← Back
BuildNYC
Two family brick
411 BRADFORD STREET
BROOKLYN · BIN 3084380
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R6Zoning
1,896 sfGross Floor Area
2Units
Two family brick · 2,000 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Plumbing and duct insulation work4p · 2 filings · 20 docs
Floor 1Plumbing and duct insulation work4p · 2 filings · 20 docs
CellarPlumbing and duct insulation work4p · 2 filings · 20 docs
Site & exterior3p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Elite Properties NYC907/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/04/2021$945K—ELITE PROPERTIES NYC INVESTORS LLC → Private party$498/sf building
04/29/2021$512K—Private party → ELITE PROPERTIES NYC INVESTORS LLC$270/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CX Consulting308/26/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
G Design Drafting603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Xinli ConstructionGeneral Contractor107/08/2026
Prime Piping & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
XC Engineering6692408/26/2021
Building Lifecycle
10/06/2021
Signed off — Alteration
B00527804-I1
10/06/2021
Signed off — Alteration
INTERIOR RENOVATION OF (2) FAMILY HOUSE WITH MECHANICAL WORK AS PER PLAN. PLUMBING WORK WILL BE FILED SEPARATELY.NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00527802-I1
09/02/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/30/2021
Special inspection requirement — Mechanical Systems
XIU CHEN
08/30/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIU CHEN
37 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPrime Piping & Heating06/18/2021
DOB NOWGeneral ConstructionSigned-offXinli Construction06/11/2021
1 project · most recent 10/22/2021
General Wiring
FiledStatusContractorScope
10/22/2021CompleteApproved ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
09/02/2021Pass-Final General Construction Non-Directive 14PassView ↗
08/25/2021Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
08/30/2021Mechanical SystemsXIU CHENspecial
08/30/2021Fire-Resistant Penetrations and JointsXIU CHENspecial
08/30/2021FinalXIU CHENprogress
08/30/2021Energy Code Compliance InspectionsXIU CHENprogress
08/30/2021HVAC-R and service water heating equipmentXIU CHENenergy_progress
08/30/2021HVAC-R and service water heating system controlsXIU CHENenergy_progress
08/30/2021Interior lighting powerXIU CHENenergy_progress
08/30/2021Fenestration air leakageXIU CHENenergy_progress
08/30/2021Air barrier - visual inspectionXIU CHENenergy_progress
08/30/2021Fenestration areasXIU CHENenergy_progress
08/30/2021Insulation placement and R valuesXIU CHENenergy_progress
08/30/2021HVAC-R and service water piping design and insulationXIU CHENenergy_progress
08/30/2021Fenestration and door U-factor and product ratingsXIU CHENenergy_progress
08/30/2021Duct leakage testing, insulation and designXIU CHENenergy_progress
08/25/2021Fire-Resistant Penetrations and JointsXIU CHENspecial
08/25/2021Mechanical SystemsXIU CHENspecial
08/25/2021Energy Code Compliance InspectionsXIU CHENprogress
08/25/2021FinalXIU CHENprogress
08/25/2021Duct leakage testing, insulation and designXIU CHENenergy_progress
08/25/2021Air barrier - visual inspectionXIU CHENenergy_progress
08/25/2021Fenestration and door U-factor and product ratingsXIU CHENenergy_progress
08/25/2021Insulation placement and R valuesXIU CHENenergy_progress
08/25/2021HVAC-R and service water heating equipmentXIU CHENenergy_progress
08/25/2021Fenestration air leakageXIU CHENenergy_progress
08/25/2021Fenestration areasXIU CHENenergy_progress
Latest 25 of 28.
36 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account