| Owner | Filings | Most Recent |
|---|---|---|
| HRA | 12 | 03/21/2026 |
| City of NY Hra Ehcci | 6 | 03/21/2026 |
| DPT of Design Construction | 2 | 03/21/2026 |
| Acacia Gardens | 1 | 03/21/2026 |
| Hra East Harlem Multi Service CTR | 1 | 03/21/2026 |
| NYC Department of Housing Preservation and Development | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Exdem Engineering Services | 1 | 09/18/2026 |
| Dagher Engineering | 6 | 09/03/2026 |
| Paul A. Castrucci, Architect | 3 | 06/04/2026 |
| Geodesign | 2 | 02/25/2026 |
| Silman | 4 | 09/11/2025 |
| Langan Engineering | 1 | 06/11/2025 |
| MW Wellet Engineering | 2 | 11/16/2022 |
| Fox Architectural Design | 1 | 11/15/2022 |
| Michael Wein, PE | 1 | 02/16/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| William Vitacco Associates | 9 | 03/21/2026 |
| Municipal Building Consultants | 3 | 03/21/2026 |
| Stacie Scorcia Company | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Sigma Electric | Electrical | 1 | 03/21/2026 |
| D & S Electrical | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Metric Consulting and Ins | 1803 | 1 | 09/18/2026 |
| PSI Agency | 254 | 2 | 11/16/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | — | ISSUED | Lettire Construction | 11/15/2017 |
| BIS | EQ | ISSUED | Lettire Construction | 11/15/2017 |
| BIS | — | ISSUED | Lettire Construction | 11/14/2016 |
| BIS | PL | ISSUED | RO-Sal Plumbing & Heating | 05/19/2016 |
| BIS | — | ISSUED | Lettire Construction | 03/11/2016 |
| BIS | EQ | ISSUED | Lettire Construction | 03/11/2016 |
| BIS | OT | ISSUED | Duggan & Son Construction | 02/19/2015 |
| BIS | — | ISSUED | Prince Contracting | 08/19/2014 |
| BIS | OT | ISSUED | Prince Contracting | 06/06/2014 |
| BIS | PL | ISSUED | Jodian PL & Heating | 06/20/2000 |
| BIS | SP | ISSUED | Allstate Sprinkler | 07/14/1999 |
| BIS | EQ | ISSUED | MB Waterproofing | 06/03/1999 |
| BIS | EQ | ISSUED | MB Waterproofing | 03/31/1999 |
| BIS | EQ | ISSUED | Atlantic Heydt Scaffold | 03/17/1999 |
| BIS | PL | ISSUED | Jodian PL & Heating | 03/01/1999 |
| BIS | — | ISSUED | Positive Electric Associates | 01/25/1999 |
| BIS | OT | ISSUED | Metropolitan Hospital | 08/14/1997 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/18/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PURY-EP72TNU-A1 72,000 BTU · Vrf Outdoor ×18 PURY-EP96TNU-A1 96,000 BTU · Vrf Outdoor ×4 PKA-A24KA4 26,000 BTU · Vrf Indoor ×2 PUHY-EP144TNU-A1 144,000 BTU · Vrf Outdoor ×2 PUZ-A24NHA4 26,000 BTU · Condensing Unit ×2 MXR-SM36NAMHZ2-U1 36,000 BTU · Heat Pump Outdoor ×1 MXR-SM48NAM2-U1 48,000 BTU · Heat Pump Outdoor ×1 MXR-SM60NAM2-U1 60,000 BTU · Vrf Outdoor ×1 PUHY-EP192TNU-A1 192,000 BTU · Vrf Outdoor ×1 PUHY-EP240TNU-A1 240,000 BTU · Vrf Outdoor ×1 |
| 09/03/2026 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PEFY-P36NMHU-E2 36,000 BTU · Vrf Indoor ×3 PEFY-P48NMHU-E2 48,000 BTU · Vrf Indoor ×3 PKA-A24KA4 24,000 BTU · Vrf Indoor ×3 PUHY-EP120TNU-A1 120,000 BTU · Vrf Outdoor ×3 PUZ-A24NHA4 24,000 BTU · Condensing Unit ×3 PEFY-P12NMAU-E4 12,000 BTU · Vrf Indoor ×2 PEFY-P18NMHU-E2 18,000 BTU · Vrf Indoor ×2 PURY-EP72TNU-A 72,000 BTU · Vrf Outdoor ×2 PEFY-P08NMAU-E4 8,000 BTU · Vrf Indoor ×1 PEFY-P15NMAU-E4 15,000 BTU · Vrf Indoor ×1 PEFY-P15NMHU-E4 15,000 BTU · Vrf Indoor ×1 PEFY-P27NMHU-E2 27,000 BTU · Vrf Indoor ×1 Ventilation Swegon CASA R4-C GENIUS 155 CFM · Erv ×3 NAGOLD020FRX 2,860 CFM · Rooftop Unit ×2 NAGOLD030FRX 5,957 CFM · Rooftop Unit ×2 NAGOLD005FRX 360 CFM · Rooftop Unit ×1 NAGOLD012FRX 2,574 CFM · Rooftop Unit ×1 Enervex BEF560X 5,100 CFM · Exhaust Fan ×2 Greenheck AX-90-275-0614-B20 16,253 CFM · Exhaust Fan ×2 |
| 11/16/2022 | — | — | Air Conditioning Systems | Cooling |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2026 | — | — | Sprinkler System |
| 09/03/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2026 | — | — | Storm, Water/Sanitary |
| 09/03/2026 | — | — | Storm, Water/Sanitary |
| 11/16/2022 | — | — | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/18/2026 | — | — | Steel, Concrete, Masonry |
| 09/03/2026 | — | — | Steel, Concrete |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/18/2026 | Structural Steel - Details | — | special |
| 09/15/2026 | Demolition | — | special |
| 09/15/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 09/15/2026 | Construction Operations Influencing Adjacent Structures | — | special |
| 09/14/2026 | Final | — | progress |
| 09/14/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 07/20/2026 | Electrical motors and elevators | — | energy_progress |
| 07/20/2026 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 07/20/2026 | HVAC-R and service water heating system controls | — | energy_progress |
| 07/20/2026 | Energy Code Compliance Inspections | — | progress |
| 07/20/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 07/20/2026 | Maintenance information | — | energy_progress |
| 07/20/2026 | HVAC-R and service water heating equipment | — | energy_progress |
| 05/06/2026 | Electrical motors and elevators | — | energy_progress |
| 05/06/2026 | Lighting controls | — | energy_progress |
| 05/06/2026 | Metering | — | energy_progress |
| 05/06/2026 | Lighting in dwelling units | — | energy_progress |
| 05/06/2026 | Exterior lighting power | — | energy_progress |
| 05/06/2026 | Maintenance information | — | energy_progress |
| 05/06/2026 | Interior lighting power | — | energy_progress |
| 03/12/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 02/27/2026 | Public Assembly Emergency Lighting | paul castrucci | progress |
| 01/16/2026 | Energy Code Compliance Inspections | — | progress |
| 01/16/2026 | Fire-Resistance Rated Construction | — | progress |
| 01/16/2026 | Fire-Resistant Penetrations and Joints | — | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| The Beacon Community Facility | Community Facility | Cellar, Floors 1–6, Roof | Project M01365466 Project M01030184 Project M01031445 |
| Goodwill NY/NJ | Office | Floor 1 | Project M08027764 Project M08027770 Project M08026031 |