← Back
Office only, 2-6 stories
42-27 162 STREET
QUEENS · East Flushing · BIN 4447242
💬 Discuss this project
1996Year Built
2Stories
O2Building Class
R5BZoning
3,399 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Office only, 2-6 stories · Owner of record: 4227-29 162 LLC · 2,000 sf lot · 1.7 FAR built · Flood zone X
Locations of Work
Architecture
Cellar6p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
308 CORP.103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT211/22/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREAT ONE CONSTRUCTION LLGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513211/22/2024
Building Lifecycle
All (17)Filed (2)Permit Issued (1)Signed Off (1)Violation (3)Inspection (3)Objection (2)Special Inspection (5)
02/06/2025
Signed off — Alteration
INTERIOR RENOVATION FOR AN EXISTING OFFICE SPACE IN THE CELLAR. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
Q01096512-I1
02/05/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/21/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/16/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/22/2024
Filed — Alteration
INTERIOR RENOVATION FOR AN EXISTING OFFICE SPACE IN THE CELLAR. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
Q01096512-P1
11/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
11/21/2024
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
11/21/2024
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
11/21/2024
Special inspection requirement — Lighting controls
DEZHANG FANG
11/21/2024
Special inspection requirement — Interior lighting power
DEZHANG FANG
09/16/2024
Permit issued — General Construction
Q01096512-I1-GC
09/05/2024
Objection resolved — Addressed
08/26/2024
Objection raised — Other
08/19/2024
Filed — Alteration
INTERIOR RENOVATION FOR AN EXISTING OFFICE SPACE IN THE CELLAR. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
Q01096512-I1
09/16/2021
Violation issued (ECB, closed)
Construction
09/16/2021
Violation issued (ECB, closed)
Construction
09/16/2021
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offGREAT ONE CONSTRUCTION LL09/16/2024
BIS—ISSUEDSAME06/05/1996
BISPLISSUEDNORTON PLG09/18/1995
BIS—ISSUEDSAME08/11/1995
BISEQISSUEDSANO CONSTRUCTION CORP06/12/1995
BISEQISSUEDSANO CONSTRUCTION CORP06/12/1995
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/05/2025Pass-Final General Construction Non-Directive 14PassView ↗
01/21/2025Fail-Final General Construction Non-Directive 14FailView ↗
12/16/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/21/2024Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
11/21/2024Energy Code Compliance InspectionsDEZHANG FANGprogress
11/21/2024Fire-Resistance Rated ConstructionDEZHANG FANGprogress
11/21/2024Lighting controlsDEZHANG FANGenergy_progress
11/21/2024Interior lighting powerDEZHANG FANGenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01096512-I1Request digital key ↗
08/21/2026Q01096512-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01096512-P1Open ↗
08/21/2026Q01096512-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q01096512-P1Open ↗
08/25/2026Q01096512-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026Q01096512-P1Open ↗