← Back
BuildNYC
City residence, one family
418 BAY RIDGE PARKWAY
BROOKLYN · Bay Ridge · BIN 3148755
💬 Discuss this project
1913Year Built
2Stories
A4Building Class
R5BZoning
1,924 sfGross Floor Area
1Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
City residence, one family · 2,000 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1p · 1 filing · 10 docs
Floor 213p · 2 filings · 20 docs
Floor 113p · 2 filings · 20 docs
Basement8p · 2 filings · 20 docs
Sub-Basement7p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
We Nailed It1607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/02/2025$1.9M—We Nailed-It → Private party$1,014/sf building
03/21/2022$810K—Private party → We Nailed-It$421/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JBA202/07/2025
Chun Engineering Consultant105/04/2024
Doyun Kim; RA203/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Javith Camino503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Joseph Weinstein ElectricElectrical103/22/2026
NYC Building SolutionsGeneral Contractor107/08/2026
All Pro Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Doyun Kim; RA7415302/07/2025
World Design Architecture9323105/04/2024
Building Lifecycle
07/18/2025
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B01034670-I1-GC
03/20/2025
Signed off — Alteration
HEREWITH FILING OT PROPOSE PLUMBING SYSTEMS AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB NOW # B01034670-I1.
B00773744-I1
02/26/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
DOYUN KIM
02/07/2025
Filed — Alteration
HEREWITH FILING OT PROPOSE PLUMBING SYSTEMS AS PER CONSTRUCTION PLANS. IN CONJUNCTION WITH DOB NOW # B01034670-I1.
B00773744-P1
70 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNYC Building Solutions07/18/2024
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating01/03/2024
1 project · most recent 03/05/2025
General Wiring
FiledStatusContractorScope
03/05/2025CompleteJoseph Weinstein ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/26/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/20/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/20/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
09/18/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/18/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
02/26/2025Fire-Resistant Penetrations and JointsDOYUN KIMspecial
02/06/2025Fire-Resistant Penetrations and JointsDOYUN KIMspecial
04/24/2024Fenestration and door U-factor and product ratingsWilliam Aliceaenergy_progress
04/24/2024Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
04/24/2024Energy Code Compliance InspectionsWilliam Aliceaprogress
04/24/2024Fire-Resistance Rated ConstructionWilliam Aliceaprogress
04/24/2024Fenestration areasWilliam Aliceaenergy_progress
04/24/2024Lighting in dwelling unitsWilliam Aliceaenergy_progress
04/24/2024Interior lighting powerWilliam Aliceaenergy_progress
04/24/2024Insulation placement and R valuesWilliam Aliceaenergy_progress
04/24/2024Fenestration air leakageWilliam Aliceaenergy_progress
04/24/2024Maintenance informationWilliam Aliceaenergy_progress
04/24/2024Lighting controlsWilliam Aliceaenergy_progress
04/24/2024Permanent certificateWilliam Aliceaenergy_progress
04/11/2024Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
09/07/2022Structural Stability – Alterations of existing buildingsDOYUN KIMspecial
09/07/2022Fire-Resistant Penetrations and JointsDOYUN KIMspecial
09/07/2022Energy Code Compliance InspectionsDOYUN KIMprogress
09/07/2022Fire-Resistance Rated ConstructionDOYUN KIMprogress
09/07/2022Fenestration areasDOYUN KIMenergy_progress
09/07/2022Fenestration air leakageDOYUN KIMenergy_progress
09/07/2022Lighting in dwelling unitsDOYUN KIMenergy_progress
09/07/2022Interior lighting powerDOYUN KIMenergy_progress
09/07/2022Insulation placement and R valuesDOYUN KIMenergy_progress
09/07/2022Fenestration and door U-factor and product ratingsDOYUN KIMenergy_progress
Latest 25 of 29.
30 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account