← Back
Two family brick
41 WILSON VIEW PLACE
STATEN ISLAND · BIN 5021450
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R1-2Zoning
2,928 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family brick · 8,925 sf lot · 0.33 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
109 SPICY GOURMET DELI607/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PE AND CONSULTANTS NY LLC206/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ABC PERMIT EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
U.S. LEGACY CONTRACTING CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GRACE ENGINEERING PLLC.2176206/10/2022
Building Lifecycle
All (15)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (9)
07/27/2022
Signed off — Alteration
NEW CONCRETE RETAINING WALL TO REPLACE EXISTING FAILING CMU RETAINING WALL, AS PER DETAIL SHOWN ON PLANS. NO CHANGES TO USES, EGRESS OR OCCUPANCY.
S00470729-I1
06/10/2022
Filed — Alteration
NEW CONCRETE RETAINING WALL TO REPLACE EXISTING FAILING CMU RETAINING WALL, AS PER DETAIL SHOWN ON PLANS. NO CHANGES TO USES, EGRESS OR OCCUPANCY.
S00470729-P1
06/09/2022
Special inspection requirement — Concrete - Cast-In-Place
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Post-installed Anchors
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Structural Steel - Details
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Structural Steel - Welding
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Subgrade Inspections
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Underpinning
TARIQ SIDDIQUI
06/09/2022
Special inspection requirement — Energy Code Compliance Inspections
SRINIVAS THIMMAPPA
06/09/2022
Special inspection requirement — Final
SRINIVAS THIMMAPPA
10/15/2021
Permit issued — Structural
S00470729-I1-GC-CX
06/11/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/22/2021
Filed — Alteration
NEW CONCRETE RETAINING WALL TO REPLACE EXISTING FAILING CMU RETAINING WALL, AS PER DETAIL SHOWN ON PLANS. NO CHANGES TO USES, EGRESS OR OCCUPANCY.
S00470729-I1
10/17/1988
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offU.S. LEGACY CONTRACTING C10/15/2021
BISPLISSUEDKATAN P & H INC10/18/2018
BISOTISSUEDSHAM CONSTRUCTION GROUP09/26/2018
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/09/2022Concrete - Cast-In-PlaceTARIQ SIDDIQUIspecial
06/09/2022Post-installed AnchorsTARIQ SIDDIQUIspecial
06/09/2022Structural Stability – Alterations of existing buildingsTARIQ SIDDIQUIspecial
06/09/2022Structural Steel - DetailsTARIQ SIDDIQUIspecial
06/09/2022Structural Steel - WeldingTARIQ SIDDIQUIspecial
06/09/2022Subgrade InspectionsTARIQ SIDDIQUIspecial
06/09/2022UnderpinningTARIQ SIDDIQUIspecial
06/09/2022Energy Code Compliance InspectionsSRINIVAS THIMMAPPAprogress
06/09/2022FinalSRINIVAS THIMMAPPAprogress
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Structural2
08/24/2026S00470729-P1Request digital key ↗
08/24/2026S00470729-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction2
08/24/2026S00470729-P1Request digital key ↗
08/24/2026S00470729-I1Request digital key ↗
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
10/18/2018520353876Open ↗
09/27/2018520353876Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
11/16/2018520353876Open ↗
08/07/2018520353876Open ↗
▸Seals & Professional Certifications17
▸DOB NOWSpecial Inspector Seal & Signature7
09/10/2026S00470729-P1Open ↗
09/10/2026S00470729-P1Open ↗
09/10/2026S00470729-P1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
06/03/2019520353876Open ↗
06/03/2019520353876Open ↗
06/03/2019520353876Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026S00470729-P1Open ↗
08/24/2026S00470729-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/10/2026S00470729-P1Open ↗
09/10/2026S00470729-P1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/16/2018520353876Open ↗
08/07/2018520353876Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
08/07/2018520353876Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/19/2018520353876Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/03/2019520353876Open ↗
08/07/2018520353876Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/03/2019520353876Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/03/2019520353876Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
09/20/2018520353876Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
06/03/2019520353876Open ↗
08/07/2018520353876Open ↗
▸Filing & Intake Forms3
▸BISBOROUGH INTAKE FORM2
06/03/2019520353876Open ↗
11/16/2018520353876Open ↗
▸BISEFILING COVER SHEET1
08/07/2018520353876Open ↗