← Back
Two family converted from one family
41-61 54 STREET
QUEENS · BIN 4030980
💬 Discuss this project
1910Year Built
2Stories
B3Building Class
R5BZoning
1,304 sfGross Floor Area
2Units
1 Open Violation ▸
Two family converted from one family · 2,500 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THE OWNER OF203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC310/14/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM EXPEDITING DRAFTING DESIGN603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AM EXPEDITING DRAFTING &General Contractor307/08/2026
WASOFF PLBG & UTILITY COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244205/17/2021
Building Lifecycle
All (45)Filed (3)Permit Issued (3)Signed Off (3)Violation (11)Inspection (4)Objection (18)Special Inspection (3)
02/23/2022
Signed off — Alteration
PROPOSE NEW BATHROOMS ON FIRST FLOOR AND REMOVE SHOWER FROM CELLAR.
Q00520689-I1
02/04/2022
Signed off — Alteration
INTERIOR AND EXTERIOR RENOVATION TO RESOLVED VIOLATION #34916155X,#34904810P, #34904811R, #34881021N.
Q00519206-I1
02/04/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/04/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/05/2022
Signed off — Alteration
INSTALL TEMPORARY CONSTRUCTION FENCE IN THE FRONT YARD.
Q00611606-I1
01/04/2022
Inspection — Pass-Final Fence Non-Directive 14
Pass
View inspection ↗
12/09/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/10/2021
Permit issued — Plumbing
Q00520689-I1-PL
10/29/2021
Permit issued — Construction Fence
Q00611606-I1-FN
10/18/2021
Objection raised — Inspections
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection raised — Structural
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection raised — Scope
10/18/2021
Objection resolved — Addressed
10/18/2021
Objection raised — Structural
10/18/2021
Objection resolved — Addressed
10/14/2021
Filed — Alteration
INSTALL TEMPORARY CONSTRUCTION FENCE IN THE FRONT YARD.
Q00611606-I1
10/07/2021
Permit issued — General Construction
Q00519206-I1-GC
08/19/2021
Objection raised — Scope
08/19/2021
Objection resolved — Addressed
06/15/2021
Objection raised — Zoning
06/15/2021
Objection resolved — Addressed
06/15/2021
Objection raised — Other
06/15/2021
Objection resolved — Addressed
06/15/2021
Objection raised — Other
06/15/2021
Objection resolved — Addressed
05/19/2021
Objection raised — Scope
05/19/2021
Objection resolved — Addressed
05/17/2021
Filed — Alteration
PROPOSE NEW BATHROOMS ON FIRST FLOOR AND REMOVE SHOWER FROM CELLAR.
Q00520689-I1
05/17/2021
Filed — Alteration
INTERIOR AND EXTERIOR RENOVATION TO RESOLVED VIOLATION #34916155X,#34904810P, #34904811R, #34881021N.
Q00519206-I1
05/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
05/17/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
05/10/2021
Special inspection requirement — Final
XIONGCAI GU
02/06/2012
Violation issued (ECB, closed)
Construction
04/14/2011
Violation issued (ECB, closed)
Construction
04/14/2011
Violation issued (ECB, closed)
Quality of Life
02/09/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/11/2010
Violation issued (ECB, closed)
Construction
05/01/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/01/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/04/2003
Violation issued (ECB, closed)
Quality of Life
04/28/2001
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
04/28/2001
Violation issued (ECB, closed)
Quality of Life
04/28/2001
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWASOFF PLBG & UTILITY CO11/10/2021
DOB NOWConstruction FenceSigned-offAM EXPEDITING DRAFTING &10/29/2021
DOB NOWGeneral ConstructionSigned-offAM EXPEDITING DRAFTING &10/07/2021
BISOTISSUEDA1 TOPLINE CONSTRUCTION01/17/2012
BISOTISSUEDA1 TOPLINE CONSTRUCTION01/03/2011
BISPLISSUEDW.R. PLBG AND HTG CORP07/16/2008
BIS—ISSUEDTHREE STAR CONSTRUCTION CO INC04/17/2008
BIS—ISSUEDTHREE STAR CONSTRUCTION CO INC03/26/2008
BISPLISSUEDULTIMATE PLBG AND HTG COR11/08/2004
BIS—ISSUEDAAA GENERAL CONTRACTING08/13/2004
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
02/04/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/04/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/04/2022Pass-Final Fence Non-Directive 14PassView ↗
12/09/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
05/17/2021Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
05/17/2021HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
05/10/2021FinalXIONGCAI GUprogress
▾Documents — 58 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/15/2026Q00520689-I1Request digital key ↗
08/14/2026Q00611606-I1Request digital key ↗
08/14/2026Q00519206-I1Request digital key ↗
▸Applications & Permits15
▸BISPLAN / WORK APPROVAL APPLICATION8
02/27/2012420301621Open ↗
05/27/2011420301621Open ↗
04/02/2011420301621Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION5
01/17/2012420301621Open ↗
01/04/2011420301621Open ↗
07/16/2008410048531Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/29/2008410048531Open ↗
▸BISRescission of Intent to Revoke Approval/Permit1
01/10/2014410048531Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISTAX LOT- FINAL LOT NUMBER ISSUED1
04/29/2010410048531Open ↗
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED1
04/28/2010410048531Open ↗
▸Seals & Professional Certifications15
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
01/03/2011420301621Open ↗
04/28/2010410048531Open ↗
01/09/2008410048531Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00520689-I1Open ↗
08/13/2026Q00611606-I1Open ↗
08/13/2026Q00519206-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
01/03/2011420301621Open ↗
01/09/2008410048531Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
01/03/2011420301621Open ↗
01/09/2008410048531Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026Q00519206-I1Open ↗
08/23/2026Q00519206-I1Open ↗
▸BISPC FULL REPORT1
01/09/2008410048531Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00519206-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING2
09/17/2008410048531Open ↗
08/14/2008410048531Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
11/05/2008410048531Open ↗
▸Safety & Tenant Protection1
▸BISST-1: Street Tree Checklist1
06/06/2008410048531Open ↗
▸Environmental & Asbestos3
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
01/03/2011420301621Open ↗
01/09/2008410048531Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026Q00520689-I1Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00519206-I1Open ↗
08/13/2026Q00520689-I1Open ↗
▸Approvals, Objections & Sign-offs7
▸BISADMINISTRATIVE OBJECTIONS2
01/03/2011420301621Open ↗
01/09/2008410048531Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
04/28/2010410048531Open ↗
04/28/2010410048531Open ↗
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST2
01/19/2012420301621Open ↗
04/29/2010410048531Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE1
04/29/2010410048531Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
01/19/2012420301621Open ↗
01/03/2011420301621Open ↗
04/28/2010410048531Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
01/03/2011420301621Open ↗
▸BISADDITIONAL INFORMATION1
04/28/2010410048531Open ↗