ECB07/21/2026CLASS 1 ITEMS: ACCESS TO ELEVATOR MACHINE ROOM WAS NOT PROVIDED AT TIME OF INSPECTION, PREVENTING INSPECTION AND ACCESS TO ELEVATOR EQUIPMENT, IN VIOLATION OF ASME A17.1-2013 2.7.3 AND 8.6.1.2.1, AND NYC ADMINI$625 due
HPD07/01/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT VESTIBULE DOOR (LEFT HAND SIDED DOOR} AT PUBLIC HALL, 1st STORY
HPD07/01/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT, 8th STORY
HPD04/27/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 4D, 4th STORY, 4th APARTMENT FROM WEST AT NORTH , SECTION ''A-H'', AT EAST
ECB01/29/2026CLASS 2: CAR STATION DAMAGED LOOSE AND OPENED, REPAIR CAR STATION LOOSE AND OPENED. BROKEN SAFETY MIRROR IN CAB, REPLACE BROKEN SAFETY MIRROR. DIRTY CAR TOP, CLEAN TOP OF CAR. MISSING NYC ID TAG ON TOP OF CAR,$3K due
ECB12/23/2025CONTRARY TO C-OF-O 20085964 WHICH INDICATES 3RD FLR AS 12 CLASS 'A' APTS - AT TIME OF INSPECTION: APT 3L OBSERVED CREATED & OCCUPIED AS 3 SRO'S (1 UNOCCUPIED). SRO'S FOUND WITH REFRIGERATOR, BED, FOOD, COOKING$1K due
ECB12/23/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - 1. EXCESSIVE VOLUME OF GARBAGE OBSERVED ACCUMULATED & STORED AT LOBBY FLR OF PREMISES: 2. AT 3RD FLR COMMON HALL - ELECTRICA$3K due
ECB12/23/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). NOTED: AT TIME OF INSPECTION - KEY LOCKING DEVICES WERE OBSERVED INSTALLED AT ALL BDRM E$1K due
ECB12/23/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION - OBSERVED 3RD FLR INTERIOR FIRE RATED CORRIDOR DOORS NOT SELF CLOSING: CREATING A FIRE HAZARD CONDITION., REPAIR AND/OR REPLA$1K due
ECB12/23/2025W/O A PERMIT. NOTED: AT 3RD FLR APT 3L - PARTITION WALL & SWING DOOR INSTALLED TO CLOSE LIVING RM OPENING & CREATE AN ADDL'T BDRM., OBTAIN ALL PERMITS; RESTORE TO PRIOR LEGAL CONDITION OR LEGALIZE...$1K due
ECB12/09/2025FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION: AS NOTED AT TIME OF INSPECTION OF AN OCCUPIED PARKING STRUCTURE CONSISTING 1 LEVEL BELOW THE BUILDING. OBSERVED SPALLING AND WATER LEAK ALSO SOME MISSING$12K due
ECB10/24/2024FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0003798 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS$2K due