← Back
Two stories - detached, small or mid-size
418 APPLEGATE COURT
BROOKLYN · BIN 3190346
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R4-1Zoning
1,036 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 1,840 sf lot · 0.56 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 6 docs
Floor 13p · 2 filings · 10 docs
Cellar2p · 2 filings · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/27/2022$995K—BISHOP ESTATES LLC → Private party$960/sf building
06/02/2022$690K—Private party → BISHOP ESTATES LLC$666/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUST CONSULTING ENGINEERING409/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor107/08/2026
S & L PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G ENGINEERING PC7778209/06/2022
Building Lifecycle
All (18)Filed (4)Permit Issued (2)Signed Off (2)Inspection (7)Special Inspection (3)
12/23/2022
Signed off — Alteration
B00729333-I1
12/06/2022
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00729321-I1
12/05/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/01/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/28/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/03/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
09/07/2022
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
09/07/2022
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
09/06/2022
Filed — Alteration
B00729333-P1
09/06/2022
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00729321-P1
08/05/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/01/2022
Permit issued — Plumbing
B00729333-I1-PL
06/08/2022
Permit issued — General Construction
B00729321-I1-GC
06/03/2022
Filed — Alteration
B00729333-I1
06/03/2022
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00729321-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offS & L PLUMBING INC07/01/2022
DOB NOWGeneral ConstructionSigned-offSPLEN CONSTRUCTION INC06/08/2022
1 project · most recent 07/20/2022
General Wiring
FiledStatusContractorScope
07/20/2022CompleteERIC & NG ELEC'L, INC.General Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
12/05/2022Pass-Final General Construction Non-Directive 14PassView ↗
12/01/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/28/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2022Fail-Final General Construction Non-Directive 14FailView ↗
08/05/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/05/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/05/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
09/07/2022Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
09/07/2022Fire-Resistance Rated ConstructionXIONGCAI GUprogress
09/07/2022Energy Code Compliance InspectionsXIONGCAI GUprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/29/2026B00729321-P1Request digital key ↗
08/29/2026B00729321-I1Request digital key ↗
08/29/2026B00729333-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/29/2026B00729321-P1Open ↗
08/29/2026B00729321-I1Open ↗
08/29/2026B00729333-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026B00729321-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00729321-I1Open ↗