ECB06/01/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ATOI, OBSERVED SUBJECT PROPERTY ABANDONED IN A DETERIORATING CONDITION. LOWER LEVEL WINDOW MISSING AND SIDINGS BULGING AT EXPOSURE 4. PREMISES PERIMETERS U$500 due
HPD08/09/2023§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
DOB04/21/2023V-DOB VIOLATION - ACTIVE
DOB11/22/2022V-DOB VIOLATION - ACTIVE
ECB03/23/2022FAILURE TP MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED EXCESSIVE AMOUNT OF GARBAGE AND DEBRIS AT FRONT AND SIDE OF PROPERTY SUCH AS WOOD, METAL, CLOTH,...ETC., REPAIR AND/OR REPLACE$3K due
DOB02/22/2022V-DOB VIOLATION - ACTIVE
DOB02/16/2022FAILURE TO COMPLY WITH COMMISSIONER'S ORDER# 356884 ISSUED ON 4/30/21 TO OBTAIN PERMIT BY 7/15/21 TO REPAIR THE BUILDING. AS OF 2/16/2022 NO JOB WAS FILED WITH THE DEPARTMENT IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER#357351
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/15/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB07/21/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/09/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/30/2021FAILURE TO MAINTAIN:2 1/2 STORY+CELLAR WOOD FRAME DETACHED RESIDENTIAL BUILDING.THE EAST WALL IS BOWING OUTWARD AT 1ST FLOOR.WALL FRAMING IS EXPOSED AND IS ROTTED.WINDOW IS MISSING.SIDING IS IN STATE OF DISREPR OWNER TO ENGAGE NYS LICENSED PE AND CONTRACTOR TO REPAIR BUILDING UNDR PERMIT.FILE FOR PERMIT BY 06/15/2021.START WORK BY 07/15/2021
ECB04/30/2021FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT T.O.I. AT EXPOSURE#4 THERE IS A SEVERE BULGE IN THE WALL AT 1ST FLOOR LEVEL BELOW A WINDOW OPENING WITHOUT AN ACTUAL WINDOW.THIS BULGE COULD IND$12K due
DOB04/28/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB03/18/2021FAILURE TO MAINTAIN BLDG TO CODECOMPLIANCE NOTED:@EXP4(RIGHT SIDE) THERES VERY SEVERE BULGE IN WALL@1FL LEVEL&DIRECTLY BELOW OR IN LINE OF WINDOW.THIS COULD INDICATE STRUCTURAL DAMAGE&POSSIBLE COLLAPSE.FURTHER$12K due
ECB02/05/2021FAILURE TO MAINTAIN BUILDING WALL(S) AND APPURTENANCES. AT TIME OF INSPECTION OBSERVED AT EXPOSURE #4 WALL AT 1ST FLOOR BULGING SEVERELY APPROXIMATELY 8" INTO SIDE YARD., MAINTAIN EXTERIOR BUILDING WALL$10K due
ECB08/10/2021FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTED:AT EXP.#4,THE FACADE WALL IS BULGING OUTWARD APPROX. 3 FEET AT 1ST FLOOR LEVEL. REMEDY: REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB06/17/2021FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT EXP 4 FACADA WALL BUILDING OUTWARD APPROX 3FT AT 1ST FL LEVEL.REMEDY:REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB09/16/2004FAILURE TO PROVIDE APPROVED PLANS AT PREMISE AT TIME OF INSPECTION. REMEDY: PROVIDE APPROVED PLANS/STOP ALL WORK FORTHWITH, CONTACT D.O.B.S.I. OFFICE PRIOR TO RESUMING WORK.Nothing owed — awaiting certificate of correction
ECB09/16/2004AT TIME OF INSPECTION QUESTIONAIRE CONSTRUCTION OBSERVED 1)HEADER AT 1ST FLOOR CEILING (LEFT SIDE WHEN FACING BUILD) 1ST NOT PROPERLY SUP- PORTED (LOAD BEARING). 2)TICO CONNECTORS ARE NOT PROPERLY INSTALLEDNothing owed — awaiting certificate of correction
ECB06/10/2004FAILURE TO MAINTAIN EXTERIOR BUILDING WALL/DEFECTS ARE/AT NORTH SIDEWALL -1ST FLOOR LEVEL -APPROX. 150 SQ. FT. OF WOOD FRAME SIDEWALL HAS BULGED OUT OF PLUMB APPROX. 8" FROM VERTICAL.REMEDY:MAKE ALL NECESSARY RNothing owed — awaiting certificate of correction