← Back
Two family frame
4115 AVENUE T
BROOKLYN · BIN 3241258
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R4Zoning
1,292 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · 2,000 sf lot · 0.65 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 23p · 1 filing · 3 docs
Floor 13p · 1 filing · 3 docs
Cellar3p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/19/2023$650K—Private party → Private party$503/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN ENGINEERING CONSULTANT PLLC705/27/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING SOLUTIONS703/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EAM TOP CONSTRUCTION INCGeneral Contractor603/21/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415605/27/2025
Building Lifecycle
All (41)Filed (7)Permit Issued (4)Signed Off (1)Violation (1)Inspection (4)Objection (14)Special Inspection (10)
06/05/2025
Signed off — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-I1
05/27/2025
Filed — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-P4
05/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
05/27/2025
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/15/2025
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
05/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
09/26/2024
Filed — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-P3
09/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
09/18/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
08/30/2024
Filed — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-P2
08/27/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
08/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
08/15/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/01/2024
Filed — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-P1
07/29/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
07/24/2024
Special inspection requirement — Energy Code Compliance Inspections
DOYUN KIM
07/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/03/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/21/2024
Permit issued — Plumbing
B00955410-I1-PL
04/17/2024
Objection raised — Scope
04/10/2024
Objection resolved — Addressed
04/10/2024
Objection resolved — Addressed
03/14/2024
Objection raised — Scope
03/14/2024
Objection raised — Scope
03/11/2024
Objection resolved — Addressed
03/11/2024
Objection resolved — Addressed
02/29/2024
Objection resolved — Addressed
02/29/2024
Objection resolved — Addressed
02/08/2024
Objection raised — Scope
02/08/2024
Objection raised — Scope
02/08/2024
Objection raised — Scope
02/08/2024
Objection raised — Scope
02/08/2024
Objection raised — Scope
01/29/2024
Filed — Alteration
HEREWITH FILED TO PROPOSE INTERIORRENOVATION , RELAMINATE EXISTING WALLS,WNEW FINISHES AS PER PLANS. TO EXISTING 2FAMILY DWELLING NO CHANGE IN USE EGRESSOR OCCUPANCY. NEW REAR ONE STORYENLARGEMENT
B00972221-I1
12/19/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/07/2023
Permit issued — Plumbing
B00955410-I1-PL
12/05/2023
Filed — Alteration
HEREWITH TO PROPOSE PLUMBING SYSTEM AS PER PLANS. IN CONJUNCTION WITH DOB #B00953580.
B00955410-I1
11/30/2023
Permit issued — General Construction
B00953580-I1-GC
11/21/2023
Permit issued — General Construction
B00953580-I1-GC
11/04/2023
Filed — Alteration
B00953580-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING06/21/2024
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT12/07/2023
DOB NOWGeneral ConstructionPermit IssuedEAM TOP CONSTRUCTION INC11/30/2023
DOB NOWGeneral ConstructionPermit IssuedEAM TOP CONSTRUCTION INC11/21/2023
1 project · most recent 10/24/2023
General Wiring
FiledStatusContractorScope
10/24/2023CompleteRONEY ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/15/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/03/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/19/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/27/2025Fire-Resistant Penetrations and JointsDOYUN KIMspecial
05/27/2025Energy Code Compliance InspectionsDOYUN KIMprogress
05/15/2025Energy Code Compliance InspectionsDOYUN KIMprogress
05/15/2025Fire-Resistant Penetrations and JointsDOYUN KIMspecial
09/18/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
09/18/2024Energy Code Compliance InspectionsDOYUN KIMprogress
08/27/2024Energy Code Compliance InspectionsDOYUN KIMprogress
08/27/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
07/24/2024Fire-Resistant Penetrations and JointsDOYUN KIMspecial
07/24/2024Energy Code Compliance InspectionsDOYUN KIMprogress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026B00953580-I1Request digital key ↗
08/26/2026B00955410-P2Request digital key ↗
08/26/2026B00955410-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00972221-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026B00953580-I1Open ↗
08/26/2026B00955410-I1Open ↗
08/26/2026B00955410-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026B00955410-P3Open ↗
08/27/2026B00955410-P2Open ↗
08/26/2026B00955410-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/27/2026B00955410-P3Open ↗
08/27/2026B00955410-P2Open ↗
08/26/2026B00955410-P1Open ↗
Showing 3 of 5 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026B00972221-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/26/2026B00953580-I1Open ↗
08/26/2026B00955410-P1Open ↗
08/26/2026B00955410-I1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026B00972221-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00972221-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B00972221-I1Open ↗