/08/2026
LANGAN ENG ENV SUR L A GEO DPCGeneral Contractor203/22/2026
AMBER LITE ELECTRIC CORP.Electrical203/22/2026
HAAS INCORPORATEDGeneral Contractor107/08/2026
ALBA SERVICES INCGeneral Contractor107/08/2026
GLO ELECTRIC LLCElectrical103/22/2026
CHAMP PLUMBING & HTG CORPPlumbing107/08/2026
DIFAZIO ELECTRIC NY, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOMANI INSPECTION SERVICE8432011/20/2025
DESIMONE CONSULTING ENGIN5942211/10/2021
GEODESIGN, INC., P.C.627111/09/2021
Building Lifecycle
All (279)Filed (42)Permit Issued (66)Signed Off (24)Violation (21)Inspection (13)Objection (80)Special Inspection (30)Tax Incentive (3)
06/16/2026
421-a(16) construction completed
05/11/2026
Violation issued (HPD, closed)
A
01/20/2026
Permit issued — General Construction
M00599489-I1-GC
12/19/2025
Special inspection requirement — Protection of exposed foundation insulation
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Insulation placement and R values
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Air barrier continuity plan testing
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Vestibules
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Energy Code Compliance Inspections
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Fenestration areas
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Fenestration air leakage
JOHN MCMONAGLE
12/19/2025
Special inspection requirement — Air barrier - visual inspection
JOHN MCMONAGLE
12/11/2025
Objection resolved — Addressed
12/01/2025
Objection raised — Admin
11/20/2025
Filed — New Building
New 17 story building.
M00599489-B2
11/19/2025
Special inspection requirement — Fenestration areas
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Protection of exposed foundation insulation
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Air barrier - visual inspection
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Insulation placement and R values
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Air barrier continuity plan testing
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Vestibules
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Fenestration air leakage
JOHN MCMONAGLE
11/19/2025
Special inspection requirement — Energy Code Compliance Inspections
JOHN MCMONAGLE
11/06/2025
Signed off — New Building
New 17 story building.
M00599489-S6
11/06/2025
Signed off — New Building
New 17 story building.
M00599489-S5
10/31/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/29/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/14/2025
Permit issued — General Construction
M00599489-I1-GC
10/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Air barrier - visual inspection
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Energy Code Compliance Inspections
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Fenestration areas
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Air barrier continuity plan testing
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Protection of exposed foundation insulation
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Vestibules
JOHN MCMONAGLE
10/07/2025
Special inspection requirement — Fire-Resistance Rated Construction
JOHN MCMONAGLE
10/03/2025
Filed — New Building
New 17 story building.
M00599489-B1
09/23/2025
Signed off — New Building
New 17 story building.
M00599489-S8
09/17/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
09/02/2025
Signed off — Alteration
Supported Scaffold Installation as per plans filed herewith. No change in use, egress or occupancy
M00593706-S1
09/02/2025
Signed off — Alteration
Supported Scaffold Installation as per plans filed herewith. No change in use, egress or occupancy
M00593706-S2
07/18/2025
Signed off — Alteration
Installation of a temporary construction fence per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00867924-I1
06/27/2025
Signed off — Alteration
Supported Scaffold Installation as per plans filed herewith. No change in use, egress or occupancy
M00593706-S3
06/26/2025
Signed off — Alteration
CONSTRUCTION FENCE AS PER DRAWINGS DURING NB CONST (M00599489), FILED SEP. FENCE SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY.
M00982216-I1
06/24/2025
Signed off — Alteration
INSTALLATION OF 6000 LB DUAL CAR PERSONNEL/MATERIAL HOIST AS PER PLANS DURING CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00886980-I1
06/20/2025
Signed off — New Building
New 17 story building.
M00599489-S4
06/13/2025
Signed off — Alteration
INSTALLATION AND USE OF TEMPORARY CONCRETE PLACING BOOM AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00815900-I1
06/13/2025
Signed off — Alteration
M00918886-I1
06/13/2025
Signed off — Alteration
M00947679-I1
06/13/2025
Signed off — Alteration
INSTALLATION AND USE OF TEMPORARY CLIMBING PLATFORMS AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M08028708-I1
06/13/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/03/2025
Signed off — New Building
New 17 story building.
M00599489-S1
06/03/2025
Signed off — New Building
New 17 story building.
M00599489-S2
06/03/2025
Signed off — New Building
New 17 story building.
M00599489-S3
05/30/2025
Permit issued — Protection and Mechanical Methods
M00593706-S1-PMM
Latest 60 of 279 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedCHATSWORTH BUILDERS LLC01/20/2026
DOB NOWGeneral ConstructionPermit IssuedCHATSWORTH BUILDERS LLC10/14/2025
DOB NOWProtection and Mechanical MethodsSigned-offVIK XS SERVICES INC05/30/2025
DOB NOWConstruction FenceSigned-offPLATINUM SERVICES NY LLC05/12/2025
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE04/25/2025
DOB NOWSidewalk ShedSigned-offROCK GROUP NY CORP03/05/2025
DOB NOWCurb CutSigned-offCHATSWORTH BUILDERS LLC03/04/2025
DOB NOWBoiler EquipmentSigned-offCHAMP PLUMBING & HTG CORP02/20/2025
DOB NOWGeneral ConstructionPermit IssuedCHATSWORTH BUILDERS LLC02/06/2025
DOB NOWStructuralSigned-offCHATSWORTH BUILDERS LLC02/06/2025
DOB NOWProtection and Mechanical MethodsSigned-offVIK XS SERVICES INC01/09/2025
DOB NOWStandpipeSigned-offG.N.T. MECHANICAL LLC01/07/2025
DOB NOWSprinklersSigned-offG.N.T. MECHANICAL LLC12/19/2024
DOB NOWPlumbingSigned-offG.N.T. MECHANICAL LLC12/19/2024
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE12/18/2024
DOB NOWStructuralSigned-offCHATSWORTH BUILDERS LLC11/20/2024
DOB NOWFoundationSigned-offCHATSWORTH BUILDERS LLC11/19/2024
DOB NOWGeneral ConstructionPermit IssuedCHATSWORTH BUILDERS LLC11/19/2024
DOB NOWStandpipeSigned-offG.N.T. MECHANICAL LLC10/01/2024
DOB NOWProtection and Mechanical MethodsSigned-offVIK XS SERVICES INC09/11/2024
DOB NOWConstruction FenceSigned-offPLATINUM SERVICES NY LLC05/16/2024
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE05/09/2024
DOB NOWProtection and Mechanical MethodsSigned-offROCK GROUP NY CORP03/11/2024
DOB NOWSidewalk ShedSigned-offROCK GROUP NY CORP03/07/2024
DOB NOWProtection and Mechanical MethodsSigned-offPLATINUM SERVICES NY LLC03/06/2024
DOB NOWFoundationSigned-offCHATSWORTH BUILDERS LLC02/08/2024
DOB NOWStructuralSigned-offCHATSWORTH BUILDERS LLC02/05/2024
DOB NOWGeneral ConstructionPermit IssuedCHATSWORTH BUILDERS LLC01/30/2024
DOB NOWSprinklersSigned-offG.N.T. MECHANICAL LLC01/18/2024
DOB NOWStandpipeSigned-offG.N.T. MECHANICAL LLC01/18/2024
DOB NOWProtection and Mechanical MethodsSigned-offVIK XS SERVICES INC01/12/2024
DOB NOWPlumbingSigned-offG.N.T. MECHANICAL LLC01/11/2024
DOB NOWConstruction FenceSigned-off4 BROTHERS SONS FENCE12/28/2023
DOB NOWFoundationSigned-offCHATSWORTH BUILDERS LLC11/14/2023
DOB NOWStructuralSigned-offCHATSWORTH BUILDERS LLC11/13/2023
DOB NOWStandpipeSigned-offG.N.T. MECHANICAL LLC10/24/2023
DOB NOWProtection and Mechanical MethodsSigned-offRNC INDUSTRIES LLC10/13/2023
DOB NOWProtection and Mechanical MethodsSigned-offRNC INDUSTRIES LLC09/18/2023
DOB NOWSupported ScaffoldSigned-offVIK XS SERVICES INC09/12/2023
DOB NOWProtection and Mechanical MethodsSigned-offVIK XS SERVICES INC09/12/2023
+ 10 more permits on file
1 project · most recent 11/20/2025
Air Conditioning Systems Associated Ducts and Piping Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/20/2025Permit IssuedCHATSWORTH BUILDERS LLCAir Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Ice Air RSXC09 11,000 BTU · Ptac ×771
RSXC13 12,000 BTU · Ptac ×378
RSXC18 14,000 BTU · Ptac ×300
Samsung AM024ANHDCH/AA 22,900 BTU · Vrf Indoor ×6
AM030ANHDCH/AA 28,700 BTU · Vrf Indoor ×6
AM032MNQDCH/AA 29,100 BTU · Vrf Indoor ×4
AM048ANHDCH/AA 46,700 BTU · Vrf Indoor ×6
AM060MXMDCH/AA 58,300 BTU · Vrf Outdoor ×4
AM012ANMDCH/AA 11,700 BTU · Vrf Indoor ×3
AM030TNZDCH/AA 28,700 BTU · Vrf Indoor ×3
AM120BXVGJH/AA 105,200 BTU · Vrf Outdoor ×3
AM144BXVGJH/AA 131,900 BTU · Vrf Outdoor ×3
AM030BN4PCH/AA 29,100 BTU · Vrf Indoor ×2
AM048TXMDCH/AA 58,300 BTU · Vrf Outdoor ×2
Aermec NYBI0500F 28 tons · Chiller ×10
NYBI500 28 tons · Chiller ×5
Dunham-Bush SCS3H-50mm TTB-AH012-PF 31,200 BTU · Ahu ×3
Heating
Thermolec n/a 20 kW · Electric Heater ×2
Stelpro N/A 5 kW · Electric Heater ×1
Ventilation
Aaon RN-016-3-0-E609-12A 7,020 CFM · Erv ×4
RN-016-3-0-H609-12A 303,280 BTU · Rooftop Unit ×6
RN-030-3-0-E609-000 303,280 BTU · Erv ×2
Ducts & Piping
N/A n/a Ductwork ×3
1 project · most recent 11/20/2025
Sprinkler System
FiledStatusContractorScope
11/20/2025Signed-offG.N.T. MECHANICAL LLCSprinkler System
1 project · most recent 11/20/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
11/20/2025Signed-offCHAMP PLUMBING & HTG CORPGas, Storm, Water/Sanitary
8 projects · most recent 08/21/2025
General Wiring Lighting HVAC Wiring Boiler Controls
FiledStatusContractorScope
08/21/2025CompleteDIFAZIO ELECTRIC NY, INCGeneral Wiring
11/15/2023CancelledDIFAZIO ELECTRIC NY, INCGeneral Wiring
09/27/2023CompleteGLO ELECTRIC LLCGeneral Wiring, Lighting, HVAC Wiring, Boiler Controls
06/15/2023CompleteILLUMINOUS ELECTRIC CORP.—
04/18/2023CompleteILLUMINOUS ELECTRIC CORP.General Wiring
01/05/2023CompleteAMBER LITE ELECTRIC CORP.1 meters, 1 new_meters
12/30/2022CompleteAMBER LITE ELECTRIC CORP.—
07/12/2022CancelledAMBER LITE ELECTRIC CORP.1 meters, 1 new_meters
1 project · most recent 11/20/2025
Concrete
FiledStatusContractorScope
11/20/2025Permit IssuedCHATSWORTH BUILDERS LLCConcrete
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
10/31/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/29/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/17/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
06/13/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/03/2025Pass-Final Boiler Equipment InspectionPassView ↗
01/06/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/18/2023Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
09/18/2023Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
06/29/2023Fail-Final PL - UndergroundFailView ↗
06/07/2023Pass-Final PL - UndergroundPassView ↗
05/12/2023Pass-Final PL - UndergroundPassView ↗
04/24/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 149
DateRequirementInspectorRole
12/19/2025Insulation placement and R valuesJOHN MCMONAGLEenergy_progress
12/19/2025Fenestration areasJOHN MCMONAGLEenergy_progress
12/19/2025Fire-Resistance Rated ConstructionJOHN MCMONAGLEprogress
12/19/2025Energy Code Compliance InspectionsJOHN MCMONAGLEprogress
12/19/2025Protection of exposed foundation insulationJOHN MCMONAGLEenergy_progress
12/19/2025Air barrier - visual inspectionJOHN MCMONAGLEenergy_progress
12/19/2025Fenestration and door U-factor and product ratingsJOHN MCMONAGLEenergy_progress
12/19/2025Fire-Resistant Penetrations and JointsJOHN MCMONAGLEspecial
12/19/2025VestibulesJOHN MCMONAGLEenergy_progress
12/19/2025Fenestration air leakageJOHN MCMONAGLEenergy_progress
12/19/2025Air barrier continuity plan testingJOHN MCMONAGLEenergy_progress
11/19/2025Protection of exposed foundation insulationJOHN MCMONAGLEenergy_progress
11/19/2025Fire-Resistant Penetrations and JointsJOHN MCMONAGLEspecial
11/19/2025Fenestration areasJOHN MCMONAGLEenergy_progress
11/19/2025Fenestration air leakageJOHN MCMONAGLEenergy_progress
11/19/2025Fenestration and door U-factor and product ratingsJOHN MCMONAGLEenergy_progress
11/19/2025Air barrier continuity plan testingJOHN MCMONAGLEenergy_progress
11/19/2025Air barrier - visual inspectionJOHN MCMONAGLEenergy_progress
11/19/2025Energy Code Compliance InspectionsJOHN MCMONAGLEprogress
11/19/2025Fire-Resistance Rated ConstructionJOHN MCMONAGLEprogress
11/19/2025VestibulesJOHN MCMONAGLEenergy_progress
11/19/2025Insulation placement and R valuesJOHN MCMONAGLEenergy_progress
10/07/2025Fire-Resistant Penetrations and JointsJOHN MCMONAGLEspecial
10/07/2025Energy Code Compliance InspectionsJOHN MCMONAGLEprogress
10/07/2025Fire-Resistance Rated ConstructionJOHN MCMONAGLEprogress
Latest 25 of 149.
▾Documents — 305 on file (BIS + DOB NOW)
▸Plans & Drawings43
▸DOB NOWPlans/Sketch43
09/02/2026M00726260-I1Request digital key ↗
09/02/2026M00748027-I1Request digital key ↗
08/31/2026M00867924-I1Request digital key ↗
Showing 3 of 43 on file for this type
▸Applications & Permits12
▸DOB NOWHPD - Permit Notice6
08/13/2026M00599489-I1Open ↗
08/13/2026M00599489-B1Open ↗
08/13/2026M00599489-P1Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
10/01/2024141006818Open ↗
09/11/2024141006818Open ↗
01/25/2022141006818Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation2
06/29/2022141006818Open ↗
01/25/2022141006818Open ↗
▸BISBPP-DOT: SIDEWALK/CURB/ROAD WORK PERMITS1
02/24/2026141006818Open ↗
▸Zoning, Tax Lot & Property Records53
▸DOB NOWRestrictive Declaration/Easement 124
08/13/2026M00599489-B2Open ↗
08/13/2026M00599489-S6Open ↗
08/13/2026M00599489-S1Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWZoning Exhibit form (1-5)8
08/13/2026M00599489-A2Open ↗
08/13/2026M00599489-A1Open ↗
08/13/2026M00599489-A7Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram8
08/13/2026M00599489-P1Open ↗
Showing 1 of 8 on file for this type
▸DOB NOWRestrictive Declaration/Easement 24
08/13/2026M00599489-B2Open ↗
08/13/2026M00599489-A7Open ↗
08/13/2026M00599489-B1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWRestrictive Declaration/Easement 32
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISZONING EXHIBIT II: CERTIFICATION1
05/15/2024121253981Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/15/2024121253981Open ↗
▸BISZONING EXHIBIT V: CERTIFICATION1
05/15/2024121253981Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
05/15/2024121253981Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
05/15/2024121253981Open ↗
▸BISZONING EXHIBIT IV: CERTIFICATION1
05/15/2024121253981Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications101
▸DOB NOWDPL-1: Design Professional Seal & Signature43
09/02/2026M00748027-I1Open ↗
08/31/2026M00867924-I1Open ↗
08/31/2026M00860174-I1Open ↗
Showing 3 of 43 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature28
09/23/2026M00599489-S7Open ↗
09/14/2026M00599489-S9Open ↗
09/14/2026M00599489-S9Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWProgress Inspector Seal & Signature28
09/14/2026M00599489-S9Open ↗
09/14/2026M00599489-S9Open ↗
09/14/2026M00599489-S9Open ↗
Showing 3 of 28 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
01/25/2022141006818Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/25/2022141006818Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
08/13/2026M00599489-I1—
▸Safety & Tenant Protection12
▸DOB NOWStreet Tree Checklist8
08/13/2026M00599489-P6Open ↗
08/13/2026M00599489-A2Open ↗
08/13/2026M00599489-A1Open ↗
Showing 3 of 8 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
07/29/2022141006818Open ↗
▸BISSTREET TREE CHECKLIST1
11/13/2024141006818Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026M00599489-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos27
▸DOB NOWOER: Notice to Proceed19
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 19 on file for this type
▸DOB NOWOER: Notice of Satisfaction6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
01/13/2026141006818Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
07/29/2022141006818Open ↗
▸Energy Compliance5
▸DOB NOWEN2: As Built Energy Analysis.3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸DOB NOWPreliminary Commissioning Report Certification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Inspections & Test Reports4
▸BISBPP: SIDEWALK CONCRETE STRENGTH REPORT1
02/24/2026141006818Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026M00599489-S3Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026M00599489-S3Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026M00599489-S3Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
02/19/2026141006818Open ↗
▸Cost, Insurance & Ownership1
▸BISBPP: ENGINEERS AFFIDAVIT1
02/24/2026141006818Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
11/13/2024141006818Open ↗
07/29/2022141006818Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/25/2022141006818Open ↗
▸Other Documents34
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸DOB NOWProperty Ownership Certification8
08/30/2026M00599489-A2Open ↗
08/30/2026M00599489-A1Open ↗
08/30/2026M00599489-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSite Survey: Initial8
08/13/2026M00599489-A2Open ↗
08/13/2026M00599489-P1Open ↗
Showing 2 of 8 on file for this type
▸BISRECORDS MGMT FEE PAYMENT RECEIPT2
05/16/2024121253981Open ↗
07/29/2022141006818Open ↗
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
01/25/2022141006818Open ↗
▸BISBPP-PARKS: PLANT NEW TREE1
02/24/2026141006818Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
05/15/2024121253981Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
11/13/2024141006818Open ↗
▸BISBPP: SIDEWALK & ROADWAY THICKNESS CORES1
02/24/2026141006818Open ↗
▸DOB NOWFinal Survey1
08/13/2026M00599489-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026M00599489-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026M00599489-S3Open ↗