← Back
Two family converted from one family
419 EAST 141 STREET
BRONX · BIN 2000405
💬 Discuss this project
1910Year Built
2Stories
B3Building Class
R6Zoning
—Gross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 1.43 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 22p · 1 filing · 3 docs
Floor 12p · 1 filing · 3 docs
Cellar3p · 2 filings · 9 docs
Sub-Basement2p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ECLIPSE VETERINARY MANAGEMENT SERVI307/08/2026
OWNER REPRESENTATIVE307/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC104/01/2022
BUILD TECH CONSTRUCTION CORP102/21/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILD TECH CONSTRUCTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALEXANDRINI, VINCENTElectrical103/21/2026
BAIN, GElectrical103/21/2026
MERCURY PLBG & HTG COElectrical103/21/2026
SUMMERVILLE, ERROLElectrical103/21/2026
ADV NY INCGeneral Contractor107/08/2026
BUILD TECH CONSTRUCTION CORP.General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746104/01/2022
BUILD-TECH CONSTRUCTION612102/21/2020
Building Lifecycle
All (13)Filed (2)Permit Issued (2)Signed Off (1)Violation (5)Special Inspection (3)
05/10/2022
Signed off — Alteration
X00709830-I1
04/04/2022
Permit issued — Mechanical Systems
X00709830-I1-MS
04/01/2022
Filed — Alteration
X00709830-I1
03/31/2022
Special inspection requirement — Mechanical Systems
Stephen Shishko
03/31/2022
Special inspection requirement — Chimneys and vents
Stephen Shishko
03/31/2022
Special inspection requirement — Final
Stephen Shishko
04/21/2021
Violation issued (HPD, closed)
I
10/30/2020
Permit issued — Mechanical Systems
X00319142-I1-MS
02/21/2020
Filed — Alteration
installation of hvac air handlers and related duct work
X00319142-I1
12/17/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/15/2005
Violation issued (ECB, closed)
Construction
11/16/2005
Violation issued (ECB, closed)
Construction
11/16/2005
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offADV NY04/04/2022
DOB NOWMechanical SystemsPermit IssuedBUILD TECH CONSTRUCTION C10/30/2020
BISPLISSUEDINFINITI ESC PLUMBING COR03/31/2021
BISPLISSUEDINFINITI ESC PLUMBING COR01/17/2020
BIS—ISSUEDCHEEMA CONSTRUCTION INC12/05/2019
BIS—ISSUEDCHEEMA CONSTRUCTION INC06/19/2019
1 project · most recent 02/21/2020
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/21/2020Permit IssuedBUILD TECH CONSTRUCTION CAir Conditioning Systems, Ventilation Systems
Cooling
Comfortmaker B77316N4A 7 tons · Condensing Unit ×2
Ventilation
Comfort Aire WCG36TOA 7 tons · Ahu ×2
1 project · most recent 08/13/2019
General Wiring
FiledStatusContractorScope
08/13/2019CompleteFOSTER ELEC'L SVC., INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
03/31/2022Mechanical SystemsStephen Shishkospecial
03/31/2022Chimneys and ventsStephen Shishkospecial
03/31/2022FinalStephen Shishkoprogress
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/26/2026X00319142-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/24/2026X00709830-I1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION6
05/12/2021220665180Open ↗
04/22/2021220665180Open ↗
07/16/2020220665180Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
01/17/2020220665180Open ↗
12/05/2019220665180Open ↗
08/12/2019220665180Open ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
10/24/2024220665180Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/18/2019220665180Open ↗
12/19/2018220665180Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026X00319142-I1Open ↗
08/24/2026X00709830-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026X00709830-I1Open ↗
08/26/2026X00709830-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/19/2018220665180Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/19/2018220665180Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026X00709830-I1Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING3
04/22/2021220665180Open ↗
07/13/2020220665180Open ↗
07/09/2020220665180Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
12/19/2018220665180Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
06/19/2019220665180Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026X00319142-I1Open ↗
08/24/2026X00709830-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/19/2018220665180Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/18/2019220665180Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE1
12/19/2018220665180Open ↗
▸BISSUPERSEDING LETTER1
01/17/2020220665180Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/26/2020220665180Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/19/2018220665180Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
05/12/2021220665180Open ↗
07/16/2020220665180Open ↗
07/14/2020220665180Open ↗
▸BISEFILING COVER SHEET1
12/19/2018220665180Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
12/19/2018220665180Open ↗