← Back
Two family converted from one family
414 BEACH 27 STREET
QUEENS · Far Rockaway-Bayswater · BIN 4301435
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R4AZoning
1,768 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 3,600 sf lot · 0.49 FAR built · Flood zone AE
Locations of Work
Architecture
Cellar1p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DOYUN KIM; RA203/11/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KC EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EMPIRE GROUP NYC LLCGeneral Contractor303/21/2026
CAPE PLUMBING INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415103/08/2021
Building Lifecycle
All (11)Filed (2)Permit Issued (3)Signed Off (2)Violation (2)Inspection (2)
07/07/2021
Signed off — Alteration
FILING TO RESTORE PREMISES TO PRIOR LEGAL CONDITION BY REMOVING PL FIXTURES
Q00478518-I1
06/29/2021
Signed off — Alteration
Q00478512-I1
06/25/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/24/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/08/2021
Permit issued — Plumbing
Q00478518-I1-PL
05/05/2021
Permit issued — Plumbing
Q00478518-I1-PL
03/11/2021
Filed — Alteration
FILING TO RESTORE PREMISES TO PRIOR LEGAL CONDITION BY REMOVING PL FIXTURES
Q00478518-I1
03/11/2021
Permit issued — General Construction
Q00478512-I1-GC
03/08/2021
Filed — Alteration
Q00478512-I1
01/31/2011
Violation issued (ECB, closed)
Construction
01/31/2011
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCAPE PLUMBING INC06/08/2021
DOB NOWPlumbingSigned-offCAPE PLUMBING INC05/05/2021
DOB NOWGeneral ConstructionSigned-offEMPIRE GROUP NYC LLC03/11/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/25/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/24/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00478512-I1Request digital key ↗
08/27/2026Q00478518-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00478512-I1Open ↗
08/27/2026Q00478518-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00478512-I1Open ↗
08/27/2026Q00478518-I1Open ↗