1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Auto body / collision or auto repair · Owner of record: GOTLIEB & SABBAGH REALTY · 10,000 sf lot · 1.83 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof2p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BAY RIDGE VOLVO AMERICAN INC.1507/08/2026
OWNER OF 419 90TH ST103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ANDREW KATZ ENGINEERS508/10/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
METRO MECHANICAL LLCGeneral Contractor307/08/2026
J.A. MECH. PLBG. & HTG INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KATZ, P.E.6087210/31/2022
Building Lifecycle
All (20)Filed (5)Permit Issued (3)Signed Off (3)Violation (1)Inspection (1)Special Inspection (7)
09/11/2023
Signed off — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-I1
08/21/2023
Signed off — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-S1
08/10/2023
Filed — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-P2
08/04/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/15/2023
Filed — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-P1
01/10/2023
Permit issued — Plumbing
B08023896-S1-PL
11/28/2022
Filed — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-S1
10/31/2022
Filed — Alteration
DISCONNECT AND RECONNECT EXISTING GAS PIPING TO ROOFTOP AC UNIT. MECHANICAL SYSTEMS WORKTYPE FILED UNDER B08023896-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B08023896-I1
10/31/2022
Permit issued — Mechanical Systems
B08023896-I1-MS
10/24/2022
Special inspection requirement — Heating Systems
David Katz
10/19/2022
Special inspection requirement — Energy Code Compliance Inspections
David Katz
10/19/2022
Special inspection requirement — Mechanical Systems
David Katz
10/19/2022
Special inspection requirement — HVAC-R and service water heating system controls
David Katz
10/19/2022
Special inspection requirement — HVAC-R and service water heating equipment
David Katz
10/19/2022
Special inspection requirement — Maintenance information
David Katz
10/19/2022
Special inspection requirement — Final
David Katz
01/27/2022
Signed off — Alteration
B00663859-I1
01/21/2022
Permit issued — Mechanical Systems
B00663859-I1-MS
01/20/2022
Filed — Alteration
B00663859-I1
09/27/1993
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJ.A. MECH. PLBG. & HTG IN01/10/2023
DOB NOWMechanical SystemsSigned-offMETRO MECHANICAL LLC10/31/2022
DOB NOWMechanical SystemsSigned-offMETRO MECHANICAL LLC01/21/2022
BISMHISSUEDDYNAMIC SHEET METAL LTD07/28/2004
BISOTISSUEDNATIONAL MAINTENANCE INC06/04/1999
BIS—ISSUEDNATIONAL MAINTENANCE INC06/04/1999
BISFBISSUEDS.J. FUEL CO., INC02/03/1994
BISEQISSUEDCUSTOM CRAFTSMAN OF BKLYN, INC.10/21/1993
2 projects · most recent 05/02/2024
General Wiring
FiledStatusContractorScope
05/02/2024Permit IssuedDAVEN ELECTRIC CORPGeneral Wiring
08/29/2019CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/04/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/24/2022Heating SystemsDavid Katzspecial
10/19/2022Energy Code Compliance InspectionsDavid Katzprogress
10/19/2022Mechanical SystemsDavid Katzspecial
10/19/2022HVAC-R and service water heating system controlsDavid Katzenergy_progress
10/19/2022HVAC-R and service water heating equipmentDavid Katzenergy_progress
10/19/2022Maintenance informationDavid Katzenergy_progress
10/19/2022FinalDavid Katzprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/31/2026B00663859-I1Request digital key ↗
08/27/2026B08023896-P2Request digital key ↗
08/27/2026B08023896-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/31/2026B00663859-I1Open ↗
08/27/2026B08023896-P1Open ↗
08/27/2026B08023896-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026B08023896-I1Open ↗
08/25/2026B08023896-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B08023896-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00663859-I1Open ↗