| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/23/2024 | $1.2M | — | Private party → Private party | $661/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Prime Zone Building Consulting | 5 | 10/02/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| Prime Zone Building Consulting | 5 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| J S Remodeling NY | General Contractor | 3 | 03/21/2026 |
| K & BH Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Lam and Co Consulting | 8864 | 3 | 10/02/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | K & BH Plumbing & Heating | 06/24/2024 |
| DOB NOW | General Construction | Signed-off | J S Remodeling NY | 06/03/2024 |
| BIS | OT | ISSUED | Same | 07/08/2005 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/06/2024 | Complete | A Electrical Main Service | 3 meters, 3 new_meters |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/09/2024 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 10/01/2024 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 09/30/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 09/19/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/06/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/02/2024 | Fenestration and door U-factor and product ratings | JICHEN SUN | energy_progress |
| 10/02/2024 | Fenestration areas | JICHEN SUN | energy_progress |
| 10/02/2024 | Interior lighting power | JICHEN SUN | energy_progress |
| 10/02/2024 | Air barrier - visual inspection | JICHEN SUN | energy_progress |
| 10/02/2024 | Fenestration air leakage | JICHEN SUN | energy_progress |
| 10/02/2024 | Energy Code Compliance Inspections | JICHEN SUN | progress |
| 10/02/2024 | Fire-Resistant Penetrations and Joints | JICHEN SUN | special |
| 09/18/2024 | Fire-Resistant Penetrations and Joints | JICHEN SUN | special |
| 09/18/2024 | Energy Code Compliance Inspections | JICHEN SUN | progress |
| 09/18/2024 | Fenestration air leakage | JICHEN SUN | energy_progress |
| 09/18/2024 | Fenestration and door U-factor and product ratings | JICHEN SUN | energy_progress |
| 09/18/2024 | Air barrier - visual inspection | JICHEN SUN | energy_progress |
| 09/18/2024 | Interior lighting power | JICHEN SUN | energy_progress |
| 09/18/2024 | Fenestration areas | JICHEN SUN | energy_progress |
| 07/26/2024 | Energy Code Compliance Inspections | JICHEN SUN | progress |
| 07/26/2024 | HVAC-R and service water piping design and insulation | JICHEN SUN | energy_progress |
| 07/26/2024 | HVAC-R and service water heating equipment | JICHEN SUN | energy_progress |
| 07/26/2024 | HVAC-R and service water heating system controls | JICHEN SUN | energy_progress |
| 07/22/2024 | HVAC-R and service water heating system controls | JICHEN SUN | energy_progress |
| 07/22/2024 | HVAC-R and service water piping design and insulation | JICHEN SUN | energy_progress |
| 07/22/2024 | HVAC-R and service water heating equipment | JICHEN SUN | energy_progress |
| 07/22/2024 | Energy Code Compliance Inspections | JICHEN SUN | progress |