| Owner | Filings | Most Recent |
|---|---|---|
| Ansonia Court Tenants | 15 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Julie Mee Schmidt Architecture | 2 | 03/19/2026 |
| EP Engineering | 11 | 03/03/2026 |
| City Building NY Architect | 1 | 02/12/2026 |
| Matthew Michalski | 3 | 10/30/2025 |
| Nikolai Katz Architect | 2 | 05/16/2024 |
| Millward Architecture Design | 2 | 11/06/2023 |
| Ronald D.victorio R.A | 4 | 01/31/2023 |
| E.G. Architecture | 1 | 05/03/2021 |
| Representative | Filings | Most Recent |
|---|---|---|
| Joseph Fellner | 1 | 03/21/2026 |
| Paul Fusco Consulting | 26 | 03/21/2026 |
| J A Expediting | 4 | 03/21/2026 |
| Millward Architecture Design | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| R&S Elite Construction | General Contractor | 8 | 07/08/2026 |
| HBH Construction | General Contractor | 7 | 06/28/2026 |
| Ice Age Mechanical | specialty_contractor | 7 | 04/09/2026 |
| Artur Kalaj | General Contractor | 3 | 03/21/2026 |
| M Interior Construction I | General Contractor | 2 | 07/08/2026 |
| Sunbird Electrical Contracting | Electrical | 1 | 03/22/2026 |
| Denmar Electric | Electrical | 1 | 03/21/2026 |
| A L Electrical | General Contractor | 1 | 03/22/2026 |
| R&R Contracting Management | General Contractor | 1 | 04/09/2026 |
| Yung Way Construction | General Contractor | 1 | 04/11/2026 |
| Pipestylists | Plumbing | 1 | 07/08/2026 |
| P.S.I. Mechanical | Plumbing | 1 | 03/22/2026 |
| A.L. Electrical | Electrical | 1 | 03/21/2026 |
| Safepipe Plumbing | Plumbing | 1 | 07/03/2026 |
| Denmar Electric | Electrical | 1 | 03/22/2026 |
| Lebo Electric | Electrical | 1 | 03/22/2026 |
| WCK Electric | Electrical | 1 | 03/21/2026 |
| Roger de Electric Co | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Chang Park Arch | 663 | 2 | 03/19/2026 |
| Catalpa Special Inspectio | 2004 | 7 | 03/03/2026 |
| City Building NY Architects | 1394 | 1 | 02/12/2026 |
| EP Inspections and Commis | 7079 | 5 | 06/09/2025 |
| Nikolai Katz Architect | 3482 | 1 | 05/16/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | Ice Age Mechanical | 10/21/2026 |
| DOB NOW | Plumbing | Signed-off | Safepipe Plumbing | 07/01/2026 |
| DOB NOW | General Construction | Signed-off | HBH Construction | 06/26/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | B & A Commercial | 04/09/2026 |
| DOB NOW | Mechanical Systems | Signed-off | R&S Elite Construction | 03/09/2026 |
| DOB NOW | Mechanical Systems | Signed-off | R&R Contracting Management | 12/02/2025 |
| DOB NOW | General Construction | Signed-off | R&S Elite Construction | 11/12/2025 |
| DOB NOW | Mechanical Systems | Signed-off | R&S Elite Construction | 11/12/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | Ice Age Mechanical | 11/05/2025 |
| DOB NOW | General Construction | Permit Issued | Ice Age Mechanical | 11/05/2025 |
| DOB NOW | Mechanical Systems | Signed-off | Ice Age Mechanical | 03/03/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | HBH Construction | 02/27/2025 |
| DOB NOW | Mechanical Systems | Signed-off | R&S Elite Construction | 10/15/2024 |
| DOB NOW | General Construction | Signed-off | R&S Elite Construction | 10/08/2024 |
| DOB NOW | Mechanical Systems | Signed-off | R&S Elite Construction | 10/08/2024 |
| DOB NOW | Mechanical Systems | Signed-off | M Interior Construction I | 03/11/2024 |
| DOB NOW | General Construction | Signed-off | M Interior Construction I | 08/28/2023 |
| DOB NOW | Plumbing | Signed-off | T & T Plumbing | 12/07/2022 |
| DOB NOW | General Construction | Permit Issued | HBH Construction | 10/13/2022 |
| DOB NOW | General Construction | Signed-off | Artur Kalaj | 05/10/2021 |
| BIS | OT | ISSUED | Artur Kalaj | 09/09/2020 |
| BIS | PL | ISSUED | Myrto Plumbing & HVAC | 08/03/2018 |
| BIS | OT | ISSUED | Artur Kalaj | 07/17/2018 |
| BIS | EQ | ISSUED | Gul & G Contracting | 06/21/2017 |
| BIS | PL | ISSUED | Top Dog Plumbing & Heating | 01/19/2017 |
| BIS | OT | ISSUED | Design Tech Construction | 07/01/2016 |
| BIS | PL | ISSUED | Top Dog Plumbing & Heating | 10/22/2015 |
| BIS | SP | ISSUED | Case Plumbing | 10/22/2015 |
| BIS | OT | ISSUED | Euda Construction | 10/16/2015 |
| BIS | PL | ISSUED | Pasquale Quaratino | 07/21/2015 |
| BIS | PL | ISSUED | Donato | 07/31/2012 |
| BIS | OT | ISSUED | Design Tech Construction | 07/05/2012 |
| BIS | PL | ISSUED | Pasquale Quaratino | 02/13/2004 |
| BIS | OT | ISSUED | Owner | 01/13/2004 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/12/2025 | — | — | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric PKFY-P08NLMU-E 27,000 BTU · Vrf Indoor ×3 MXZ-SM36NAM2 41,000 BTU · Condensing Unit ×1 PKFY-P12NLMU-E 13,500 BTU · Vrf Indoor ×1 |
| 06/09/2025 | Permit Issued | Ice Age Mechanical | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MXZ-SM60NAM 66,000 BTU · Condensing Unit ×1 PKFY-P06NLMU-E 191 CFM · Vrf Indoor ×1 PKFY-P08NLMU-E 237 CFM · Vrf Indoor ×1 PKFY-P12NLMU-E 295 CFM · Vrf Indoor ×1 PKFY-P24NKMU-E2 920 CFM · Vrf Indoor ×1 |
| 06/06/2025 | Permit Issued | Ice Age Mechanical | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric PKFY-P08NLMU-E 9,000 BTU · Vrf Indoor ×2 MXZ-SM60NAM 66,000 BTU · Condensing Unit ×1 PKFY-P06NLMU-E 5,700 BTU · Vrf Indoor ×1 PKFY-P12NLMU-E 13,500 BTU · Vrf Indoor ×1 PKFY-P18NLMU-E 20,000 BTU · Vrf Indoor ×1 |
| 01/07/2025 | Permit Issued | HBH Construction | Air Conditioning Systems | Cooling Mitsubishi Electric PKFY-P06NLMU-E 191 CFM · Vrf Indoor ×2 PKFY-P12NLMU-E 295 CFM · Vrf Indoor ×2 MXZ-SM48NAM 54,000 BTU · Condensing Unit ×2 PKFY-P18NLMU-E 438 CFM · Vrf Indoor ×1 MSZ-GL12NA-U1 295 CFM · Split System ×2 MSZ-GS06NA-U1 191 CFM · Split System ×2 MSZ-GL18NA-U1 438 CFM · Split System ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/19/2026 | Signed-off | Safepipe Plumbing | Water/Sanitary |
| 05/16/2024 | — | — | Gas, Water/Sanitary |
| 01/31/2023 | Signed-off | T&T Plumbing | Gas |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/30/2026 | Complete | V-Tech Electrical | General Wiring |
| 05/11/2026 | Complete | V-Tech Electrical | HVAC Wiring |
| 04/16/2026 | Permit Issued | V-Tech Electrical | HVAC Wiring |
| 04/09/2026 | Permit Issued | Kwong Ming Electric | General Wiring |
| 03/11/2026 | Complete | Kenneth Fisk Electric | General Wiring |
| 01/09/2026 | Complete | Denmar Electric | General Wiring |
| 12/18/2025 | Permit Issued | Roger de Electric Co | HVAC Wiring |
| 04/09/2025 | Complete | A.L. Electrical | General Wiring |
| 12/02/2024 | Complete | Denmar Electric | General Wiring |
| 08/28/2023 | Complete | FSM Electrical | General Wiring |
| 12/07/2020 | Complete | Lebo Electric | — |
| 03/12/2019 | Complete | Sunbird Electrical Contracting | General Wiring |
| 07/23/2018 | Complete | Vertex Electric | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/15/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 07/13/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/23/2026 | Fail-Final Sign Permit Inspection | Fail | View ↗ |
| 01/31/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 01/27/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/21/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/06/2026 | Lighting in dwelling units | Chang Park | energy_progress |
| 03/06/2026 | Fire-Resistant Penetrations and Joints | Chang Park | special |
| 03/06/2026 | Final | Chang Park | progress |
| 03/06/2026 | Lighting controls | Chang Park | energy_progress |
| 03/06/2026 | Interior lighting power | Chang Park | energy_progress |
| 08/15/2025 | Mechanical Systems | ERIC BERLENT | special |
| 08/15/2025 | Maintenance information | ERIC BERLENT | energy_progress |
| 08/15/2025 | HVAC-R and service water heating equipment | ERIC BERLENT | energy_progress |
| 08/15/2025 | HVAC-R and service water piping design and insulation | ERIC BERLENT | energy_progress |
| 08/15/2025 | HVAC-R and service water heating system controls | ERIC BERLENT | energy_progress |
| 08/15/2025 | Energy Code Compliance Inspections | ERIC BERLENT | progress |
| 08/15/2025 | Final | ERIC BERLENT | progress |
| 08/15/2025 | Fire-Resistant Penetrations and Joints | ERIC BERLENT | special |
| 05/20/2025 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 05/20/2025 | HVAC-R and service water heating system controls | — | energy_progress |
| 05/20/2025 | Mechanical Systems | — | special |
| 05/20/2025 | Post-installed Anchors | — | special |
| 05/20/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 05/20/2025 | Final | — | progress |
| 05/20/2025 | Maintenance information | — | energy_progress |
| 05/20/2025 | HVAC-R and service water heating equipment | — | energy_progress |
| 05/14/2025 | Maintenance information | MOLLY GLENN | energy_progress |
| 05/14/2025 | HVAC-R and service water heating system controls | MOLLY GLENN | energy_progress |
| 05/14/2025 | HVAC-R and service water heating equipment | MOLLY GLENN | energy_progress |
| 05/14/2025 | Energy Code Compliance Inspections | — | progress |