ECB07/16/2018FAILURE TO SUBMIT ACCEPTABLE 8TH FOUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #813007. RMDY: SUBMIT REQUIRED TECHNICAL REPORT.$6K due
ECB01/07/2025AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED UNDERSIDE OF SIDEWALK SHED A NOT ILLUMINATED AS PER 3307.6.4.8. THIS CREATES A HAZARDOUS CONDITION FOR PUBLIC WALKING UNDERNEATH WHILE DARK AND NOT BEINNothing owed — awaiting certificate of correction
ECB11/14/2023AT TIME OF INSPECTION OBSERVED POWER HOUSE BUILDING FACADE IN STATE OF DISREPAIR. CRACKS AT MULTIPLE LOCATIONS AT ALL EXPOSURE. SMOKE STACK PARTIALLY COLLAPSE ON ROOF. FRONT CONCRETE/METAL AWNING SAGGING AND INNothing owed — awaiting certificate of correction
ECB12/02/2022FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE7A,8A,9A REPORT OF CRITICALEXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL913011.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB12/02/2022FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE7A,8A,9A REPORT OF CRITICALEXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL913010.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB12/02/2022FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE7A,8A,9A REPORT OF CRITICALEXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL913009.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB12/02/2022FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE7A,8A,9A REPORT OF CRITICALEXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL913008.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB12/02/2022FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE7A,8A,9A REPORT OF CRITICALEXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL913007.SUBMIT ACCEPTABLE REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB11/15/2022ELEVATOR CURRENTLY OUT OF SERVICENothing owed — awaiting certificate of correction
ECB09/30/2022ELECTRICAL WORK WITHOUT A PERMIT OUTSIDE ON THE ROOF LEDGE INSTALLATION OF 7 OUTDOOR ILLUMINATED FIXTURES.REM:OBTAIN PERMIT.Nothing owed — awaiting certificate of correction
ECB03/07/2022NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM ANothing owed — awaiting certificate of correction
ECB07/16/2018FAILURE TO SUBMIT ACCEPTABLE 8TH FOUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #813011. RMDY: SUBMIT REQUIRED TECHNICAL REPORT.Nothing owed — awaiting certificate of correction
ECB07/12/2018FAILURE TO MAINTAIN BLDG WALLS AND APPURTENANCES NOTED AT TIME OF IN SPECTION DEFECTIVE COPINGS WERE OBSERVED AT EXPOSURE 1(EAST ELEVATION)AT SOUTH SECTIONS. RMDY: MAINTAIN BUILDING EXTERIORS.REPAIR DEFECTS.Nothing owed — awaiting certificate of correction
ECB07/12/2018FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. NOTED AT TIME OFINSPECTION (I) AT EXP1 DEFECTIVE EAST ELEVATIONS)SPALLED MASONRY ABOVEMAIN ENTRANCES GATES BETWEEN FLRS AND 2; (II)BROKEN GLASS PANES OBSERVNothing owed — awaiting certificate of correction
ECB07/12/2018FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. NOTED AT TIME OFINSPECTION AT EXP4 (NORTH ELEVATIONS) DETERIORATED METAL CORNICE AT UNDERSIDE OF EAST END. RMDY: MAINTAIN BUILDING EXTERIORS; REPAIR DEFECTSNothing owed — awaiting certificate of correction
ECB07/12/2018FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. NOTED AT TIME OFINSPECTION (I) AT EXP1 DEFECTIVE EAVES AT VARIOUS LOCATION; (II) AT PITCHED ROOF-DETERIORATED AND DISLODGED SIDINGS OBSERVED. RMDY:MAINTAINothing owed — awaiting certificate of correction
ECB05/18/2018FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENACES REQUIRED BY 28-302.4 FOR CONTROL #813009Nothing owed — awaiting certificate of correction
ECB05/16/201397#05 FAILURE TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO ALLOW MANDATORY ANNUAL INSPECTION BY THE DEPT OR APPROVED AGENCY PER 28-304.6.1 AND APPENDIX K OF THE BUILDING CODE. MULTIPLE ATTEMPTS TO GAIN ACCENothing owed — awaiting certificate of correction
Pier, dock, bulkhead · Owner of record: NYC DEPARTMENT OF SMALL BUSINESS SERVICES · 724,000 sf lot · 0.94 FAR built · Flood zone X500