← Back
One family attached or semi-detached
41 LOTT LANE
STATEN ISLAND · New Springville-Willowbrook-Bulls Head-Travis · BIN 5126033
💬 Discuss this project
1996Year Built
2Stories
A5Building Class
R3-2Zoning
—Gross Floor Area
1Units
One family attached or semi-detached · 0.76 FAR built · Flood zone X
Locations of Work
Electrical
Roof1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M D L CONSTRUCTION203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR105/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281105/21/2026
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Inspection (2)Special Inspection (5)
08/25/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/11/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/08/2026
Permit issued — Solar
S01405314-I1-SL
05/21/2026
Filed — Alteration
Installation of solar panels, rooftop, grid tied, railed, 16 modules, 6.56 KW
S01405314-I1
05/21/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mina Makar
05/21/2026
Special inspection requirement — Air barrier - visual inspection
Mina Makar
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mina Makar
05/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Mina Makar
05/20/2026
Special inspection requirement — Final
Mina Makar
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMOMENTUM SOLAR06/08/2026
BIS—ISSUEDDEPAULIS HOLDING CORPORATION11/08/1995
BISPLISSUEDLOUIS L. BUTTERMARK & SONS INC04/21/1995
BIS—ISSUEDPRESTIGE HOLDING CORPORATION03/29/1995
1 project · most recent 05/21/2026
FiledStatusContractorScope
05/21/2026CompleteISLAND ELECTRIC CORP—
1 project · most recent 05/21/2026
FiledStatusContractorScope
05/21/2026Permit IssuedMOMENTUM SOLAR16 panels, 6.56 kw, 2,400 roof_area_sqft
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/25/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/11/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/21/2026Structural Stability – Alterations of existing buildingsMina Makarspecial
05/21/2026Air barrier - visual inspectionMina Makarenergy_progress
05/20/2026Fire-Resistant Penetrations and JointsMina Makarspecial
05/20/2026Energy Code Compliance InspectionsMina Makarprogress
05/20/2026FinalMina Makarprogress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026S01405314-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026S01405314-I1Open ↗
08/25/2026S01405314-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026S01405314-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026S01405314-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026S01405314-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/16/2026S01405314-I1Open ↗