HPD05/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HANDRAIL AT PUBLIC HALL, 1st STORY
HPD05/27/2026§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD05/27/2026§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD STORAGE AT BALCONY AT 2ND STORY AT FRONT AT FIRE ESCAPE
HPD05/19/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL, 1st STORY
HPD05/19/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL STAIRS, 3rd STORY
HPD05/19/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL STAIRS, 1st STORY
HPD05/19/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT PUBLIC HALL STAIRS, 2nd STORY
HPD10/16/2024§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4FW, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD10/16/2024§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT FIRE DOOR AT WEST AT PUBLIC HALL, 1st STORY
HPD05/17/2023§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCONNECTED METAL HEAT RADIATOR AT PUBLIC HALL, 1st STORY
HPD06/04/2018§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD04/10/2018§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB03/18/1994V-DOB VIOLATION - ACTIVE
DOB03/18/1993V-DOB VIOLATION - ACTIVE
ECB04/29/1992FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECTS IS 1.BRICK MISSINGTHROUGHOUT & ERRODED MORTAR JOINTS AT REAR EAST SECTION OF WALL.2. PARAPET & CHIMNEY CRACKED AT REAR EAST SECTION OF BUILDING.REMEDY:MAKENothing owed — awaiting certificate of correction
ECB10/30/1991FAILURE TO MAINTAIN EXTERIOR BUILDING WALL:DEFECT IS (1)BRICK MISSING AND VOIDS IN MORTOR THROUGHOUT EAST WALL FROM GROUND TO ROOF PARAPET. (2)CHIMNEY BULGDING FROM 5TH FLOOR TO ROOF. REMEDY:PROVIDE PROTECTIONNothing owed — awaiting certificate of correction