← Back
Primarily 4 family with 1 store or office
42-04 108 STREET
QUEENS · Corona · BIN 4048872
💬 Discuss this project
1936Year Built
3Stories
S4Building Class
R6BZoning
3,180 sfGross Floor Area
5Units
Rent Stabilized6 Open Violations 4 unresolved · 2 paperwork only ▸
Primarily 4 family with 1 store or office · 2,500 sf lot · 1.27 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 11p · 1 filing · 5 docs
Filed — no permit issued2p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHON ENGINEERING211/10/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AVON PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHON ENGINEERING PC2454211/10/2020
Building Lifecycle
All (38)Filed (2)Permit Issued (1)Violation (29)Special Inspection (6)
05/07/2026
Violation issued (HPD, closed)
A
06/12/2025
Violation issued (HPD, closed)
A
04/15/2024
Violation issued (HPD, closed)
A
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/28/2023
Violation issued (HPD, closed)
A
03/04/2022
Violation issued (HPD, closed)
A
04/15/2021
Violation issued (HPD, closed)
A
04/15/2021
Violation issued (HPD, closed)
I
01/13/2021
Permit issued — Plumbing
Q00425686-I1-PL
11/10/2020
Filed — Alteration
to install 5 ton hvac unit for existing laundry
Q00426020-I1
11/10/2020
Special inspection requirement — Mechanical Systems
Steve Chon
11/10/2020
Special inspection requirement — Final
Steve Chon
11/10/2020
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
11/10/2020
Special inspection requirement — HVAC and service water heating equipment
Steve Chon
11/10/2020
Special inspection requirement — HVAC and service water heating system controls
Steve Chon
11/09/2020
Filed — Alteration
TO REPLACE WASHERS AND DRYERS FOR EXISTING LAUNDRY
Q00425686-I1
11/09/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
11/01/2019
Violation issued (HPD, closed)
I
11/18/2016
Violation issued (HPD, closed)
I
04/20/2016
Violation issued (HPD, open)
B
02/27/2015
Violation issued (HPD, closed)
I
11/24/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/30/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/09/2011
Violation issued (ECB, open)
Plumbing
09/09/2011
Violation issued (ECB, open)
Plumbing
11/15/2005
Violation issued (ECB, closed)
Construction
09/08/2004
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAVON PLBG & HTG INC01/13/2021
BISOTISSUEDSTELLAR INDUSTRIES INC01/07/2021
BISOTISSUEDSTELLAR INDUSTRIES INC11/06/2020
BISPLISSUEDROCK E SMALL PLBG&HTG INC06/22/2012
BISPLISSUEDPRECISION PLBG SVCS., INC06/21/2012
1 project · most recent 11/10/2020
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/10/2020——Air Conditioning Systems, Ventilation Systems
Cooling
York TCGD60D4153A 2,000 CFM · Condensing Unit ×1
Ventilation
York F5FP060H06T3XH 2,000 CFM · Ahu ×1
1 project · most recent 11/09/2020
Gas Water/Sanitary
FiledStatusContractorScope
11/09/2020Permit IssuedAVON PLBG & HTG INCGas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
11/10/2020Mechanical SystemsSteve Chonspecial
11/10/2020FinalSteve Chonprogress
11/10/2020Energy Code Compliance InspectionsSteve Chonprogress
11/10/2020HVAC and service water heating equipment Steve Chonenergy_progress
11/10/2020HVAC and service water heating system controls Steve Chonenergy_progress
11/09/2020Fire-Resistant Penetrations and JointsSteve Chonspecial
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00425686-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/27/2026Q00426020-I1Request digital key ↗
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION6
10/27/2020440641995Open ↗
02/14/2018420505484Open ↗
11/22/2017420505484Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
11/06/2020440641995Open ↗
02/11/2013420505484Open ↗
06/27/2012420505484Open ↗
Showing 3 of 4 on file for this type
▸BISINTENT TO REVOKE APPROVAL/PERMIT1
04/13/2017420505484Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature4
08/29/2026Q00426020-I1Open ↗
08/29/2026Q00426020-I1Open ↗
08/29/2026Q00426020-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00425686-I1Open ↗
08/13/2026Q00426020-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00425686-I1Open ↗
08/29/2026Q00426020-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/27/2020440641995Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/27/2020440641995Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/27/2012420505484Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/27/2020440641995Open ↗
▸Trade Schedules & Equipment4
▸BISSELF-CERT PLUMBING NOTICE2
09/12/2013420505484Open ↗
07/03/2012420505484Open ↗
▸BISSCHEDULE B - PLUMBING2
07/19/2012420505484Open ↗
11/18/2011420505484Open ↗
▸Safety & Tenant Protection4
▸DOB NOWTenant Protection Plan2
08/13/2026Q00425686-I1Open ↗
08/13/2026Q00426020-I1Open ↗
▸BISSTREET TREE CHECKLIST1
11/18/2011420505484Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
10/27/2020440641995Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00425686-I1Open ↗
08/13/2026Q00426020-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
11/18/2011420505484Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/27/2020440641995Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
11/18/2011420505484Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/27/2020440641995Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE2
04/05/2012420505484Open ↗
11/18/2011420505484Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/23/2012420505484Open ↗
▸BISSUPERSEDING LETTER1
02/25/2013420505484Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
11/21/2011420505484Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/27/2020440641995Open ↗
11/18/2011420505484Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET1
11/21/2011420505484Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/27/2020440641995Open ↗
▸BISADDITIONAL INFORMATION1
02/14/2018420505484Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
11/18/2011420505484Open ↗