← Back
Two family converted from one family
41 EVERGREEN AVENUE
STATEN ISLAND · Grasmere-Arrochar-South Beach-Dongan Hills · BIN 5048759
💬 Discuss this project
1925Year Built
2.5Stories
B3Building Class
R3XZoning
1,652 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 5,000 sf lot · 0.33 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 9 docs
Floor 1
Site & exterior2p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.109/14/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637109/14/2023
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Violation (1)Special Inspection (12)
12/22/2023
Violation issued (ECB, closed)
Construction
09/18/2023
Permit issued — General Construction
S00932099-I1-GC-CX
09/14/2023
Filed — Alteration
FILE GC & MS WORK TO INSTALL A NEW WOODEN DECK ON EXTERIOR, AND MECHANICAL SYSTEM AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S00932099-I1
09/13/2023
Special inspection requirement — Fenestration air leakage
Robert Truskosky
09/13/2023
Special inspection requirement — Fenestration areas
Robert Truskosky
09/13/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Robert Truskosky
09/13/2023
Special inspection requirement — Air barrier - visual inspection
Robert Truskosky
09/11/2023
Special inspection requirement — Fire-Resistance Rated Construction
Robert Truskosky
09/11/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
09/11/2023
Special inspection requirement — Mechanical Systems
Robert Truskosky
09/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
09/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
09/11/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
09/11/2023
Special inspection requirement — Final
Robert Truskosky
09/11/2023
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION09/18/2023
1 project · most recent 09/14/2023
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/14/2023Permit IssuedHIGH QUALITY CONSTRUCTIONAir Conditioning Systems
Cooling
Gree MULTIE24HP230VIAO 24,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 09/25/2023
General Wiring
FiledStatusContractorScope
09/25/2023Permit IssuedKJK ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
09/13/2023Fenestration air leakageRobert Truskoskyenergy_progress
09/13/2023Fenestration areasRobert Truskoskyenergy_progress
09/13/2023Fenestration and door U-factor and product ratingsRobert Truskoskyenergy_progress
09/13/2023Air barrier - visual inspectionRobert Truskoskyenergy_progress
09/11/2023Fire-Resistance Rated ConstructionRobert Truskoskyprogress
09/11/2023HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
09/11/2023Mechanical SystemsRobert Truskoskyspecial
09/11/2023HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
09/11/2023HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
09/11/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
09/11/2023FinalRobert Truskoskyprogress
09/11/2023Energy Code Compliance InspectionsRobert Truskoskyprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026S00932099-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026S00932099-I1Open ↗
09/01/2026S00932099-I1Open ↗
09/01/2026S00932099-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026S00932099-I1Open ↗
09/01/2026S00932099-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026S00932099-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026S00932099-I1Open ↗