← Back
Two family frame
409 DAVIS AVENUE
STATEN ISLAND · West New Brighton-Silver Lake-Grymes Hill · BIN 5003737
💬 Discuss this project
2018Year Built
2Stories
B2Building Class
R3XZoning
2,600 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · Owner of record: YANG YANG 409 LLC · 4,739 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Floor 11p · 1 filing · 2 docs
Sub-Basement1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M JORDAN GENERAL CONTRACTING503/22/2026
WESTPOINT DEVELOPMENT203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALPHA HOME DESIGN LLC102/10/2021
ROGERS CALVANICO GROUP PLLC101/09/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YILIN CONSTRUCTION INCGeneral Contractor303/21/2026
M. JORDAN GENERAL CONTRACTINGGeneral Contractor203/21/2026
Building Lifecycle
All (8)Filed (2)Permit Issued (2)Signed Off (2)Violation (1)Special Inspection (1)
03/01/2021
Signed off — Alteration
REMOVE ECB VIOLATION: 39034290X; REMOVE ILLEGAL PARTITION WALL & DOORS AND RESTORE BACK TO PRIOR LEGAL CONDITION AS PER CO #520330080F. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S00468347-I1
02/16/2021
Permit issued — General Construction
S00468347-I1-GC
02/10/2021
Filed — Alteration
REMOVE ECB VIOLATION: 39034290X; REMOVE ILLEGAL PARTITION WALL & DOORS AND RESTORE BACK TO PRIOR LEGAL CONDITION AS PER CO #520330080F. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S00468347-I1
02/10/2021
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
01/05/2021
Violation issued (ECB, closed)
Construction
05/13/2019
Signed off — Alteration
S00117319-I1
01/09/2019
Filed — Alteration
S00117319-I1
01/09/2019
Permit issued — Curb Cut
S00117319-I1-CC
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offYILIN CONSTRUCTION INC02/16/2021
DOB NOWCurb CutSigned-offM. JORDAN GENERAL CONTRAC01/09/2019
BISPLISSUEDQUALITY PLUMBING, INC06/20/2018
BIS—ISSUEDM. JORDAN GENERAL CONTRACTING06/04/2018
BIS—ISSUEDM. JORDAN GENERAL CONTRACTING05/14/2018
1 project · most recent 09/10/2018
General Wiring
FiledStatusContractorScope
09/10/2018CompleteLASER LITE ELECT'L INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
02/10/2021Energy Code Compliance InspectionsYAN GAOprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Curb Cut1
08/26/2026S00117319-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/25/2026S00468347-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/25/2026S00468347-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026S00468347-I1Open ↗
08/13/2026S00117319-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026S00468347-I1Open ↗