← Back
General warehouse
42 BRIDGEWATER STREET
BROOKLYN · Greenpoint · BIN 3066694
💬 Discuss this project
1931Year Built
2Stories
E1Building Class
M3-1Zoning
80,585 sfGross Floor Area
1Units
LL97 Covered2 Open Violations ▸FDNY Report ↗
General warehouse · Owner of record: PEERLESS EQUITIES LLC · 68,774 sf lot · 1.17 FAR built · Flood zone X
Locations of Work
Architecture
Site & exterior1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
181 LAWRENCE AVE REALTY503/21/2026
PEERLESS EQUITIES303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MULLEN PALANDRANI ARCHITECTS103/28/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
3 L. BROS. CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMKA & ASSOCIATES LLC8239103/28/2023
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Objection (2)Special Inspection (2)
07/21/2023
Signed off — Alteration
REPAIR EXISTING FACE BRICK AT EXISTING BRICK WALL. FILING TO RESOLVE ECB VIOLATION #39512985X. NO CHANGE TO USE, EGRESS, OCCUPANCY, OR ZONING.
B00842071-I1
05/30/2023
Permit issued — General Construction
B00842071-I1-GC
04/05/2023
Objection resolved — Addressed
03/29/2023
Objection raised — Other
03/28/2023
Filed — Alteration
REPAIR EXISTING FACE BRICK AT EXISTING BRICK WALL. FILING TO RESOLVE ECB VIOLATION #39512985X. NO CHANGE TO USE, EGRESS, OCCUPANCY, OR ZONING.
B00842071-I1
03/10/2023
Special inspection requirement — Masonry
AHMAD KHANZADA
03/10/2023
Special inspection requirement — Final
Richard Palandrani
02/11/2023
Violation issued (ECB, closed)
Construction
12/01/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/01/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-off3 L BROS05/30/2023
BISFSISSUEDMICHAEL S. KAPLAN08/05/2014
BIS—ISSUEDRYDER CONSTRUCTION INC03/25/2004
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/10/2023MasonryAHMAD KHANZADAspecial
03/10/2023FinalRichard Palandraniprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B00842071-I1Request digital key ↗
▸Seals & Professional Certifications4
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION1
03/13/2015320886332Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00842071-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026B00842071-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026B00842071-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00842071-I1Open ↗
▸Energy Compliance2
▸BISTR8: Energy Code Progress Inspections1
03/13/2015320886332Open ↗
▸BISEN2 - As Built Energy Analysis1
03/13/2015320886332Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST1
03/13/2015320886332Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/13/2015320886332Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/13/2015320886332Open ↗