← Back
Miscellaneous two family
42 WEST 128 STREET
MANHATTAN · Harlem (North) · BIN 1053675
💬 Discuss this project
1899Year Built
3Stories
B9Building Class
R7-2Zoning
3,972 sfGross Floor Area
2Units
0 Open Violations
Miscellaneous two family · Owner of record: 1330 TELLER NY CORP. · 1,998 sf lot · 1.99 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction28p · 1 filing · 20 docs
Floor 2Under Construction27p · 1 filing · 20 docs
Floor 1Under Construction27p · 1 filing · 20 docs
CellarUnder Construction27p · 1 filing · 20 docs
Sub-BasementUnder Construction27p · 1 filing · 20 docs
Site & exteriorUnder Construction4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ATOMIC CONTRACTING2109/15/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/25/2025$1.0M—GEORGIA & JOSEPH SR. INC. → 1330 TELLER NY CORP.$261/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT408/31/2026
AGT ARCHITECTURE P.C.505/27/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FANG ARCHITECT403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DESIGNS INCGeneral Contractor504/09/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
RENEW PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513908/31/2026
Building Lifecycle
All (64)Filed (9)Permit Issued (4)Signed Off (1)Violation (2)Inspection (4)Objection (14)Special Inspection (30)
08/31/2026
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-P6
08/28/2026
Special inspection requirement — Structural Steel - Details
DEZHANG FANG
08/28/2026
Special inspection requirement — Concrete - Cast-In-Place
DEZHANG FANG
08/28/2026
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
08/28/2026
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
08/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
08/28/2026
Special inspection requirement — Fenestration air leakage
DEZHANG FANG
08/28/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
DEZHANG FANG
08/28/2026
Special inspection requirement — Footing and Foundation
DEZHANG FANG
08/28/2026
Special inspection requirement — Interior lighting power
DEZHANG FANG
08/28/2026
Special inspection requirement — Final
DEZHANG FANG
08/28/2026
Special inspection requirement — Air barrier - visual inspection
DEZHANG FANG
08/28/2026
Special inspection requirement — Insulation placement and R values
DEZHANG FANG
08/28/2026
Special inspection requirement — Fenestration areas
DEZHANG FANG
08/24/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/31/2026
Signed off — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-S2
07/04/2026
Objection resolved — Addressed
07/04/2026
Objection resolved — Addressed
06/26/2026
Objection raised — Scope
06/26/2026
Objection raised — Scope
05/27/2026
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-P4
05/27/2026
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-P3
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
05/27/2026
Special inspection requirement — Duct leakage testing, insulation and design
GE TANG
05/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GE TANG
05/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
GE TANG
05/27/2026
Special inspection requirement — Final
GE TANG
05/27/2026
Special inspection requirement — Energy Code Compliance Inspections
GE TANG
05/27/2026
Special inspection requirement — Mechanical Systems
DEZHANG FANG
05/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
GE TANG
05/27/2026
Special inspection requirement — Heating Systems
DEZHANG FANG
05/27/2026
Special inspection requirement — Maintenance information
GE TANG
05/13/2026
Violation issued (ECB, closed)
Construction
05/13/2026
Violation issued (ECB, closed)
Construction
04/15/2026
Special inspection requirement — Final
GE TANG
04/15/2026
Special inspection requirement — Energy Code Compliance Inspections
GE TANG
04/15/2026
Special inspection requirement — HVAC-R and service water heating system controls
GE TANG
04/15/2026
Special inspection requirement — Heating Systems
DEZHANG FANG
04/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
04/15/2026
Special inspection requirement — Mechanical Systems
DEZHANG FANG
04/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
GE TANG
03/16/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
02/06/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/05/2026
Objection raised — Other
02/05/2026
Objection raised — Zoning
01/21/2026
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-P1
01/21/2026
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-P2
12/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/15/2025
Permit issued — Mechanical Systems
M01293348-S3-MS
12/15/2025
Permit issued — Plumbing
M01293348-S2-PL
12/12/2025
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-S2
12/12/2025
Filed — Alteration
FILED PLUMBING WORK FOR AN EXIST. 4-STORY 2-FAMILY BUILDING. NO CHANGE TO EXIST. USE, EGRESS & OCCUPANCY.
M01293348-S3
12/08/2025
Permit issued — Foundation
M01293348-I1-GC-CX
12/02/2025
Objection resolved — Addressed
11/07/2025
Objection resolved — Addressed
11/07/2025
Objection resolved — Addressed
10/02/2025
Permit issued — General Construction
M01293348-S1-GC
10/01/2025
Objection raised — Scope
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedJ&J DESIGNS INC12/15/2025
DOB NOWPlumbingSigned-offRENEW PLUMBING CORP12/15/2025
DOB NOWFoundationPermit IssuedJ&J DESIGNS INC12/08/2025
DOB NOWGeneral ConstructionSigned-offJ&J DESIGNS INC10/02/2025
1 project · most recent 08/31/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/31/2026Permit IssuedJ&J DESIGNS INCHeating and Air Conditioning Systems
Heat / Cool
Cooper & Hunter MODEL: CH-RHP24-230VO 26,000 BTU · Condensing Unit ×4
MODEL: CH-RHP28M-230VO 27,000 BTU · Condensing Unit ×2
1 project · most recent 08/31/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/31/2026Signed-offRENEW PLUMBING CORPGas, Storm, Water/Sanitary
1 project · most recent 06/17/2026
General Wiring
FiledStatusContractorScope
06/17/2026CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 08/31/2026
Steel
FiledStatusContractorScope
08/31/2026Permit IssuedJ&J DESIGNS INCSteel
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/24/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/06/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/31/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 73
DateRequirementInspectorRole
08/28/2026Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
08/28/2026Interior lighting powerDEZHANG FANGenergy_progress
08/28/2026Fenestration air leakageDEZHANG FANGenergy_progress
08/28/2026Air barrier - visual inspectionDEZHANG FANGenergy_progress
08/28/2026Fenestration areasDEZHANG FANGenergy_progress
08/28/2026Insulation placement and R valuesDEZHANG FANGenergy_progress
08/28/2026Concrete - Cast-In-PlaceDEZHANG FANGspecial
08/28/2026Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
08/28/2026Structural Steel - DetailsDEZHANG FANGspecial
08/28/2026Energy Code Compliance InspectionsDEZHANG FANGprogress
08/28/2026FinalDEZHANG FANGprogress
08/28/2026Fire-Resistance Rated ConstructionDEZHANG FANGprogress
08/28/2026Footing and FoundationDEZHANG FANGprogress
05/27/2026Duct leakage testing, insulation and designGE TANGenergy_progress
05/27/2026Maintenance informationGE TANGenergy_progress
05/27/2026HVAC-R and service water heating equipmentGE TANGenergy_progress
05/27/2026Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
05/27/2026Heating SystemsDEZHANG FANGspecial
05/27/2026Mechanical SystemsDEZHANG FANGspecial
05/27/2026Energy Code Compliance InspectionsGE TANGprogress
05/27/2026FinalGE TANGprogress
05/27/2026HVAC-R and service water heating system controlsGE TANGenergy_progress
05/27/2026HVAC-R and service water piping design and insulationGE TANGenergy_progress
04/15/2026Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
04/15/2026Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
Latest 25 of 73.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/20/2026M01293348-P4Request digital key ↗
08/20/2026M01293348-P2Request digital key ↗
08/20/2026M01293348-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
09/15/2026M01293348-P6Open ↗
08/20/2026M01293348-I1Open ↗
08/14/2026M01293348-P3Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications33
▸DOB NOWProgress Inspector Seal & Signature14
09/23/2026M01293348-P6Open ↗
09/23/2026M01293348-P6Open ↗
09/23/2026M01293348-S3Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/15/2026M01293348-P5Open ↗
09/15/2026M01293348-P6Open ↗
08/20/2026M01293348-S2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/23/2026M01293348-P6Open ↗
09/23/2026M01293348-P5Open ↗
09/23/2026M01293348-S3Open ↗
Showing 3 of 9 on file for this type
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
09/15/2026M01293348-P5Open ↗
09/15/2026M01293348-P6Open ↗
08/20/2026M01293348-S2Open ↗
Showing 3 of 10 on file for this type