← Back
Old law tenement
416 LORIMER STREET
BROOKLYN · BIN 3327871
💬 Discuss this project
1930Year Built
3Stories
C4Building Class
R6BZoning
4,720 sfGross Floor Area
7Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Old law tenement · 2,600 sf lot · 1.82 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction14p · 1 filing · 20 docs
Floor 1Under Construction10p · 1 filing · 20 docs
CellarUnder Construction14p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LORIMER APARTMENTS LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/09/2025$2.0M—— → —$424/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BEAM ARCHITECTS D.P.C.308/10/2026
FL&M ENGINEERING DESIGN &INSPECTION106/19/2026
DNB ENGINEERING PLLC112/26/2025
JRS CONSULTING212/24/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STATELINE BUILDERS INCGeneral Contractor404/09/2026
ALL PRO PLBG & HTG INCFire Protection107/08/2026
A & H INSTALLATION INCGeneral Contractor106/28/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616508/10/2026
Building Lifecycle
All (105)Filed (7)Permit Issued (7)Signed Off (5)Violation (13)Inspection (11)Objection (32)Special Inspection (30)
09/14/2026
Signed off — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S1
08/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/19/2026
Signed off — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S3
08/18/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Permanent certificate
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
08/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
08/10/2026
Filed — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-P1
08/07/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Permanent certificate
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
08/07/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
08/04/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/27/2026
Signed off — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S5
07/27/2026
Signed off — Alteration
INSTALLATION OF OVERHEAD PROTECTION AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B01417502-I1
07/23/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
07/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/21/2026
Signed off — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S4
07/14/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
06/22/2026
Permit issued — Protection and Mechanical Methods
B01417502-I1-PMM
06/19/2026
Filed — Alteration
INSTALLATION OF OVERHEAD PROTECTION AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B01417502-I1
05/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/01/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/28/2026
Violation issued (ECB, closed)
Unknown
04/27/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/27/2026
Permit issued — Construction Fence
B01289763-S5-FN
03/26/2026
Filed — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S5
03/09/2026
Permit issued — Sprinklers
B01289763-S1-EW-SP
03/09/2026
Permit issued — Plumbing
B01289763-S1-PL
02/27/2026
Permit issued — General Construction
B01289763-I1-GC
02/19/2026
Objection raised — Other
02/19/2026
Objection resolved — Addressed
02/09/2026
Permit issued — Mechanical Systems
B01289763-S3-MS
02/05/2026
Permit issued — Structural
B01289763-S4-ST
02/05/2026
Objection resolved — Addressed
02/05/2026
Objection resolved — Addressed
01/22/2026
Objection raised — Other
01/22/2026
Objection resolved — Addressed
01/21/2026
Objection raised — Other
01/21/2026
Objection resolved — Addressed
01/13/2026
Special inspection requirement — Ventilation and air distribution system
SHAHRIAR QUAYYUM
01/06/2026
Objection raised — Cost
12/30/2025
Objection resolved — Addressed
12/26/2025
Filed — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S4
12/24/2025
Filed — Alteration CO
Plumbing and Sprinkler work filed subsequent to Alt CO application # B01289763-I1
B01289763-S1
Latest 60 of 105 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWProtection and Mechanical MethodsSigned-offA & H INSTALLATION INC06/22/2026
DOB NOWConstruction FenceSigned-offSTATELINE BUILDERS INC03/27/2026
DOB NOWSprinklersSigned-offALL PRO PLBG & HTG INC03/09/2026
DOB NOWPlumbingSigned-offALL PRO PLBG & HTG INC03/09/2026
DOB NOWGeneral ConstructionPermit IssuedSTATELINE BUILDERS INC02/27/2026
DOB NOWMechanical SystemsSigned-offSTATELINE BUILDERS INC02/09/2026
DOB NOWStructuralSigned-offSTATELINE BUILDERS INC02/05/2026
1 job · most recent 08/10/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/10/2026Signed-offSTATELINE BUILDERS INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAM2 36,000 BTU · Condensing Unit ×1
MXZ-SM42NAMHZ 42,000 BTU · Condensing Unit ×1
MXZ-SM48NAM2 48,000 BTU · Condensing Unit ×1
— MXZ-SM36NAM2 36,000 BTU · Condensing Unit ×1
1 job · most recent 08/10/2026
Sprinkler System
FiledStatusContractorScope
08/10/2026Signed-offALL PRO PLBG & HTG INCSprinkler System
1 job · most recent 08/10/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/10/2026Signed-offALL PRO PLBG & HTG INCStorm, Water/Sanitary
3 jobs · most recent 08/31/2026
General Wiring
FiledStatusContractorScope
08/31/2026CompleteRONEY ELECTRIC INCGeneral Wiring
12/15/2025CompleteRONEY ELECTRIC INCGeneral Wiring
12/10/2025CompleteRONEY ELECTRIC INC—
1 job · most recent 08/10/2026
Wood
FiledStatusContractorScope
08/10/2026Signed-offSTATELINE BUILDERS INCWood
1 job · most recent 08/10/2026
Fence
FiledStatusContractorScope
08/10/2026Signed-offSTATELINE BUILDERS INCFence
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
08/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/18/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/04/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/23/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/14/2026Fail-Final CND-Occupancy InspectionFailView ↗
05/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/01/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/27/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/27/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
08/12/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/12/2026Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
08/12/2026MeteringSHAHRIAR QUAYYUMenergy_progress
08/12/2026Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
08/12/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/12/2026Insulation placement and R valuesSHAHRIAR QUAYYUMenergy_progress
08/12/2026Permanent certificateSHAHRIAR QUAYYUMenergy_progress
08/12/2026Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
08/12/2026Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
08/12/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
08/07/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/07/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/07/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
08/07/2026Permanent certificateSHAHRIAR QUAYYUMenergy_progress
08/07/2026Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
08/07/2026Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
08/07/2026Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
08/07/2026Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
08/07/2026Insulation placement and R valuesSHAHRIAR QUAYYUMenergy_progress
08/07/2026MeteringSHAHRIAR QUAYYUMenergy_progress
01/13/2026Ventilation and air distribution systemSHAHRIAR QUAYYUMenergy_progress
12/21/2025Wood – Prefabricated I-JoistsSHAHRIAR QUAYYUMspecial
12/21/2025Post-installed AnchorsSHAHRIAR QUAYYUMspecial
12/18/2025FinalSHAHRIAR QUAYYUMprogress
12/18/2025Post-installed AnchorsSHAHRIAR QUAYYUMspecial
Latest 25 of 40.
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/19/2026B01289763-S1Request digital key ↗
08/19/2026B01289763-P1Request digital key ↗
08/19/2026B01289763-S5Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature9
08/28/2026B01289763-I1Open ↗
08/28/2026B01289763-I1Open ↗
08/28/2026B01289763-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/19/2026B01289763-S4Open ↗
08/19/2026B01289763-S1Open ↗
08/19/2026B01289763-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/28/2026B01289763-I1Open ↗
08/28/2026B01289763-S1Open ↗
08/25/2026B01289763-S4Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/19/2026B01289763-P1Open ↗
08/15/2026B01289763-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/19/2026B01289763-S1Open ↗
08/19/2026B01289763-P1Open ↗
08/19/2026B01289763-S5Open ↗
Showing 3 of 6 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/19/2026B01289763-P1Open ↗
08/15/2026B01289763-I1Open ↗