← Back
One story retail building
4125 LACONIA AVENUE
BRONX · Wakefield-Woodlawn · BIN 2065208
💬 Discuss this project
1958Year Built
1Stories
K1Building Class
R5DZoning
14,800 sfGross Floor Area
8Units
20 Open Violations 18 unresolved · 2 paperwork only ▸
One story retail building · Owner of record: LACONIA PROPERTIES · 32,250 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction13p · 3 filings · 20 docs
Floor 1Under Construction9p · 2 filings · 20 docs
CellarUnder Construction17p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DITMARS REAL ESTATE CONSULTANTS1507/16/2026
GITTO LACONIA 41411407/08/2026
LACONIA PROPERTIES2103/22/2026
PROPERTIES LACONIA103/22/2026
LACONIA REALTY803/21/2026
4141 LACONIA AVENUE103/21/2026
ASSOCIATED SUPERMARKET103/21/2026
DITMARS CONSULTANTS303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BRIAN MCDONOUGH, PE108/01/2025
AR ARCHITECT P.C511/14/2024
AUTOMATED DESIGN ENGINEERING, PLLC304/13/2024
HANSEN ENGINEERING, PC112/21/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JANCO BUILDING CONSULTANTS203/21/2026
ADAC CONSTRUCTION1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AQUEDUCT MECHANICAL CORPPlumbing307/16/2026
DERRICK RAMDEENElectrical103/21/2026
TEMPEST ELEC'L CONTRG, INElectrical103/22/2026
UNITED INDUSTRIES & CONSTGeneral Contractor107/08/2026
YAFE MEOD CORPGeneral Contractor107/08/2026
SIGNORE & SONS PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MCDONOUGH ENGINEERING PRA9377108/01/2025
AR ARCHITECT P.C.1171511/14/2024
HANSEN ENGINEERING PC8174212/21/2022
Building Lifecycle
All (80)Filed (10)Permit Issued (6)Violation (27)Inspection (7)Objection (10)Special Inspection (20)
07/29/2026
Inspection — Fail-Final Builders Pavement Plan (BPP)
Fail
View inspection ↗
07/15/2026
Permit issued — Plumbing
X07998676-S2-PL
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/01/2025
Filed — Alteration
Installation of Kitchen Exhaust Fan, Kitchen Exhaust Hood and associated ductwork as required.
X01260373-I1
07/23/2025
Special inspection requirement — Mechanical Systems
Brian McDonough
07/23/2025
Special inspection requirement — Final
Brian McDonough
11/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
11/21/2024
Special inspection requirement — Final
ANGEL ROJAS
11/21/2024
Special inspection requirement — Mechanical Systems
ANGEL ROJAS
11/14/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING SUPERMARKET WITH NEW COMMERCIAL KITCHEN ON FIRST FLOOR. INSTALLATION OF NEW GAS SHUT-OFF VALVE /PLUMBING EQUIPMENT. INSTALL COMMERCIAL HOOD AND DUCTWORK FOR EXISTING DELI. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00893445-P3
11/04/2024
Special inspection requirement — Final
ANGEL ROJAS
11/04/2024
Special inspection requirement — Final
ANGEL ROJAS
11/04/2024
Special inspection requirement — Mechanical Systems
ANGEL ROJAS
11/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
11/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
11/04/2024
Special inspection requirement — Mechanical Systems
ANGEL ROJAS
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/19/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/13/2024
Filed — Alteration
Filed to amend -S1 to Legalize existing gas fired appliances such as RTU's, water heaters, furnaces, unit heaters, and various commercial kitchen equipment. There is no change in use, occupancy, egress.
X07998676-S2
03/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/13/2024
Permit issued — Plumbing
X07998676-S1-PL
01/10/2024
Filed — Alteration
Filed to amend -S1 to Legalize existing gas fired appliances such as RTU's, water heaters, furnaces, unit heaters, and various commercial kitchen equipment. There is no change in use, occupancy, egress.
X07998676-S1
01/02/2024
Objection resolved — Addressed
12/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
12/26/2023
Objection resolved — Addressed
12/21/2023
Objection raised — Scope
12/19/2023
Objection raised — Admin
12/18/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING SUPERMARKET WITH NEW COMMERCIAL KITCHEN ON FIRST FLOOR. INSTALLATION OF NEW GAS SHUT-OFF VALVE /PLUMBING EQUIPMENT. INSTALL COMMERCIAL HOOD AND DUCTWORK FOR EXISTING DELI. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00893445-P2
12/18/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING SUPERMARKET WITH NEW COMMERCIAL KITCHEN ON FIRST FLOOR. INSTALLATION OF NEW GAS SHUT-OFF VALVE /PLUMBING EQUIPMENT. INSTALL COMMERCIAL HOOD AND DUCTWORK FOR EXISTING DELI. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00893445-P1
12/11/2023
Permit issued — Plumbing
X00893445-S1-PL
12/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
12/08/2023
Special inspection requirement — Final
ANGEL ROJAS
12/08/2023
Special inspection requirement — Mechanical Systems
ANGEL ROJAS
12/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANGEL ROJAS
11/29/2023
Permit issued — General Construction
X00893445-I1-GC-CX
07/18/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Other
07/10/2023
Objection resolved — Addressed
07/07/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/07/2023
Objection resolved — Addressed
07/05/2023
Objection raised — Other
07/05/2023
Objection raised — Scope
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING SUPERMARKET WITH NEW COMMERCIAL KITCHEN ON FIRST FLOOR. INSTALLATION OF NEW GAS SHUT-OFF VALVE /PLUMBING EQUIPMENT. INSTALL COMMERCIAL HOOD AND DUCTWORK FOR EXISTING DELI. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00893445-I1
06/28/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING SUPERMARKET WITH NEW COMMERCIAL KITCHEN ON FIRST FLOOR. INSTALLATION OF NEW GAS SHUT-OFF VALVE /PLUMBING EQUIPMENT. INSTALL COMMERCIAL HOOD AND DUCTWORK FOR EXISTING DELI. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
X00893445-S1
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/15/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/05/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/14/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/12/2023
Permit issued — Structural
X08054305-I1-ST
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAQUEDUCT MECHANICAL CORP07/15/2026
DOB NOWPlumbingPermit IssuedAQUEDUCT MECHANICAL CORP02/13/2024
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP12/11/2023
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP11/29/2023
DOB NOWStructuralPermit IssuedUNITED INDUSTRIES & CONST01/12/2023
DOB NOWPlumbingPermit IssuedAQUEDUCT MECHANICAL CORP10/13/2022
BISOTISSUEDARCON CONSTRUCTION GROUP07/10/2018
BISPLISSUEDDPH PLUMBING & HTG CORP08/17/2012
BISMHISSUEDLITHOS CONSTR SOLUTI INC10/12/2011
BISPLISSUEDMETROCITY GROUP,INC10/12/2011
BISFPISSUEDCITYWIDE FIRE SYS PLBG EN06/22/2011
BISMHISSUEDKRYON MECHANICAL LLC10/20/2009
BISOTISSUEDUNITECH DESIGN INC04/30/2009
BISPLISSUEDDOVAL PLBG & HTG CORP04/15/2008
BISFPISSUEDMASTER FIRE SYSTEMS, INC05/30/2007
BIS—ISSUEDNORTH SHORE NEON SIGN CO04/19/2007
BIS—ISSUEDNORTH SHORE NEON SIGN CO04/19/2007
BIS—ISSUEDNORTH SHORE NEON SIGN CO04/19/2007
BISOTISSUEDCHIAN CONTRACTORS, INC.12/26/2006
BISMHISSUEDYEEAN MECHANICAL CONTRACTING12/12/2006
BISEQISSUEDEVEREST SCAFFOLDING INC09/28/2006
BISOTISSUEDCHIAN CONTRACTORS, INC.09/22/2006
BISEQISSUEDCHIAN CONTRACTORS, INC.09/22/2006
BISEQISSUEDREMY BUILDERS CORP.08/25/2006
BISPLISSUEDCATMAN PLUMBING INC07/26/2006
BISOTISSUEDYEEAN MECHANICAL CONTRACTING07/14/2006
BISOTISSUEDEASTEERN MILLENIUM CONSTRUCTION07/06/1999
BISPLISSUEDWAGNER-WEINTRAUB PLBG. & HTG. EN05/12/1997
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS03/28/1997
BISEQISSUEDHSU & ASSOCIATES03/07/1997
BISOTISSUEDHSU & ASSOCIATES03/07/1997
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS02/13/1992
2 projects · most recent 08/01/2025
Ventilation Systems Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/01/2025——Ventilation Systems
Ventilation
Captiveaire NCA16FA 5,000 CFM · Kitchen Exhaust ×1
11/14/2024Permit IssuedYAFE MEOD CORPAir Conditioning Systems, Ventilation Systems
Cooling
Carrier CARRIER MODEL: 48TME 006---501-- SERIAL 1906G10291 115,000 BTU · Rooftop Unit ×3
MODEL# 48TME006---501-- SERIAL# 1906G10290 115,000 BTU · Rooftop Unit ×3
MODEL# 48TME006---501-- SERIAL#1806G50180 115,000 BTU · Rooftop Unit ×3
Krack KRACK Remote Air Cooled Condenser MODEL : LAVF-24310KA CPC1 NCA412T SSS 50,640 BTU · Condensing Unit ×3
Midea INDOOR#MEHU-12AVH2 OUTDOOR#MCHU-12AVH2 11,500 BTU · Split System ×3
Trenton CONDENSING UNIT MODEL TEHA04E6-HT4B-B SERIAL: 122102557 5,000 BTU · Condensing Unit ×3
Ventilation
Captiveaire DTP0026 4,295 CFM · Exhaust Fan ×3
__Junk__ 0000000 4,500 CFM · Makeup Air ×3
2 projects · most recent 11/14/2024
Gas Water/Sanitary
FiledStatusContractorScope
11/14/2024Permit IssuedSIGNORE & SONS PLBG CORPGas, Water/Sanitary
04/13/2024Permit IssuedPEGASUS P&H CORPGas
6 projects · most recent 12/06/2023
General Wiring
FiledStatusContractorScope
12/06/2023Permit IssuedSNB ELECTRICAL CONTNG CORGeneral Wiring
07/16/2021CompleteALL WAYS ELECTRIC CORP.WGeneral Wiring
12/06/2019Permit IssuedAPPROVED ELECTRIC CORP.General Wiring
08/08/2019CompleteALL CITY ELECTRICAL INC—
05/22/2018Permit IssuedAPPROVED ELECTRIC CORP.General Wiring
03/06/2018CompleteTEMPEST ELEC'L CONTRG, IN8 meters, 8 new_meters
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
07/29/2026Fail-Final Builders Pavement Plan (BPP)FailView ↗
09/19/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/07/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/15/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/05/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/14/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
07/23/2025Mechanical SystemsBrian McDonoughspecial
07/23/2025FinalBrian McDonoughprogress
11/21/2024Fire-Resistant Penetrations and JointsANGEL ROJASspecial
11/21/2024FinalANGEL ROJASprogress
11/21/2024Mechanical SystemsANGEL ROJASspecial
11/04/2024FinalANGEL ROJASprogress
11/04/2024FinalANGEL ROJASprogress
11/04/2024Mechanical SystemsANGEL ROJASspecial
11/04/2024Fire-Resistant Penetrations and JointsANGEL ROJASspecial
11/04/2024Fire-Resistant Penetrations and JointsANGEL ROJASspecial
11/04/2024Mechanical SystemsANGEL ROJASspecial
12/28/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
12/08/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
12/08/2023FinalANGEL ROJASprogress
12/08/2023Mechanical SystemsANGEL ROJASspecial
12/08/2023Fire-Resistant Penetrations and JointsANGEL ROJASspecial
12/20/2022Structural Steel - DetailsRyan Hansenspecial
12/13/2022Structural Stability – Alterations of existing buildingsRyan Hansenspecial
12/13/2022Construction Operations Influencing Adjacent StructuresRyan Hansenspecial
12/13/2022FinalRyan Hansenprogress
▾Documents — 132 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/23/2026X07998676-S1Request digital key ↗
08/23/2026X07998676-S2Request digital key ↗
08/23/2026X07998676-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits18
▸BISWORK PERMIT APPLICATION10
07/12/2018220646665Open ↗
08/20/2012220107845Open ↗
10/12/2011220111590Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION8
09/14/2018220107845Open ↗
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications47
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
06/23/2011220107845Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/23/2026X08054305-I1Open ↗
08/18/2026X01260373-I1Open ↗
08/13/2026X00893445-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/26/2026X08054305-I1Open ↗
09/26/2026X08054305-I1Open ↗
08/25/2026X00893445-P1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
04/08/2011220111590Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/26/2026X08054305-I1Open ↗
08/25/2026X00893445-P1Open ↗
08/24/2026X00893445-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
04/08/2011220111590Open ↗
10/20/2009220032916Open ↗
02/07/2008210033391Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
▸BISPC FULL REPORT1
12/17/2007210027736Open ↗
▸Trade Schedules & Equipment9
▸BISSELF-CERT PLUMBING NOTICE4
12/12/2011220111590Open ↗
12/12/2011220111590Open ↗
05/03/2008210033391Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING3
04/08/2011220111590Open ↗
03/14/2011220107845Open ↗
02/07/2008210033391Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
12/02/2009220032916Open ↗
▸BISEQUIPMENT USE PERMITS1
12/02/2009220032916Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
05/09/2018220646665Open ↗
▸Environmental & Asbestos19
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/23/2026X08054305-I1Open ↗
08/13/2026X00893445-P3Open ↗
08/13/2026X00893445-S1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
04/13/2009220001682Open ↗
02/07/2008210033391Open ↗
12/17/2007210027736Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
04/08/2011220111590Open ↗
03/14/2011220107845Open ↗
10/20/2009220032916Open ↗
▸DOB NOWOER: Notice to Proceed3
08/13/2026X07998676-I1Open ↗
08/13/2026X00893445-S1Open ↗
08/13/2026X00893445-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
06/29/2018220646665Open ↗
06/08/2016220535534Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
06/29/2018220646665Open ↗
▸DOB NOWOER: Notice of Satisfaction1
08/13/2026X07998676-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
▸BISTECHNICAL REPORT: ENERGY1
04/08/2011220111590Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/09/2018220646665Open ↗
▸Approvals, Objections & Sign-offs9
▸BISADMINISTRATIVE OBJECTIONS6
04/08/2011220111590Open ↗
03/14/2011220107845Open ↗
10/20/2009220032916Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/08/2016220535534Open ↗
12/02/2009220032916Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/02/2009220032916Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT8
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
04/08/2011220111590Open ↗
Showing 3 of 8 on file for this type
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET6
05/09/2018220646665Open ↗
06/08/2016220535534Open ↗
04/08/2011220111590Open ↗
Showing 3 of 6 on file for this type
▸Other Documents1
▸BISECCCNYS Analysis1
04/08/2011220111590Open ↗