← Back
Miscellaneous two family
420 55 STREET
BROOKLYN · Sunset Park (West) · BIN 3014942
💬 Discuss this project
1896Year Built
2Stories
B9Building Class
R6BZoning
3,004 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Miscellaneous two family · 2,003 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 21p · 1 filing · 9 docs
Floor 1
Cellar1p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/24/2020$1.4M—— → —$466/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAREK TRESKO ARCHITECT, LLC504/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DEZIGNPLUS503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREGG NY PLUMBING, INCPlumbing507/08/2026
HOME BUYER GROUP CORPGeneral Contractor407/08/2026
KINGS ELECTRIC CO INC 002683General Contractor303/22/2026
RICHAIR MECHANICAL INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAREK TRESKO ARCHITECT, L1086305/12/2021
Building Lifecycle
All (26)Filed (5)Permit Issued (4)Signed Off (4)Violation (1)Inspection (5)Objection (2)Special Inspection (5)
06/24/2022
Signed off — Alteration
B00459017-I1
06/24/2022
Signed off — Alteration
in conjunction with renovation with existing 2 family house, structural work for the rear yard steel deck,
B00518420-I1
06/24/2022
Signed off — Alteration
B00488019-I1
06/08/2022
Signed off — Alteration
in conjunction with renovation of existing 2 family house. Plumbing work only.
B00488012-I1
06/03/2022
Permit issued — Structural
B00518420-I1-ST
05/26/2022
Permit issued — Mechanical Systems
B00488019-I1-MS
04/14/2022
Filed — Alteration
in conjunction with renovation of existing 2 family house. Plumbing work only.
B00488012-P1
02/09/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/29/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/29/2021
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/29/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/26/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/01/2021
Permit issued — Plumbing
B00488012-I1-PL
06/24/2021
Permit issued — General Construction
B00459017-I1-GC
05/13/2021
Objection raised — Inspections
05/13/2021
Objection resolved — Addressed
05/12/2021
Filed — Alteration
in conjunction with renovation with existing 2 family house, structural work for the rear yard steel deck,
B00518420-I1
05/12/2021
Special inspection requirement — Concrete - Cast-In-Place
Jarek Tresko
05/12/2021
Special inspection requirement — Structural Cold-Formed Steel
Jarek Tresko
05/12/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jarek Tresko
05/11/2021
Filed — Alteration
B00459017-I1
05/11/2021
Filed — Alteration
B00488019-I1
05/11/2021
Filed — Alteration
in conjunction with renovation of existing 2 family house. Plumbing work only.
B00488012-I1
05/11/2021
Special inspection requirement — Structural Steel - Details
Jarek Tresko
05/07/2021
Special inspection requirement — Final
Jarek Tresko
10/21/2016
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offHOME BUYER GROUP CORP06/03/2022
DOB NOWMechanical SystemsSigned-offRICHAIR MECHANICAL INC05/26/2022
DOB NOWPlumbingSigned-offGREGG NY PLUMBING, INC07/01/2021
DOB NOWGeneral ConstructionSigned-offHOME BUYER GROUP CORP06/24/2021
1 project · most recent 02/09/2022
General Wiring
FiledStatusContractorScope
02/09/2022CompleteKINGS ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/09/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/29/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/29/2021Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/29/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/26/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/12/2021Concrete - Cast-In-PlaceJarek Treskospecial
05/12/2021Structural Cold-Formed SteelJarek Treskospecial
05/12/2021Structural Stability – Alterations of existing buildingsJarek Treskospecial
05/11/2021Structural Steel - DetailsJarek Treskospecial
05/07/2021FinalJarek Treskoprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch4
09/01/2026B00488012-I1Request digital key ↗
09/01/2026B00488012-P1Request digital key ↗
09/01/2026B00488019-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - General Construction1
09/01/2026B00459017-I1Request digital key ↗
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/15/2026B00518420-I1Open ↗
08/13/2026B00488012-P1Open ↗
08/13/2026B00488012-I1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/01/2026B00488012-P1Open ↗
09/01/2026B00488012-I1Open ↗
09/01/2026B00459017-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00518420-I1Open ↗
09/01/2026B00518420-I1Open ↗
09/01/2026B00518420-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026B00518420-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026B00488012-I1Open ↗
09/01/2026B00488012-P1Open ↗
09/01/2026B00459017-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00459017-I1Open ↗
08/13/2026B00488019-I1Open ↗